CEM DT-5301

CEM DT-5301 Circuit Resistance Tester

Manual d’instruccions de l’usuari

Model: DT-5301

1. Introducció

The CEM DT-5301 is a high-precision digital instrument designed for measuring loop resistance and prospective short circuit (PSC) current. It also features capabilities for AC/DC voltage and resistance measurements. This tester is equipped with a large LCD with backlight for clear readings and a dual injection molded case for enhanced user safety and durability. It is an essential tool for electricians and technicians working with electrical installations.

CEM DT-5301 Circuit Resistance Tester and its carrying case
Figure 1: CEM DT-5301 Circuit Resistance Tester and its carrying case.

2. Contingut del paquet

Si us plau, comproveu el contingut del paquet per assegurar-vos que tots els articles hi són i no estan danyats:

  • CEM DT-5301 Circuit Resistance Tester
  • Test Leads (Red, Green, Black)
  • Cable d'alimentació
  • Maleta de transport
  • Manual d'instruccions (aquest document)
CEM DT-5301 Circuit Resistance Tester with included test leads and power cord
Figure 2: DT-5301 tester with included accessories.

3. Setup and Safety Precautions

3.1 Instal·lació de la bateria

The DT-5301 requires batteries for operation (not included). Refer to the battery compartment on the back of the device for proper installation. Ensure correct polarity.

3.2 Inspecció inicial

Before each use, inspect the tester and test leads for any signs of damage, cracks, or exposed wiring. Do not use the device if it appears damaged.

3.3 Directrius de seguretat

  • Always ensure the device is set to the correct function and range before connecting to a circuit.
  • No supereu les classificacions màximes d'entrada per a cap funció.
  • Wear appropriate personal protective equipment (PPE) when working with electrical circuits.
  • The device is rated CAT III 600V. Do not use it on circuits exceeding this rating.
  • Ensure proper grounding when performing tests.

4. Instruccions de funcionament

4.1 Dispositiu acabatview

Davant view of the DT-5301 tester highlighting its wide measurement range down to 0.01Ω loop resistance
Figure 3: Front panel of the DT-5301 with measurement range indication.

The DT-5301 features a large LCD display, a rotary dial for function selection, and a 'TEST' button. It also includes a backlight button for visibility in low-light conditions.

4.2 Wiring Connection Check

The device is equipped with three LEDs to indicate the status of line connections (P-E, P-N). When P-E and P-N indicator lights are on, the line is connected correctly. If the P≥N indicator light is on, the line is connected incorrectly, and you should not proceed with measurements.

Close-up of the DT-5301 display showing P-E and P-N indicator lights for checking wiring connection status
Figure 4: LED indicators for wiring connection status.

4.3 Realització d'una prova

  1. Connect the test leads to the appropriate terminals on the DT-5301 and to the circuit under test.
  2. Select the desired function (Loop Tester or PSC Tester) and range using the rotary dial. Available ranges include 20Ω, 200Ω, 2000Ω for Loop Impedance and 200A, 2000A, 20KA for PSC.
  3. Ensure the wiring connection is correct by observing the P-E and P-N indicator lights.
  4. Press the 'TEST' button to initiate the measurement. The tester will display the result for 5 seconds, then revert to displaying the voltage.

4.4 Funció de retroiluminació

Press the light bulb button to activate the display backlight for improved visibility in dimly lit environments.

5. Manteniment

5.1 Neteja

Wipe the device with a dry, soft cloth. Do not use abrasive cleaners or solvents. Ensure the device is powered off and disconnected from any circuits before cleaning.

5.2 Substitució de la bateria

When the low battery indicator flag is displayed on the LCD, replace the batteries immediately to ensure accurate measurements. Refer to the battery compartment for instructions on how to open and replace the batteries.

5.3 Emmagatzematge

Store the DT-5301 in a cool, dry place, away from direct sunlight and extreme temperatures. The recommended storage temperature is -10°C to 60°C (14°F to 140°F) with humidity below 70% RH. If storing for extended periods, remove the batteries to prevent leakage.

6. Solució De Problemes

  • "Temperature is High" Warning: If the LCD displays "Temperature is High" and flashes, the internal resistance is overheating. The tester will automatically cut off and lock. Allow the device to cool down before attempting further measurements.
  • "250V" Warning: If the LCD flashes "250V", it indicates an overload protection trigger due to the voltage of P-E reaching 250V. The tester will stop the test to protect the device. Disconnect immediately and check the circuit voltage.
  • Incorrect Wiring Indication (P≥N light): If the P≥N indicator light is on, the wiring connection is incorrect. Recheck your connections to ensure they are properly established (P-E and P-N lights should be on for correct wiring).
  • Indicador de bateria baixa: If the low battery flag is displayed, replace the batteries as described in the Maintenance section.
  • Cap pantalla/Dispositiu que no s'encén: Comproveu la instal·lació de les piles i assegureu-vos que les piles siguin noves.
DT-5301 display showing an 'Overheating Alert' and automatic locking feature
Figure 5: Overheating alert on the DT-5301 display.

7. Especificacions

The following table details the technical specifications of the CEM DT-5301 Circuit Resistance Tester:

Table detailing the technical specifications of the DT-5301, including functions, max resolution, and accuracy
Figure 6: Technical Specifications of the DT-5301.
Funció Resolució màxima Precisió
Impedància de bucle 20/200/2000Ω ±2.5% rdg ±4dgts
AC Test Current 20Ω 25A; 200Ω 2.3A; 2000Ω 15mA ±2% rdg ±5dgts
AC Test Period 20Ω 20ms; 200Ω 40ms; 2000Ω 280ms ±2% rdg ±5dgts
PSC 200A (2.3A 40ms); 2000A (25A 20ms); 20KA (25A 20ms) Consider accuracy impedance
Voltage 50V ~ 250V ±2% rdg ±5dgts
Resistència 0.1 kΩ ±1.0% rdg ±2dgts

Especificacions generals:

  • Vol. Operatiutage: 230V +10% -15% (195V ~ 253V) 50Hz
  • Estàndard de seguretat: IEC61010-1 CATIII 600V
  • Temperatura de funcionament: De 0 °C a 40 °C (32 °F a 104 °F) i humitat per sota del 80% d'HR
  • Temperatura d'emmagatzematge: -10 °C a 60 °C (14 °F a 140 °F) i humitat per sota del 70% RH
  • Característiques: Large LCD with backlight, 3 LEDs for wiring indication, Dual injection molded case, Wide measuring range (down to 0.01Ω loop resistance), Automatic lockout on overheat.

8. Consells d'usuari

  • Always double-check your connections before pressing the 'TEST' button to avoid incorrect readings or potential damage.
  • Utilize the backlight feature in poorly lit areas for better readability of the display.
  • For critical measurements, consider performing the test multiple times to ensure consistency and accuracy.
  • Keep the test leads organized and free from tangles to prevent damage and ensure safety.

9. Garantia i Suport

Per obtenir informació sobre la garantia, assistència tècnica o consultes sobre el servei tècnic, consulteu la documentació que s'inclou amb la compra o poseu-vos en contacte amb el vostre distribuïdor. Conserveu el comprovant de compra per a reclamacions de garantia.

Documents relacionats - DT-5301

Preview CEM DT-5301 Digital Loop/PSC Tester: Specifications and Features
Detailed specifications, features, and electrical characteristics of the CEM DT-5301 Digital Loop and Prospective Short Circuit Current (PSC) Tester. Includes general specifications, loop resistance, prospective short current, and AC voltage mesures.
Preview Provador d'instal·lacions multifunció CEM DT-6650: especificacions tècniques i característiques
Informació detallada sobre el provador d'instal·lacions multifunció CEM DT-6650, incloent-hi les seves característiques, especificacions tècniques, informació de seguretat i accessoris. Aquest provador està dissenyat per a proves de seguretat d'instal·lacions elèctriques en aplicacions domèstiques, comercials i industrials.
Preview Manual d'usuari del mesurador de gruix de recobriment CEM Pro DT-156H
Manual d'usuari complet per al CEM Coating Thickness Gauge Pro (DT-156H). Inclou informació general, característiques, especificacions, funcionament, calibratge, configuració, resolució de problemes i més.
Preview Instruccions d'ús per a CEM AC TRMS Clamp Mesurador DT-350H
Instruccions d'ús detallades i especificacions per al CEM AC TRMS Clamp Mesurador, model DT-350H. Inclou precaucions de seguretat, descripció del mesurador, especificacions i procediments de mesura.
Preview Manual d'usuari del termoanemòmetre CEM DT-90: mesura de la velocitat de l'aire i la temperatura
Manual d'usuari detallat per al termoanemòmetre CEM DT-90. Aprèn sobre les seves característiques, especificacions, funcionament i manteniment per a mesures precises de la velocitat de l'aire i la temperatura.
Preview Manual d'usuari del mesurador d'humitat sense agulla CEM DT-128M
Manual d'usuari del mesurador d'humitat sense agulla CEM DT-128M, un mesurador electrònic dampIndicador de humitat per a la detecció no destructiva d'humitat en materials de construcció. Les característiques inclouen lectures ràpides, penetració en profunditat, retenció de dades, visualització MÀX/MÍN, funcions d'alarma i retroiluminació.