Introducció
This manual provides essential information for the proper installation, maintenance, and understanding of the Panasonic CWH361120 installation plate. This plate is designed to securely mount specific Panasonic internal air conditioner units to a wall, ensuring stable and efficient operation of your air conditioning system. Please read these instructions carefully before proceeding with installation.
Configuració i instal·lació
The CWH361120 installation plate serves as the foundational mounting bracket for your Panasonic internal air conditioner unit. Proper installation is crucial for the safety and performance of the AC unit. It is highly recommended that installation be performed by a qualified professional.
Passos generals d'instal·lació:
- Selecció del lloc: Choose a wall location that is structurally sound, free from obstructions, and allows for proper air circulation around the indoor unit. Ensure there is adequate space for refrigerant piping and drainage.
- Positioning the Plate: Hold the installation plate against the chosen wall location. Use a level to ensure it is perfectly horizontal. Mark the drilling points through the designated holes on the plate.
- Perforació: Drill holes at the marked positions. The size of the drill bit should match the wall anchors or screws being used.
- Securing the Plate: Insert wall anchors (if required) and then firmly attach the installation plate to the wall using appropriate screws. Ensure the plate is securely fastened and does not wobble.
- Piping and Wiring Preparation: Before mounting the indoor unit, ensure that the refrigerant lines, drainage pipe, and electrical wiring are correctly routed through the wall opening and are ready for connection to the indoor unit. The plate provides structural support for these connections.
- Muntatge de la unitat interior: Carefully lift the indoor unit and hook it onto the top tabs of the installation plate. Gently push the bottom of the unit towards the wall until it clicks into place, securing it to the lower part of the plate.
- Comprovacions finals: Verify that the indoor unit is securely mounted, level, and that all connections (refrigerant, drainage, electrical) are properly made and sealed according to the main AC unit's instructions.

Informació operativa
The CWH361120 installation plate is a passive component designed to provide structural support for your air conditioner. It does not have any operational controls or functions itself. Its primary role is to ensure the indoor unit is securely and correctly positioned, which is essential for the safe and efficient operation of the entire air conditioning system. Refer to your Panasonic air conditioner unit's specific user manual for operating instructions.
Manteniment
The installation plate itself requires minimal maintenance. During routine maintenance of your air conditioner unit, consider the following:
- Inspecció visual: Periodically check the plate and its mounting screws for any signs of loosening, corrosion, or damage. Ensure the indoor unit remains securely attached to the plate.
- Neteja: If the plate becomes dusty or dirty during AC unit servicing, wipe it clean with a dry or slightly damp tela. Eviteu utilitzar productes químics aggressivs o netejadors abrasius.
- Verificació professional: During professional AC servicing, ask the technician to verify the integrity of the installation plate and its mounting.
Resolució de problemes
Issues directly related to the installation plate are typically structural. If you experience any of the following, inspect the plate and its mounting:
- Indoor Unit Wobbling: If the indoor unit feels loose or wobbles on the wall, the installation plate may not be securely fastened, or the unit may not be correctly seated on the plate.
- Vibració excessiva: While AC units produce some vibration, excessive or unusual vibration from the indoor unit could indicate an unstable mounting.
- Danys visibles: Any cracks, bends, or corrosion on the plate should be addressed immediately.
In case of any structural concerns, it is recommended to contact a qualified HVAC technician for inspection and repair.
Especificacions
| Característica | Detall |
|---|---|
| Número de model | CWH361120 |
| Tipus de producte | Installation Plate for Internal Air Conditioner Unit |
| Marques compatibles | Panasonic |
| Dimensions del paquet (aprox.) | 15 cm (llarg) x 10 cm (ample) x 7 cm (alçada) |
| Pes del paquet (aprox.) | 1.0 kg |
Compatible Internal Air Conditioner Unit Models:
- Cs-le12nkd
- Cs-le9nkd
- Cs-mye12pkz
- Cs-mye15pkz
- Cs-mye18pkz
- Cs-mye7pkz
- Cs-mye9pkz
- Cs-re12pkv71
- Cs-re9pkv-7
- Cs-yc12mkv
- Cs-yc12mkv-6
- Cs-yc12mkv-7
- Cs-yc12nkv-6
- Cs-yc12nkv61
- Cs-yc9mkv
- Cs-yc9mkv-6
- Cs-yc9mkv-7
- Cs-ye12mka
- Cs-ye12mke
- Cs-ye12mkv-6
- Cs-ye12mkv-7
- Cs-ye12mkx
- Cs-ye12nkv-6
- Cs-ye12pky
- Cs-ye18mke
- Cs-ye18mkx
- Cs-ye18pky
- Cs-ye9mka
- Cs-ye9mke
- Cs-ye9mkv-7
- Cs-ye9mkx
- Cs-ye9pky
- Cs-yw12mkd
- Cs-yw12mkd-1
- Cs-yw7mkd
- Cs-yw7mkd-1
- Cs-yw9mkd
- Cs-yw9mkd-1
Consells per a l'usuari
- Always verify the compatibility of the installation plate with your specific Panasonic indoor unit model before beginning installation.
- Ensure the wall material is appropriate for supporting the weight of the air conditioner unit and the installation plate. Use suitable fasteners for your wall type (e.g., concrete anchors, wood screws).
- Double-check that the plate is perfectly level to prevent drainage issues and ensure optimal performance of the AC unit.
Garantia i Suport
For warranty information regarding your Panasonic CWH361120 installation plate, please refer to the documentation provided with your main Panasonic air conditioner unit or contact Panasonic customer support directly. As an accessory, its warranty may be tied to the primary appliance. For technical assistance or support, please reach out to an authorized Panasonic service center or a certified HVAC professional.





