EARU EAEMP3C-100-TY-W

EARU EAEMP3C-100-TY-W 3 Phase Tuya WiFi Smart Energy Meter & Protector Instruction Manual

Brand: EARU | Model: EAEMP3C-100-TY-W

1. Introducció

The EARU EAEMP3C-100-TY-W is a smart 3-phase energy meter and protector designed for comprehensive electrical system management. It offers real-time monitoring of energy consumption, voltage, current, and frequency, along with advanced protection features against over/under voltage, over/under current, leakage, and high temperature. Integrated with Tuya WiFi, it allows for remote control and monitoring via a smartphone application, supporting voice control through Google Assistant and Amazon Alexa.

2. Informació de seguretat

WARNING: Installation must be performed by a qualified electrician. Disconnect power before installation or maintenance. Do not operate the device if it is damaged. Ensure proper grounding. Follow all local electrical codes and regulations.

3. Contingut del paquet

Verifiqueu que tots els elements siguin presents al paquet:

4. Especificacions

AtributValor
Número de modelEAEMP3C-100-TY-W
Voltage380 V CA
Operació VoltageAC80V-400V (Single Phase)
Freqüència nominal50Hz/60HZ
Corrent màxim de funcionament80A - 99A
Mesura del rang d'energia0-9999999.99 kWh
Classe de precisió1%
FaseTrifàsica
Font d'alimentacióAC
Tipus de visualitzacióLCD
Temperatura de funcionament-30 ℃ ~ 70 ℃
Dimensions90 * 77 * 75.5 mm
CertificacióCE, FCC, RoHS, KC
Més del voltage Límit120-300V (Adjustable) (Default:275V)
Sota el voltage Límit80-210V (Adjustable) (Default:175V)
Over Current Limit1-100A (Adjustable) (Default:80A)
Under Current Limit1-100A (Adjustable) (Default:10A)
Leakage Current Limit10-99A (Adjustable) (Default:29mA)
Alarma d'alta temperatura10℃-85℃ (Adjustable) (Default:85℃)
Mode de visualitzacióDisplay Mode 1 and 2 (Default:Display Mode 1)
Over & Under Voltage Protection Recovery Time1-9999s (Adjustable) (Default:20s)
Over & Under Current Protection Delay0000-9999s (Adjustable) (Default:5s)
Over & Under Current Protection Recovery Time0000-9999s (Adjustable) (Default:20s)
Under & Over Voltage Protection Delay1-9999s (Adjustable) (Default:3s)
Three-Phase Current Imbalance Alarm10-100% (Adjustable) (Default:20%)
Voltage Three-Phase Imbalance Alarm0-100% (Adjustable) (Default:20%)
Lost Current Recovery Delay Time1-9999s (Adjustable) (Default:20s)
Time Threshold of Lost Flow Event1-999s (Adjustable) (Default:10s)

5. Configuració

5.1 Dimensions físiques

Refer to the diagram below for the physical dimensions of the device and current transformer.

Dimensions of the EARU Smart Energy Meter and Current Transformer

Figure 5.1: Device and Current Transformer Dimensions

5.2 Esquema de cablejat

Follow the wiring diagram carefully for correct installation. Ensure all power is disconnected before proceeding.

Wiring diagram for the EARU 3 Phase Smart Energy Meter

Figura 5.2: Diagrama de cablejat

Note: One zero wire and three fire wires must pass through the current transformer at the same time. Otherwise, no leakage value can be detected.

Press down on the yellow button to insert the connector, then connect the connector to the transformer.

5.3 App Pairing (Tuya Smart / Smart Life)

To enable smart features, pair your device with the Tuya Smart or Smart Life application.

  1. Download the Tuya Smart or Smart Life app from your smartphone's app store.
  2. Registreu-vos o inicieu sessió al vostre compte.
  3. On the device, the WiFi indicator light will flash. Fast flashing indicates it's searching for a WiFi signal.
  4. In the app, tap 'Add Device' or the '+' icon. The app may automatically detect the device.
  5. If the device does not connect automatically, long-press the third key on the meter's screen (the one showing voltage) for three seconds to initiate pairing mode.
  6. Follow the on-screen instructions in the app to complete the pairing process, including entering your WiFi network credentials.
  7. Once successfully paired, the WiFi indicator light will be solid, and the device will appear in your app.

Video 5.1: Demonstration of App Pairing and Basic Operation

The app interface allows for monitoring and control. An example of the app's energy statistics and settings is shown below.

Tuya Smart app interface showing energy statistics and settings

Figure 5.3: Tuya Smart App Interface

6. Instruccions de funcionament

6.1 Modes de visualització

The device features an upgraded color screen with two main display modes:

Display modes of the smart energy meter showing various parameters

Figure 6.1: Device Display Modes

6.2 Funcions del temporitzador

The device supports three time setting modes via the app:

Examples of timing, countdown, and cycle time modes for smart control

Figure 6.2: Timer Setting Modes

6.3 Control remot i control per veu

Once paired with the Tuya Smart app, you can remotely control the device from anywhere. The device is also compatible with Google Assistant and Amazon Alexa for voice control commands.

7. Configuració d'alarma

The device offers various protection functions with adjustable alarm thresholds. The alarm function is automatically turned on after setting the threshold, and the protection tripping switch can be turned on or off.

App interface for alarm settings and threshold adjustments

Figure 7.1: Alarm Settings in App

7.1 Adjusting Settings on the Device

You can adjust fault settings directly on the device:

Flowchart for adjusting fault settings on the device

Figure 7.2: Fault Settings Adjustment Flow

  1. Long press OK key: To enter the settings states and show the settings.
  2. Canvia la configuració: Use the UP/DOWN keys to adjust values.
  3. Short press OK key: To confirm the settings on the current page and jump to the next settings page.
  4. Long press OK key: To exit the settings states and save the settings.

7.2 Key Protection Functions and Default Settings

8. Manteniment

9. Solució De Problemes

El dispositiu no s'encén:
Check the main power supply and ensure all wiring connections are correct and secure.
Problemes de connexió Wi-Fi:
If the WiFi indicator light is fast flashing, it's searching for a signal. Slow flashing indicates an offline status. Long-press the third key on the meter's screen (the one showing voltage) for three seconds to initiate pairing mode if it doesn't connect automatically. Ensure your router is working and the device is within range.
No leakage value detected:
Ensure one zero wire and three fire wires pass through the current transformer at the same time. Incorrect CT wiring will prevent leakage detection.
Protection tripping unexpectedly:
Review your alarm settings (Over Voltage, sota el voltage, Over Current, etc.) in the app or on the device. Ensure the thresholds are appropriate for your electrical load and system. Check for actual electrical faults in your system.
Lectures inexactes:
Verify that the current transformer is correctly installed and all wiring is secure. Ensure the device is configured for the correct phase system (3-phase).
El dispositiu no respon:
Try restarting the device by cycling its power. If issues persist, consider resetting to factory settings (refer to the settings menu, default OFF).

10. Consells d'usuari

11. Garantia i Suport

For technical support, troubleshooting assistance, or warranty inquiries, please contact your retailer or the manufacturer directly. Please retain your purchase receipt as proof of purchase for any warranty claims.

Documents relacionats - EAEMP3C-100-TY-W

Preview EARU EAMPManual d'usuari del protector d'energia intel·ligent WiFi de la sèrie DW-TY-63 | Vol.tage, Corrent, Protecció contra fuites
Manual d'usuari complet per a l'EARU EAMPProtector d'energia intel·ligent WiFi sèrie DW-TY-63. Més informació sobre la instal·lació, les característiques, les especificacions tècniques, el control de l'aplicació i la resolució de problemes per a vol.tagprotecció contra e, corrent i fuites.
Preview Earu EAMPManual d'usuari del protector d'energia intel·ligent WiFi de la sèrie DW-TY-63
Manual d'usuari i especificacions tècniques de l'Earu EAMPProtector d'energia intel·ligent WiFi sèrie DW-TY-63, que detalla la instal·lació, la connexió de l'aplicació, la configuració dels paràmetres i les funcions de seguretat.
Preview EARU EAPDX-40/63 Series Adjustable VoltagManual d'usuari del protector de corrent i electròniques
User manual for the EARU EAPDX-40/63 Series Adjustable Voltage & Current Protector, detailing specifications, features, and operation for electrical protection. Includes setup instructions and parameter configuration.
Preview PC321-Z-TY Cl d'alimentació monofàsica/trifàsicaamp Guia d'inici ràpid
Get started with the EARU PC321-Z-TY Smart Power Clamp. This guide covers installation, configuration, and features for monitoring single/3-phase electricity usage with ZigBee connectivity and the Smart Life app.
Preview EARU EAMPManual d'usuari del protector d'energia intel·ligent WiFi de la sèrie DW-TY-63
Manual d'usuari complet per a l'EARU EAMPDW-TY-63 series WiFi Smart Energy Protector, detailing features, installation, app connection, parameter settings, and troubleshooting. Covers over/under voltage, over current, leakage protection, energy monitoring, and remote control.
Preview EARU D52-2066 Series Single Phase Multi-functional Energy Meter | Technical Specifications
Detailed technical specifications and wiring instructions for the EARU D52-2066 Series DIN-rail single-phase multi-functional energy meter, measuring AC voltage, current, active power, power factor, frequency, and electric energy.