The Andonstar AD269S is a newly upgraded multifunctional digital microscope designed for a wide range of applications, from observing biological slides to inspecting circuit boards and coins. Featuring a 10.1-inch UHD 2160P IPS LCD monitor, a robust metal stand, and a versatile 5-lens system including an endoscope, it offers magnifications up to 5000X. This manual provides detailed instructions for setting up, operating, and maintaining your AD269S digital microscope to ensure optimal performance and longevity.

2. Contingut del paquet
Si us plau, verifiqueu que tots els elements que s'enumeren a continuació estiguin inclosos al vostre paquet:
- Microscope Unit (with 10.1-inch LCD monitor) ×1
- Lens A (18X-720X) ×1
- Lens B&C (1560X-4080X) ×1
- Lens L (60-240X) ×1
- Lens M (3600-5100X) ×1
- Adjustable Arm ×1
- Base × 1
- Column ×1
- External LED Lights ×1
- XY mòbil Stage × 1
- Backdrop Boards ×3
- Control remot × 1
- Adaptador d'alimentació × 1
- Cable HDMI × 1
- Cable USB × 1
- Dimmer Cable ×1
- Biological Slides Kit ×1
- Tweezers ×1
- Observe Box ×1
- Manual d'usuari × 1
- 32GB SD Card ×1
- Endoscope ×1
- Endoscope Accessories ×1

3. Especificacions
| Característica | Detall |
|---|---|
| Material | Metall |
| Color | Negre |
| Mida de la pantalla | LCD IPS de 10.1 polzades |
| Sensor d'imatge | 4 Mega Pixels High Definition Sensor |
| Sortida de vídeo | UHD 2880*2160 24FPS; FHD 1920*1080 60FPS/30FPS; HD 1280*720 120FPS |
| Format de vídeo | MP4 |
| Relació d'ampliació | Up to 5000X (on a 27-inch HDMI monitor) |
| Resolució fotogràfica | Max. 5600*4200 (24M) |
| Format fotogràfic | JPG |
| Distància mínima d'enfocament | 0.5 mm |
| Velocitat de fotogrames | Max. 120f/s (under 600 lux brightness & HD 120FPS) |
| Emmagatzematge | Micro-SD card, up to 32GB (32GB card included) |
| Suport de PC | Sí |
| Font d'alimentació | 5V DC |
| Mida de l'estand | 20 cm x 19 cm x 40 cm |
| Bateria de control remot | 2 * piles AAA (no incloses) |
| Pes del paquet | 3.3 kg |
Lens Specifications:
| Tipus de lent | Ampliació | Distància d'observació | Aplicacions |
|---|---|---|---|
| Lent A | 18X-720X | 12 mm-320 mm | Whole or part coins, stones, circuit boards, etc. |
| Lens B&C | 1560X-4080X | 3 mm-8 mm | Microscope slides, biological samples, etc. |
| Lent L | 60-240X | 90 mm-300 mm | PCB soldering, circuit board inspection, repairing, etc. |
| Lens M | 3600-5100X | 0.5 mm-0.7 mm | Microscope slides, highly detailed biological samples, etc. |


4. Guia de configuració
Follow these steps to assemble and prepare your Andonstar AD269S Digital Microscope for use:
- Muntar el suport: Attach the column to the base, then secure the adjustable arm to the column. Ensure all connections are tight and stable. The metal stand provides enhanced stability, crucial for high magnification work.
- Muntar la unitat de microscopi: Carefully attach the microscope unit (with the integrated 10.1-inch LCD monitor) to the adjustable arm. Adjust the viewing angle of the monitor as needed.
- Install the X-Y Moveable Stage: Place the X-Y moveable stage onto the microscope base. This stage allows for precise positioning of your samples.
- Connect External LED Lights: Attach the external LED lights to the designated ports on the microscope. Use the dimmer cable to control their brightness.
- Inseriu la targeta SD: Locate the Micro-SD card slot on the microscope unit and insert the provided 32GB SD card. This is essential for saving photos and videos.
- Connectar l'alimentació: Plug the power adapter into the microscope unit and then into a suitable power outlet (5V DC).
- Connecteu una lent: Select the appropriate lens (A, B&C, L, or M) for your observation needs and screw it onto the microscope objective. Refer to the lens specifications for guidance.
- Connect Endoscope (Optional): If using the endoscope, connect it to the designated port. Note that the endoscope does not support PC output.


5. Instruccions de funcionament
5.1 Encès/Apagat
- Press the power button on the microscope unit to turn it on. The LCD screen will illuminate.
- Per apagar-lo, premeu i manteniu premut el botó d'engegada fins que la pantalla s'apagui.
5.2 Lens Selection and Usage
The AD269S comes with a versatile 5-lens system. Choose the appropriate lens based on your observation needs:
- Lens A (18X-720X): Ideal for observing larger objects like entire coins, stones, or general circuit board inspection. Offers a wider field of view and longer working distance.
- Lens L (60-240X): Specifically designed for tasks requiring a medium working distance, such as PCB soldering, repairing, and detailed circuit board examination.
- Lens B&C (1560X-4080X) & Lens M (3600-5100X): These lenses provide very high magnification for microscopic observation of biological slides and other fine details. They require a very short working distance.
5.3 Focusing and Stage Moviment
- Col·loca el teu sample on the X-Y moveable stage.
- Adjust the height of the microscope head using the coarse adjustment knob until the sample is roughly in focus.
- Use the fine adjustment knob for precise focusing.
- Utilize the X-Y stage adjustment knobs to move the sample horizontally and vertically across the field of view.
5.4 Ajust de la il·luminació
- The external LED lights provide illumination for your samples.
- Use the dimmer cable to adjust the brightness of the LED lights to achieve optimal viewcondicions.
5.5 Captura de fotos i vídeos
- The 10.1-inch IPS LCD monitor displays a clear, high-definition image.
- To capture a photo, press the 'Photo' button on the microscope unit or remote control. Photos are saved in JPG format at up to 24MP resolution.
- To record a video, press the 'Record' button. Press it again to stop recording. Videos are saved in MP4 format at resolutions up to UHD 2160P.
- All captured media is stored on the inserted Micro-SD card.

5.6 PC and HDMI Output
- Sortida HDMI: Connect the microscope to an external monitor or TV using the provided HDMI cable for a larger display (FHD 1920x1080 output).
- PC Output: Connect the microscope to a computer via the USB cable. Install the necessary PC software (usually found on the included SD card or manufacturer's weblloc) a view the live feed and utilize measurement functions. Note: The endoscope does not support PC output.

5.7 Endoscope Usage
- The auxiliary endoscope allows for inspection in hard-to-reach areas or for objects that cannot be placed on the stage.
- Connect the endoscope to its dedicated port on the microscope unit.
- Adjust the endoscope's focus and position to view the desired area on the microscope's screen.

5.8 Control remot
- The included remote control allows for hands-free operation, reducing vibrations during photo/video capture.
- Introduïu 2 piles AAA (no incloses) al comandament a distància.
- Use the remote to control functions such as power, photo capture, video recording, and menu navigation.
6. Manteniment
- Neteja de lents: Use a soft, lint-free cloth and lens cleaning solution specifically designed for optical equipment. Avoid touching the lens surfaces with bare hands.
- Neteja de la pantalla: Wipe the LCD screen with a soft, dry microfiber cloth. For stubborn smudges, use a screen cleaner.
- Neteja general: Keep the microscope body and stand free of dust and debris. Use a soft brush or compressed air for hard-to-reach areas.
- Emmagatzematge: When not in use, store the microscope in a clean, dry place, preferably covered with a dust cover to protect it from environmental elements.
- Cura de la bateria: If using the remote control, remove the AAA batteries if the device will not be used for an extended period to prevent leakage.
7. Solució De Problemes
7.1 No hi ha imatge a la pantalla
- Ensure the power adapter is securely connected and the microscope is turned on.
- Check if the selected lens is properly attached and clean.
- Adjust the focus and illumination.
7.2 Imatge borrosa
- Adjust the coarse and fine focus knobs carefully.
- Assegureu-vos que el sample is flat on the stage and the lens is clean.
- Verify that the correct lens is being used for the desired magnification and working distance.
7.3 SD Card Not Recognized / Cannot Save
- Assegureu-vos que la targeta SD estigui inserida correctament i completament.
- Check if the SD card is locked (physical switch on the card).
- Try formatting the SD card through the microscope's menu (this will erase all data).
- Test with a different compatible Micro-SD card.
7.4 No Output to External Monitor/PC
- For HDMI, ensure the HDMI cable is securely connected to both the microscope and the external display, and the display input is set to the correct HDMI port.
- For PC, ensure the USB cable is connected, the PC software is installed, and the microscope is in PC mode (if applicable). Remember the endoscope does not support PC output.
8. Consells d'usuari
- Start with Lower Magnification: When observing a new sample, always start with a lower magnification lens (e.g., Lens A) to locate the area of interest, then switch to higher magnification lenses for detailed examination.
- Optimització de la il·luminació: Experiment with the external LED lights and dimmer to find the best illumination for your sample. Proper lighting can significantly improve image clarity and contrast.
- Use the X-Y Stage: For precise movements, especially at high magnifications, always use the X-Y moveable stage. Manual adjustments can cause the sample to move out of the field of view.
- Calibrate for Measurements: If using the PC software for measurements, ensure you perform proper calibration according to the software's instructions for accurate results.
- Superfície estable: Always place the microscope on a stable, level surface to prevent vibrations that can affect image quality, especially at high magnifications.
9. Garantia i Suport
The Andonstar AD269S Digital Microscope is covered by a manufacturer's warranty against defects in materials and workmanship. For specific warranty terms, duration, and to obtain technical support or service, please refer to the warranty card included in your package or contact Andonstar customer service directly. Keep your purchase receipt as proof of purchase.