1. Introducció
The EZ9901 Digital PH/TDS/TEMP Meter is a versatile 3-in-1 handheld device designed for accurate measurement of Potential Hydrogen (pH), Total Dissolved Solids (TDS), Electrical Conductivity (EC), and Temperature in various water sources. This high-accuracy tester is ideal for monitoring drinking water, aquariums, swimming pools, agricultural water, and natural water bodies.

2. Contingut del paquet
Si us plau, comproveu el paquet per veure si hi ha els elements següents:
- 1 x EZ9901 Digital PH/TDS/TEMP Meter
- 2 x Calibration packets (4.00 + 6.86 pH Buffer Powder)
- 1 x Manual d'usuari (aquest document)
3. Característiques del producte
- Measures pH, EC, TDS, and Temperature simultaneously.
- Pantalla digital per a lectures clares.
- 1, 2, or 3-point automatic pH calibration.
- Compensació automàtica de temperatura (ATC) de 0 a 60 °C.
- Replaceable electrode for extended device lifespan.
- Automatic power-off function after 5 minutes of inactivity.
- Data-hold function to freeze readings.
- Low battery indicator for timely battery replacement.
- High accuracy for reliable measurements.
4. Diagrama de peces
Familiarize yourself with the components of your EZ9901 meter:

- Caixa de la bateria: Houses the batteries.
- pH/TDS Display: Shows measurement readings.
- Botó ON/OFF: Encén o apaga el dispositiu.
- TEMP/CAL Button: Used for temperature unit switching and calibration.
- Botó MODE: Switches between pH and TDS measurement modes.
- Protection Cap: Covers and protects the electrode.
5. Configuració i funcionament
5.1 Encès/Apagat
Premeu el botó ON/OFF botó per encendre o apagar el mesurador.
5.2 Mode Switching (pH / TDS)
To switch between pH and TDS measurement modes:
- Enceneu el mesurador prement ON/OFF.
- The display will show the last used mode (e.g., TEMP).
- Premeu el botó MODE button to cycle through pH and TDS modes.

5.3 Temperature Unit Switching (°C / °F)
To switch between Celsius (°C) and Fahrenheit (°F) temperature units:
- Enceneu el mesurador prement ON/OFF.
- The display will show the current temperature unit.
- Premeu el botó TEMP/CAL button to toggle between °C and °F.
5.4 TDS Calibration
The instrument is factory calibrated for TDS. If recalibration is necessary, use a 1413µs/cm standard solution.

- Prepare 250ml of 1413µs/cm standard solution.
- Enceneu el comptador.
- Premeu el botó MODE button to enter TDS mode.
- Manteniu premut el botó TEMP/CAL button for 5 seconds. The display will flash '706' three times.
- The TDS calibration is finished.
5.5 Calibració de pH
The meter supports 1, 2, or 3-point pH calibration using standard buffer solutions (6.86, 4.00, 9.18 pH).

- For 6.86 pH point:
- Prepare 250ml of 6.86 pH standard solution.
- Enceneu el comptador.
- Premeu el botó MODE button to enter pH mode.
- Manteniu premut el botó TEMP/CAL button for 5 seconds. The display will flash '6.86' three times.
- The 6.86 pH calibration is finished.
- For 4.00 pH point (after 6.86 pH calibration):
- Prepare 250ml of 4.00 pH standard solution.
- Ensure 6.86 pH calibration is complete.
- Premeu breument TEMP/CAL button again. The display will flash '4.00' three times.
- The 4.00 pH calibration is finished.
- For 9.18 pH point (after 6.86 pH calibration):
- Prepare 250ml of 9.18 pH standard solution.
- Ensure 6.86 pH calibration is complete.
- Premeu breument TEMP/CAL button again. The display will flash '9.18' three times.
- The 9.18 pH calibration is finished.
Nota: If you calibrate the meter in the wrong solution or in the air, it will flash "ERR" on the screen. The meter will return to the last step of operation. If necessary, recalibrate the meter.
6. Manteniment
6.1 Substitució de la bateria
When the low battery indicator flashes, it's time to replace the batteries.
- Obriu la caixa de la bateria.
- Traieu les piles velles.
- Replace with new 3*1.5V (AG-13 button cell) batteries, ensuring correct polarity.
- Tanqueu la caixa de la bateria.
6.2 Substitució d'elèctrodes
If the electrode is damaged or no longer provides accurate readings after cleaning and calibration, it may need replacement.
- Turn the protection cap left to remove it.
- Pull out the old electrode horizontally.
- Insert the new electrode.
- Substituïu la tapa de protecció.
6.3 Atenció general
- Always replace the protection cap after use to prevent damage to the electrode.
- Clean the electrode with distilled water after each use.
- Guardeu el mesurador en un lloc fresc i sec.
7. Especificacions
Detailed specifications for the EZ9901 Digital PH/TDS/TEMP Meter:

| Paràmetre | EZ9901 |
|---|---|
| Interval | pH: 0.00 - 14.00pH TDS: 1 - 19999ppm TEMP: 0 - 60.0°C / 32.0 - 140.0°F |
| Resolució | pH: 0.01pH TDS: 1ppm |
| Precisió (@25°C/77°F) | pH: ±0.05pH TEMP: ±0.5°C TDS: ±2% |
| Calibració | pH: 6.86 point: Accuracy ±0.1pH; 6.86/4.00 (6.86/9.18) points: Accuracy ±0.05pH; 6.86/4.00/9.18 points: Accuracy ±0.02pH TDS: Calibrated by factory (1413µs/cm) |
| Compensació temporal | Automatic temperature compensation (0-60°C) |
| Battery/Auto power-off | 3*1.5V (AG-13 button cell) Auto power-off: 5 Minutes Low power protection system / battery indicator |
| Medi ambient | 0 to 60.0°C (32.0 - 140.0°F); RH 100% |
| Dimensions/Pes | 183*37*37mm (7.2*1.5*1.5in) / 90g (3.2oz) |

8. Solució De Problemes
- "ERR" Message During Calibration: If the display shows "ERR" during calibration, it indicates that the meter was calibrated in the wrong solution or in the air. Please ensure the correct buffer solution is used and the electrode is fully immersed. Recalibrate the meter following the steps in Section 5.4 and 5.5.
- Lectures inexactes:
- Ensure the electrode is clean. Rinse with distilled water.
- Comproveu el nivell de la bateria; substituïu-la si és baixa.
- Recalibrate the meter if it hasn't been calibrated recently or if readings are consistently off.
- Ensure the temperature of the sample is within the meter's operating range.
- Sense problemes de pantalla/alimentació:
- Comproveu si les piles estan inserides correctament.
- Canvieu les piles si són velles o esgotades.
9. Consells d'usuari
- For best accuracy, always ensure the electrode is thoroughly rinsed with distilled water before and after each measurement.
- When measuring, gently stir the meter in the sample to ensure a stable reading.
- Keep calibration solutions fresh and at room temperature for optimal calibration results.
- Avoid touching the electrode with your fingers, as oils and contaminants can affect readings.
10. Garantia i Suport
For warranty information, technical support, or service inquiries, please contact your original seller or refer to the product's purchase documentation. Keep your proof of purchase for any warranty claims.
11. Vídeo del producte
Mireu aquest vídeo per obtenir una visió generalview of the EZ9901 Digital PH/TDS/TEMP Meter.