Kinco GL100 GL100E

Kinco GL100 / GL100E 10-inch Human Machine Interface User Manual

Models: GL100, GL100E

Marca: Kinco

1. Introducció

This manual provides essential information for the installation, operation, and maintenance of the Kinco GL100 and GL100E 10-inch Human Machine Interface (HMI). The Kinco HMI is designed for industrial control applications, offering a user-friendly interface for monitoring and controlling various processes.

The GL100 and GL100E models are part of the Kinco Green Series, known for their robust design and cost-effectiveness. Key features include a non-hollow mask for enhanced protection against oil pollution and an ultra-thin body design.

Note on Models:

  • GL100: This model does not include an Ethernet interface. It is a direct replacement for the discontinued MT4532T model, sharing the same installation hole size.
  • GL100E: This model features a 10/100M adaptable Ethernet interface. It is a direct replacement for the discontinued MT4532TE model, sharing the same installation hole size.

2. Configuració

2.1 Sobrepassament físicview

The Kinco GL100/GL100E HMI features a 10-inch display and various communication ports on its rear panel.

posterior view of Kinco GL100E HMI showing DC24V, COM0/COM2, USB Slave, USB Host, and Ethernet ports.
posterior view of Kinco GL100E HMI, highlighting the various connection ports.
posterior view of Kinco GL100 HMI showing DC24V, COM0/COM2, USB Slave, and USB Host ports.
posterior view of Kinco GL100 HMI, showing connection ports (without Ethernet).

2.2 Mechanical Dimensions and Cutout Size

Ensure proper space and cutout dimensions for installation. The overall dimensions and required cutout size are critical for secure mounting.

Mechanical dimensions and cutout size diagram for Kinco GL100 and GL100E HMIs.
Mechanical dimensions (Unit: mm) and cutout size for GL100/GL100E.

2.3 Cablejat i connexions

The HMI requires a DC24V power supply. Connect the power, ground (GND), and functional ground (FG) terminals as indicated on the rear panel. The HMI supports various communication interfaces:

  • DC24V GND FG: Power input terminals.
  • COM0/COM2: 9-pin D-SUB connector for serial communication.
  • ESCLAV USB: For connecting to a PC for program download.
  • HOST USB: For connecting USB devices (e.g., USB flash drives).
  • Ethernet (GL100E only): 10/100M adaptable Ethernet interface for network communication.

COM0/COM2 Pin Assignment:

Pin assignment table for COM0/COM2 ports on Kinco GL/GL100/GL100E HMIs.
Pin assignment of the 9-pin male, D-SUB, COM0/COM2 connector.

Nota: COM0/COM2 supports RS232/485/422 communication functions. COM2 specifically supports RS232 communication function.

3. Instruccions de funcionament

3.1 Interfície d'usuari

The Kinco HMI features a touchscreen display for intuitive interaction. The interface allows users to monitor processes, input data, and control connected equipment.

Kinco HMI touchscreen interface with a hand interacting.
Interacting with the Kinco HMI touchscreen.

3.2 Suport lingüístic

The HMI supports multiple languages, including English, Deutsch, Turkish, Chinese, and Korean.

3.3 Software and Programming

The Kinco HMI uses Kinco DTools V3.3 and above for configuration and programming. Programming of MT4000 can be used for Green series HMI after edited by DTools.

For related file downloads, including software and manuals, please visit the official Kinco weblloc: http://en.kinco.cn/download/download.html

4. Manteniment

4.1 Condicions ambientals

To ensure optimal performance and longevity, operate the HMI within the specified environmental conditions:

  • Temperatura ambient de funcionament: 0 °C a 50 °C
  • Humitat ambiental de funcionament: 10% a 90% sense condensació
  • Temperatura ambient d'emmagatzematge: -20 °C a 60 °C
  • Humitat ambiental d'emmagatzematge: 10% a 90% sense condensació
  • Vibració: 10~500Hz, 30m/s², X, Y, Z direction/hour
  • Mode de refrigeració: Refrigeració natural per aire

4.2 Neteja

The HMI features a non-hollow mask, which is effective against oil pollution. For cleaning, use a soft, damp drap. Eviteu productes de neteja abrasius o dissolvents que puguin danyar la pantalla o laasing.

5. Solució De Problemes

5.1 PLC Communication Issues

Kinco HMI supports standard universal protocols such as Codesys, Omron Tag Protocol, CANopen, and Modbus. This allows communication with over 300 PLC manufacturers, including Siemens, Mitsubishi, Keyence, AB, and Delta.

However, communication connection methods may vary between different PLC manufacturers and Kinco HMI. If you encounter communication problems, it is recommended to:

  1. Download the free Kinco software.
  2. Within the software, select your specific HMI model and then choose the PLC family you intend to connect with to verify compatibility and connection settings.

5.2 Discontinued Products

Please note that some older models, such as MT4532T and MT4532TE, have been discontinued. The GL100 and GL100E models serve as direct replacements with the same installation hole sizes.

Table listing alternative and discontinued Kinco HMI products.
Description of alternative and discontinued products.

6. Especificacions

The following table details the technical specifications for the Kinco GL100 and GL100E Human Machine Interfaces:

Detailed specifications table for Kinco GL100 and GL100E HMIs.
Kinco GL100 and GL100E Technical Specifications.
Kinco GL100 / GL100E Specifications
CategoriaParàmetreGL100GL100E
Especificacions de rendimentMida de la pantallaPantalla TFT de 10.1 polzades
Zona d'exhibició222.72 mm (ample) * 125.28 mm (altura)
Resolució1024 * 600 píxels
Color de la pantalla16.7M true color
Display angle of view70/70/60/70 (esquerra/dreta/amunt/avall)
Relació de contrast500:1
Llum de fonsLED
Brillantor460 cd/m²
Vida de contrallumMés de 30000 hores
Panell tàctil4 line precision resistance network (surface hardness 4H)
CPUARM RISC 328K 800MHz
Emmagatzematge128MB NAND Flash Memory + 128MB DDR3 Memory
RTCIntegrat
Extensible memory1 Amfitrió USB
Print portUSB Host/Serial port
EthernetCap10/100M self-adaption
Descàrrega del programaUSB Slave (Micro USB)/U diskUSB Slave (Micro USB)/U disk/Ethernet
Port de comunicacióCOM0:RS232/RS485/RS422
COM2:RS232
Especificacions elèctriquesFont d'alimentació d'entradaDC10V ~ DC28V
Potència nominal6 W @ 24 V CC
Allowable loss of power<3 ms
Resistència d'aïllamentOver 50MΩ@500V DC
Prova d'hi-pot500 VAC 1 minute
Especificacions de l'estructuraPCBNone of spraying
Material de closcaPlàstic d'enginyeria
Mida de la forma280*193*36 mm
Mida de retallada261*180 mm
Pes0.9 kg
Especificacions ambientalsTemperatura ambient de funcionament0 °C ~ 50 °C
Humitat ambiental de funcionament10% a 90% sense condensació
Temperatura ambient d'emmagatzematge-20 °C ~ 60 °C
Humitat ambiental d'emmagatzematge10% a 90% sense condensació
Sine vibration test10~500Hz, 30m/s², X, Y, Z direction/hour
Mode de refrigeracióRefrigeració natural per aire
Certificació del productePanel protection gradeConforming to IP65 certification (4208-93)
CE authenticationEN61000-6-4:2007+A1:2011, EN61000-6-2:2005
ProgramariProgramari de configuracióKinco DTools V3.3 and above

7. Consells d'usuari

  • When connecting to a PLC, always refer to the Kinco software for specific communication settings and protocols to ensure proper integration.
  • For models without Ethernet (GL100), use the USB Slave port for program downloads from your PC.
  • The non-hollow mask design helps protect against oil, making it suitable for environments where oil pollution is a concern.

8. Garantia i Suport

For technical support, software downloads, and additional documentation, please visit the official Kinco weblloc: http://en.kinco.cn/download/download.html

For product inquiries or assistance, you may also contact the seller, Hengnais (Guangzhou) Trading Co., Ltd. They specialize in automation products and are designated agents for Kinco.

All products are guaranteed to be brand new. For any questions, please allow up to 24 hours for a response.

Documents relacionats - GL100 GL100E

Preview Instruccions d'instal·lació de la HMI Kinco MT070/MT070E
Aquest document proporciona instruccions d'instal·lació per als dispositius HMI Kinco MT070 i MT070E, que cobreixen els requisits ambientals, les especificacions d'alimentació, les interfícies externes i la informació del servei postvenda.
Preview Instruccions d'instal·lació de la HMI Kinco MT100/MT100E
Aquest document proporciona instruccions d'instal·lació per a la HMI Kinco MT100/MT100E, que cobreixen els requisits ambientals, les especificacions d'alimentació, les interfícies externes i la informació del servei postvenda.
Preview Instruccions d'instal·lació de la HMI Kinco GL043/GL043E
Guia d'instal·lació completa per als dispositius d'interfície home-màquina (HMI) Kinco GL043 i GL043E, que cobreix els requisits ambientals i d'alimentació, les interfícies externes i els procediments de muntatge.
Preview Guia d'instal·lació de l'HMI Kinco GH043/GH043E
Aquest document proporciona instruccions d'instal·lació i especificacions tècniques per a les unitats d'interfície home-màquina (HMI) Kinco GH043 i GH043E, que cobreixen els requisits ambientals, les especificacions d'alimentació, els procediments d'instal·lació i els detalls de la interfície externa.
Preview Instruccions d'instal·lació de la HMI Kinco GT070E/GT070E-4G/GT070E-WiFi
Guia d'instal·lació per als dispositius d'interfície home-màquina (HMI) Kinco GT070E, GT070E-4G i GT070E-WiFi, que cobreix els requisits ambientals, l'alimentació i les interfícies externes.
Preview Kinco FD Series Servo User Manual - Installation, Operation, and Troubleshooting
Comprehensive user manual for Kinco FD Series Servo Drivers and Motors. Covers product details, installation, configuration, operation modes (Pulse, Speed, Torque, Homing), software (KincoServo), communication (RS232, RS485, CANopen), parameter settings, performance tuning, alarms, and troubleshooting for industrial automation.