NJTY T400/T400A/T600/T600A

NJTY Infrared Thermometer User Manual

Models: T400, T400A, T600, T600A

1. Introducció

This manual provides detailed instructions for the safe and effective use of your NJTY Infrared Thermometer. These non-contact thermometers are designed for quick and accurate temperature measurement across various applications, including industrial, kitchen, and general household use. Please read this manual thoroughly before operation and retain it for future reference.

Two NJTY infrared thermometer models, T400 and T400A/T600 and T600A, side-by-side

NJTY Multi-function Infrared Thermometer (T400/T600 with fixed emissivity, T400A/T600A with adjustable emissivity)

Característiques principals:

  • 0.5-second rapid response time
  • Laser positioning for precise targeting
  • One-touch measurement operation
  • Audio-visual alert system with backlight
  • Switchable temperature units (Celsius and Fahrenheit)
  • Vol baixtage indicació
  • Funció d'apagada automàtica
  • Compact size and comfortable grip
  • High-definition backlit display for visibility in dark conditions

Important Safety Note: This device is not suitable for measuring human or animal body temperature.

2. Configuració

2.1 Contingut del paquet

Si us plau, comproveu el paquet per assegurar-vos que hi hagi tots els components:

  • NJTY Infrared Thermometer (T400, T400A, T600, or T600A model)
  • Manual d'usuari

Nota: Les piles AAA no estan incloses i s'han de comprar per separat.

2.2 Instal·lació de la bateria

  1. Locate the battery lock latch at the bottom of the handle.
  2. Feu lliscar el pestell per obrir el compartiment de la bateria.
  3. Introduïu dues (2) piles AAA, assegurant-vos de la polaritat correcta (+/-).
  4. Close the battery compartment by sliding the latch back into place until it clicks securely.
Image showing the battery compartment of the thermometer with two AAA batteries being inserted.

Compartiment de piles per a 2 piles AAA

2.3 Dispositiu acabatview

Familiarize yourself with the main components of your thermometer:

Diagram labeling the parts of the infrared thermometer: Temperature sensing area, Infrared laser point, Laser point switch, Measurement board machine, Display screen, Backlight button, Celsius/Fahrenheit Switch button, Battery lock latch.

Infrared Thermometer Components

  • Temperature Sensing Area: The infrared sensor that detects temperature.
  • Infrared Laser Point: Emits a laser dot for targeting the measurement area.
  • Laser Point Switch: Button to activate/deactivate the laser.
  • Disparador de mesura: Press to take a temperature reading.
  • Pantalla de visualització: Shows temperature readings, unit, and other indicators.
  • Botó de retroil·luminació: Activates/deactivates the display backlight.
  • Celsius/Fahrenheit Switch Button: Toggles between °C and °F units.
  • Battery Lock Latch: Assegura el compartiment de la bateria.

3. Instruccions de funcionament

3.1 Prendre una mesura

  1. Point the thermometer at the object you wish to measure.
  2. Press and hold the measurement trigger. The laser pointer (if activated) will indicate the center of the measurement area.
  3. The temperature reading will appear on the display screen within 0.5 seconds.
  4. Release the trigger to hold the reading on the screen. The device will automatically shut down after a period of inactivity to conserve battery.
Hand holding the thermometer, showing the laser point and digital display with features highlighted.

Quick measurement with laser positioning

3.2 Switching Temperature Units

Press the '°C/°F' button to toggle between Celsius and Fahrenheit temperature units on the display.

Two thermometers displaying temperature in Celsius and Fahrenheit, illustrating the switchable measurement feature.

Celsius/Fahrenheit switchable measurement

3.3 Understanding Distance to Spot Ratio (D:S)

The thermometer has a Distance to Spot Ratio (D:S) of 12:1. This means that at a distance of 12 units, the measurement spot diameter will be 1 unit. For example, if you are 12 inches away from an object, the measurement area will be 1 inch in diameter. To ensure accurate readings, especially for smaller objects, measure from a closer distance. It is recommended not to exceed 1 meter for testing, as measuring from too far away may result in mixed temperature readings due to air and dust interference.

Diagram illustrating the 12:1 Distance to Spot Ratio (D:S) of the thermometer, showing how the measurement spot size increases with distance.

Distance to Spot Ratio (D:S = 12:1)

3.4 Configuració d'emissivitat

Emissivity is a measure of an object's ability to emit infrared energy. Different materials have different emissivity values. Models T400 and T600 have a fixed emissivity of 0.95, which is suitable for most organic materials and painted surfaces. Models T400A and T600A feature adjustable emissivity, allowing for more accurate measurements on a wider range of materials.

For models with adjustable emissivity, refer to the Emissivity Reference Table below to set the appropriate value for the material being measured. Adjusting emissivity ensures the most accurate temperature readings.

Table listing various substances and their corresponding emissivity values.

Taula de referència d'emissivitat

4. Manteniment

4.1 Neteja

  • Neteja de lents: Use a soft, clean cloth or cotton swab with water or medical alcohol. Wipe gently to avoid scratching the lens.
  • Neteja de l'habitatge: Netegeu la carcassa del dispositiu amb un anunciamp sponge or soft cloth and mild soap. Do not use abrasive cleaners or immerse the device in water.

4.2 Substitució de la bateria

Quan el vol baixtage indicator appears on the display, replace the batteries as described in Section 2.2. Always use two new AAA batteries of the same type.

4.3 Emmagatzematge

Store the thermometer in a cool, dry place away from direct sunlight, extreme temperatures, and high humidity. Remove batteries if the device will not be used for an extended period to prevent leakage.

5. Solució De Problemes

  • Cap pantalla/Dispositiu que no s'encén: Comproveu la instal·lació de les piles i assegureu-vos que no estiguin esgotades. Substituïu-les si cal.
  • Lectures inexactes:
    • Ensure the D:S ratio is respected; measure closer to the target for smaller objects.
    • For T400A/T600A models, verify the emissivity setting matches the material being measured.
    • Assegureu-vos que la lent estigui neta i lliure d'obstruccions.
    • Eviteu mesurar a través de vidre o altres superfícies transparents, ja que els termòmetres d'infrarojos mesuren la temperatura de la superfície del vidre.
    • Allow the thermometer to stabilize in the environment where it will be used if moving between areas with significant temperature differences.
  • Volum baixtage Indicació: Substituïu les piles AAA.
  • Apagat automàtic: This is a normal power-saving feature. The device will turn off after a period of inactivity.

6. Especificacions

The following table outlines the technical specifications for the NJTY T400, T400A, T600, and T600A infrared thermometer models:

Parameter table for NJTY T400 and T400A infrared thermometers.

Parameter Table for T400 and T400A Models

Parameter table for NJTY T600 and T600A infrared thermometers.

Parameter Table for T600 and T600A Models

Combined Technical Specifications
CaracterísticaT400 / T400AT600 / T600A
Interval de mesura-50 ~ 400 ° C (-58 ~ 752 ° F)-50 ~ 600 ° C (-58 ~ 1112 ° F)
Accuracy (≥0°C/32°F)±1.5°C (±2.7°F) or ±1.5%, whichever is greater
Accuracy (<0°C/32°F)±3°C (±5.4°F) or ±3%, whichever is greater
EmissivitatT400: preset to 0.95
T400A: adjustable
T600: preset to 0.95
T600A: adjustable
Valor màximN.A. (T400)
Checked (T400A)
N.A. (T600)
Checked (T600A)
Repetibilitat% of the reading or 1°C
Temps de resposta500 mSeg, resposta del 95%.
Longitud d'ona de resposta8-14 h
Temperatura de funcionament0-50 °C (32-122 °F)
Humitat d'emmagatzematge10-90% RH non-condensing (excluding batteries)
Font d'alimentacióAAA*2 batteries
Magnification Ratio (D:S)12:1
Pes net (sense les bateries)Aproximadament 122 grams
Gross Weight (including packaging)Aproximadament 166 grams
Dimensions (A x A x P)145 mm x 78 mm x 43 mm
Image showing the dimensions of the thermometer: 145mm height, 78mm width, 43mm depth.

Thermometer Dimensions

7. Garantia i Suport

For warranty information and technical support, please contact the seller or retailer from whom you purchased this product. Keep your purchase receipt as proof of purchase.

8. Consells d'usuari

  • Preparació de la superfície: For highly reflective surfaces (e.g., polished metals), consider applying a piece of masking tape or flat black paint to the surface and measuring the temperature of that spot for a more accurate reading.
  • Factors ambientals: Be aware that steam, dust, smoke, or other airborne particles can interfere with accurate infrared measurements. Try to measure in clear conditions.
  • Not for Internal Temperature: Remember, this device measures surface temperature. It is not designed for or accurate in measuring internal temperatures of objects or living beings.
  • Durada de la bateria: To maximize battery life, always turn off the laser pointer when not needed and utilize the automatic shutdown feature.

Documents relacionats - T400/T400A/T600/T600A

Preview Manual d'instruccions del termòmetre d'infrarojos NJTY T-600A
Manual d'instruccions del termòmetre d'infrarojos NJTY T-600A. Coneix les seves característiques, funcionament segur, relació distància-punt, configuració d'emissivitat, manteniment i especificacions tècniques per a una mesura precisa de la temperatura sense contacte.
Preview Multímetre analògic NJTY sèrie 88: manual d'usuari i guia tècnica
Manual d'usuari complet per als multímetres analògics de la sèrie NJTY 88, que cobreix les característiques, les especificacions, les precaucions de seguretat i les instruccions de mesura per a voltatges de CC/CA.tage i corrent, resistència, capacitança, freqüència i més.
Preview NJTY S18D Digital Multimeter User Manual
User manual for the NJTY S18D Digital Multimeter, detailing safety instructions, panel indications, operational guidelines, and technical specifications for accurate electrical measurements. Features include IEC-61010 compliance, backlit LCD, True RMS, and auto-ranging.
Preview Multímetre LCR NJTY T21L: Multímetre digital de rang automàtic amb TRUE RMS - Manual d'usuari
Manual d'usuari complet per al multímetre LCR NJTY T21L, un multímetre digital de rang automàtic amb TRUE RMS. Cobreix les especificacions, la seguretat, el funcionament i les funcions de mesura de vol.tage, corrent, resistència, capacitança, inductància, freqüència i temperatura.
Preview Multímetre LCR NJTY T21L: Multímetre digital de rang automàtic amb TRUE RMS - Manual d'usuari
User manual for the NJTY T21L LCR Meter, an auto-ranging digital multimeter with TRUE RMS. Covers features, safety, technical specifications, and operation for accurate electrical measurements.
Preview Guia de l'usuari del multímetre punter NJTY: característiques, especificacions i instruccions
Guia d'usuari completa per al multímetre punter NJTY, que detalla el seu aspecte, especificacions i funcions de mesura (volts CC/CA).tage, corrent, resistència, capacitança, etc.), i recordatoris importants de seguretat.