1. Producte acabatview
The Eastron SDM630Modbus V3 is an advanced multi-function three-phase energy monitoring solution. It is designed for measuring and displaying various electrical parameters in 1-phase 2-wire, 3-phase 3-wire, and 3-phase 4-wire systems. This device is equipped with optional outputs such as pulses and RS485 RTU Modbus communication, making it suitable for integration into PV solar systems and other energy management applications.
It features configuration and display buttons for easy navigation through parameters and settings. The unit is housed for DIN rail mounting and offers IP51 protection. It supports direct connection up to 100A and allows for selectable measurement modes using free configuration software for kWh display, including Total kWh (Import + Export), Import kWh, and Net kWh (Export - Import).

Figura 1: Frontal view of the SDM630Modbus V3
2. Característiques clau
- Max. 100A Direct Load
- 4 Module (72mm wide) DIN rail mounting
- Bi-directional Measurement
- 2 Pulse outputs + RS485 Modbus communication
- Multi-measurement capabilities: kWh, kvarh, W, Var, VA, PF, Hz, dmd, V, A, etc.
- Compatible with 3P4W, 3P3W, and 1P2W systems
- Temperatura de funcionament: -25 a +55 graus centígrads
- Voltage: 230 V AC
- Accuracy Class: Cl. 1
- Measuring Energy Range: 0-999999.99 kWh
- Tipus de pantalla: LCD
- Protocol de comunicació: Modbus RTU
- Pulse Output 1: Configurable
- Pulse Output 2: 400imp/kWh (Passive type)
3. Instal·lació i configuració
3.1 Precaucions de seguretat
- La instal·lació només l'ha de fer personal qualificat.
- Assegureu-vos que tot l'alimentació estigui desconnectada abans de la instal·lació o el manteniment.
- Seguiu els codis elèctrics i les normatives locals.
- No feu funcionar el dispositiu si sembla que està danyat.
3.2 Muntatge
The SDM630Modbus V3 is designed for DIN rail mounting. Securely attach the device to a standard 35mm DIN rail within an appropriate enclosure, ensuring adequate ventilation.

Figura 2: lateral view illustrating DIN rail mounting
3.3 Esquema de cablejat
The meter supports 1-phase 2-wire, 3-phase 3-wire, and 3-phase 4-wire connections. Refer to the diagram below for correct wiring. Ensure all connections are tight and secure.

Figure 3: Wiring Diagram and Dimensions. The diagram shows connections for 1-phase 2-wire, 3-phase 3-wire, and 3-phase 4-wire systems. For 3-phase 4-wire, L1, L2, L3, and N are connected to terminals 1, 4, 7, and 10 respectively, with corresponding load connections on terminals 3, 6, 9, and 12. RS485 A and B are connected to terminals 13 and 14. Pulse outputs are on terminals 15 and 16.
Notes de cablejat:
- Entrada d'alimentació: Connect the phase and neutral wires according to the diagram for your specific system (1P2W, 3P3W, or 3P4W). The meter supports direct connection up to 100A.
- Comunicació RS485: Connect the RS485 A and B lines to terminals 13 and 14 respectively for Modbus RTU communication.
- Sortides de pols: Pulse output 1 and 2 are available on terminals 15 and 16. These are passive outputs.
4. Funcionament
The SDM630Modbus V3 features an LCD display and several buttons for navigating and configuring the device.
4.1 Pantalla i botons
The LCD displays various electrical parameters. The buttons (U/I, M, P, E) allow users to cycle through measurements, access menus, and confirm selections.
- Botó U/I: Typically used to cycle through voltage (U) and current (I) readings, or other instantaneous parameters.
- Botó M: Likely serves as a 'Mode' or 'Menu' button to access different measurement screens or configuration settings.
- Botó P: May be used for 'Parameter' selection or 'Pulse' related settings.
- Botó E: Generally functions as an 'Enter' or 'Exit' button to confirm selections or leave a menu.
For detailed navigation and configuration, refer to the official datasheet and configuration software manual available on the Eastron weblloc.
4.2 Modes de mesura
The device can measure a wide range of parameters including:
- Active Energy (kWh) - Total, Import, Export, Net
- Reactive Energy (kvarh)
- Potència activa (W)
- Reactive Power (Var)
- Potència aparent (VA)
- Factor de potència (PF)
- Freqüència (Hz)
- Voltage (V)
- Corrent (A)
- Demand (dmd)
- I més.
Specific measurement modes and their display can be configured using the provided software.
5. Manteniment
The SDM630Modbus V3 is designed for reliable operation with minimal maintenance. However, periodic checks are recommended:
- Neteja: Mantingueu el dispositiu net i lliure de pols. Feu servir un drap suau i sec per netejar-lo. No utilitzeu productes de neteja abrasius ni dissolvents.
- Connexions: Periodically inspect all wiring connections to ensure they remain tight and secure. Loose connections can lead to inaccurate readings or device malfunction.
- Medi ambient: Assegureu-vos que l'entorn de funcionament es mantingui dins dels rangs de temperatura i humitat especificats per evitar danys.
6. Solució De Problemes
If you encounter issues with your SDM630Modbus V3, consider the following troubleshooting steps:
- Sense pantalla/alimentació:
- Check the main power supply to the meter.
- Verify all power connections are correctly wired and secure.
- Lectures inexactes:
- Ensure the wiring configuration matches your electrical system (1P2W, 3P3W, 3P4W).
- Check for loose or incorrect wiring connections.
- Verify that the meter's settings (e.g., CT ratio if applicable, though this model is direct connect up to 100A) are correctly configured.
- Communication Issues (RS485 Modbus):
- Check RS485 A and B connections for correct polarity and secure fit.
- Verify the Modbus address, baud rate, parity, and stop bits settings on both the meter and the master device.
- Ensure the communication cable length does not exceed the maximum recommended distance (1000m).
If problems persist, consult the official datasheet or contact Eastron technical support.
7. Especificacions
Detailed technical specifications for the SDM630Modbus V3 are provided below.

Figura 4: Paràmetres detallats del producte
| Paràmetre | Valor |
|---|---|
| Nom de marca | Eastron |
| Número de model | SDM630Modbus V3 |
| Dimensions | 100 * 72 * 66 mm |
| Temperatura de funcionament | -25 a +55 graus centígrads |
| Vol. De sortidatage | 230 V |
| Classe de precisió | Cl. 1 |
| Mesura del rang d'energia | 0-999999.99 kWh |
| Fase | Trifàsica |
| Corrent màxim de funcionament | 100A (Direct Load) |
| Voltage | 230 V |
| Font d'alimentació | AC |
| Tipus de visualització | LCD |
| Subministraments de bricolatge | Elèctric |
| Tipus de comunicació | RS485 |
| Protocol de comunicació | Modbus RTU |
| Sortida de pols 1 | Configurable |
| Sortida de pols 2 | 400 imp/kWh |
| Tipus de sortida d'impulsos | Passiva |
Electrical Characteristics (from image)
| Tipus de mesura | Precisió |
|---|---|
| Poder | 0.5% del rang màxim |
| Energia activa | IEC 62053-21 Classe 1.0 |
| Energia reactiva | IEC62053-23 Classe 2 |
| Freqüència | 0.2% de freqüència mitjana |
| Actual | 0.5% del rang màxim |
| Voltage | 0.5% del rang màxim |
| Factor de potència | 1% de la unitat (0.01) |
Input & Output (from image)
| Paràmetre | Valor |
|---|---|
| Corrent nominal (Ib/Iref) | 10A |
| Max Current (Imax.) | 100A |
| Min Current (Imin.) | 0.5A |
| Corrent d'arrencada | 40 mA |
| Voltage (Un) | 230V L-N / 120V L-N |
| Vol operatiutage | 80%~120% de la Un |
| Sortida | 2 sortides d'impulsos + RS485 Modbus |
Ethernet Communication (from image)
| Paràmetre | Valor |
|---|---|
| Tipus d'autobús | RS485 (semi-duplex) |
| Adreça de comunicació | 1~247 |
| Distància de transmissió | 1000m màxim |
| Velocitat de transmissió | 2400bps~38400bps |
| Paritat | Cap (per defecte), Impar, Parell |
| Stop Bits | 1 |
8. Garantia i Suport
8.1 Informació de la garantia
The Eastron SDM630Modbus V3 comes with an 18-month warranty from the date of purchase.
8.2 Suport tècnic i recursos
- Full de dades: A detailed datasheet for the SDM630Modbus V3 can be downloaded from the official Eastron weblloc: www.eastrongroup.com.
- Modbus Protocol Instruction / Register Map: For specific Modbus protocol instructions and register maps, please contact Eastron directly.
- Consultes generals: For any further questions or support, please contact Eastron customer service.

Figura 5: Preguntes freqüents
9. Consells d'usuari
- Compatibilitat de l'inversor: The SDM630Modbus V3 has been reported by users to be compatible with Deye Inverters. Always verify specific model compatibility with your inverter manufacturer or Eastron support if unsure.
- Configuració del programari: Utilize the free configuration software provided by Eastron to customize measurement modes and display settings for optimal performance in your specific application.