VALUE VRR12L/VRR12L-OS

Value Portable Mini Refrigerant Recovery Machine

Models: VRR12L / VRR12L-OS

Introducció

This manual provides essential information for the safe and efficient operation, setup, and maintenance of your Value Portable Mini Refrigerant Recovery Machine (models VRR12L and VRR12L-OS). This unit is designed for the rapid recovery of various refrigerants, featuring a compact design and stable performance. Please read this manual thoroughly before operating the machine.

Davant view of the Value VRR12L refrigerant recovery machine

Figure 1: Value VRR12L Refrigerant Recovery Machine

Especificacions

The following table details the technical specifications for the VRR12L and VRR12L-OS models:

Table of specifications for VRR12L and VRR12L-OS models

Figure 2: VRR12L/VRR12L-OS Specifications Overview

CaracterísticaVRR12LVRR12L-OS
Refrigerants (Category III)R12, R401C, R134a, R500
Refrigerants (Category IV)R22, R401A, R401B, R402B, R407C, R407D, R408A, R409A, R411A, R411B, R412A, R502, R509
Refrigerants (Category V)R402A, R404A, R407A, R407B, R410A, R507
Font d'alimentació220V-240V~50-60HZ115V~/60HZ
Moto Speed1450rpm / 1750rpm1750 rpm
Consum de corrent màxim4A (220-240V) / 8A (115V)4A (220-240V) / 8A (115V)
Motor3/4 CV
CompressorOil-less, Air-cooled, Piston type
Apagat automàtic de seguretat38.5bar / 3850kPa (558psi)
Recovery Rate (Vapor)0.20 kg/min (Cat III), 0.25 kg/min (Cat IV), 0.25 kg/min (Cat V)0.20 kg/min (Cat III), 0.25 kg/min (Cat IV), 0.25 kg/min (Cat V)
Recovery Rate (Liquid)1.60 kg/min (Cat III), 1.80 kg/min (Cat IV), 2.20 kg/min (Cat V)1.60 kg/min (Cat III), 1.80 kg/min (Cat IV), 2.20 kg/min (Cat V)
Recovery Rate (Push/Pull)4.60 kg/min (Cat III), 5.60 kg/min (Cat IV), 5.60 kg/min (Cat V)4.60 kg/min (Cat III), 5.60 kg/min (Cat IV), 6.30 kg/min (Cat V)
Temperatura de funcionament0 ℃ - 40 ℃
Mida (L*W*H)450 * 250 * 355 mm
Pes13.0 kg14.2 kg
TipusHand Tool Parts, Refrigerant recovery machine
OrigenXina continental
CondicióNou
Indústries aplicablesÚs domèstic
Informe de prova de maquinàriaProporcionat
Components bàsicsBomba
CertificacióCE

Components acabatsview

Familiarize yourself with the main components of the refrigerant recovery machine:

Detallada views of the VRR12L unit's front panel, side fan, and connections

Figura 3: Detallada views of the unit's control panel, cooling fan, and connection ports.

  • Interruptor d'alimentació: Control d'encesa/apagada de la unitat.
  • Protector de sobrecàrrega: A safety device that pops out if the current draw exceeds limits.
  • High and Low Pressure Dual Dials: Gauges indicating system pressures.
  • Botó d'ajust: Selects operating modes (Start, Liquid Recovery, Self-cleaning, Gas Recovery).
  • Port d'entrada: For connecting the refrigerant source.
  • Port de sortida: For connecting to the recovery tank.
  • Ventilador de refrigeració: Located on the side, ensures stable operation of the intelligent motor.

Vídeo 1: Acabatview of the VRR12L Refrigerant Recovery Machine and its components.

Configuració

  1. Desembalatge: Carefully remove the recovery machine and any accessories from its packaging. Inspect for any damage.
  2. Col·locació: Place the unit on a stable, level surface in a well-ventilated area, away from direct sunlight or heat sources. Ensure adequate clearance around the cooling fan.
  3. Connexió d'alimentació: Connect the power cord to the unit and then to a suitable electrical outlet matching the unit's power requirements (220V-240V or 115V, depending on model).
  4. Connexions de mànega:
    • Connect the hose from the system to be recovered to the Port d'entrada of the recovery machine.
    • Connect the hose from the Port de sortida of the recovery machine to the recovery tank.
    • Assegureu-vos que totes les connexions estiguin ajustades per evitar fuites.
  5. Comprovació prèvia al funcionament: Verify that the power switch is in the "Off" position before plugging in.

Instruccions de funcionament

The unit features multiple adjustment modes for efficient refrigerant recovery:

  1. Encès: Flip the power switch to the "On" position.
  2. Seleccioneu el mode: Rotate the adjustment knob to select the desired recovery mode:
    • Start (启动): Initiates the recovery process.
    • Liquid Recovery (液态回收): For recovering refrigerant in liquid phase.
    • Gas Recovery (气态回收): For recovering refrigerant in gas phase.
    • Self-cleaning (自清): For purging residual refrigerant from the unit after use.
  3. Monitor Gauges: Observe the high and low pressure dual dials to monitor the recovery process and system pressures.
  4. Interruptor d'alta pressió: The high-pressure switch is a safety feature. If the pressure exceeds the safe limit (38.5bar/3850kPa/558psi), the unit will automatically shut off.
  5. Protector de sobrecàrrega: If the unit draws excessive current, the overload protector button will pop out. Allow 5 minutes for it to reset before attempting to restart the unit.
  6. Finalització: Once recovery is complete, or the recovery tank is full, turn the power switch to "Off".

Manteniment

Un manteniment regular garanteix la longevitat i el rendiment òptim de la vostra màquina de recuperació:

  • Neteja la malla del filtre: After each use, it is recommended to clean the filter screen to prevent blockages and maintain recovery efficiency.
  • Self-cleaning Mode: Utilize the "Self-cleaning" mode after each recovery operation to purge any remaining refrigerant from the internal components, preventing cross-contamination and extending the unit's lifespan.
  • Neteja exterior: Netegeu l'exterior de la unitat amb un anunciamp tela. No utilitzeu productes químics aggressivs ni netejadors abrasius.
  • Emmagatzematge: Store the unit in a dry, clean environment when not in use.
  • Inspeccioneu les mànegues i les connexions: Periodically check hoses for wear, cracks, or damage. Ensure all connections are secure before and after each use.

Resolució de problemes

ProblemaCausa possibleSolució
La unitat no comença.No power, power switch off, or overload protector tripped.Check power connection. Ensure power switch is ON. If overload protector button is popped out, wait 5 minutes for it to reset, then push it back in.
Low recovery rate.Clogged filter screen, incorrect mode selected, or system pressure too low.Clean the filter screen. Ensure the correct recovery mode (Liquid or Gas) is selected. Check system pressure.
La unitat s'apaga de manera inesperada.High-pressure safety shut-off activated or electrical overload.Check system pressures; ensure recovery tank is not full. If overload protector tripped, wait 5 minutes and reset.
Fuga de refrigerant.Loose hose connections or damaged hoses.Tighten all hose connections. Inspect hoses for damage and replace if necessary.

Consells per a l'usuari

  • Always ensure proper ventilation when operating the recovery machine to prevent accumulation of refrigerant vapors.
  • Use appropriate personal protective equipment (PPE) such as safety glasses and gloves when handling refrigerants.
  • Regularly check the unit's power cord for any signs of damage.
  • For optimal performance, ensure the unit is not exposed to extreme temperatures outside its operating range (0℃ - 40℃).

Garantia i Suport

Please note the following regarding warranty and service for this product:

  • Garantia: Unavailable.
  • After-sales Service Provided: No overseas service provided.
  • Servei després de la garantia: Sense servei.

For any inquiries or support, you may contact the seller directly via:

  • Correu electrònic: 2937038264@qq.com
  • WhatsApp: +8616680517119

Màquina de reciclatge de refrigerants VALUE VRR12L: Recuperació ràpida i funcions avançades

Màquina de reciclatge de refrigerants VALUE VRR12L: Recuperació ràpida i funcions avançades

0:29 • 1280×720 • feature_demo

Documents relacionats - VRR12L

Preview Manual d'usuari de la unitat de recuperació VALUE VRR24M-C
Manual d'usuari de la unitat de recuperació de refrigerant VALUE VRR24M-C, que detalla la seguretat general, el funcionament, les especificacions, les peces, el cablejat i la resolució de problemes.
Preview VALUE VRR12L-R32 / VRR24L-R32 Recovery Unit Manual
This manual provides operating instructions, safety guidelines, and troubleshooting tips for the VALUE VRR12L-R32 and VRR24L-R32 Recovery Units. It covers essential information for safe and efficient refrigerant recovery.
Preview Manual d'usuari i informació tècnica de la bomba de buit accionada per inversor VALUE VRP-15DN
Guia completa per a la bomba de buit accionada per inversor VALUE VRP-15DN, que cobreix les especificacions tècniques, les aplicacions, les precaucions de seguretat, les instruccions d'ús, els procediments de manteniment, la guia de resolució de problemes i una llista de peces. Dissenyada per a sistemes HVACR i refrigerants com l'amoníac, l'R-32 i l'R-1234yf.
Preview Manual d'operació de l'eina d'abancada amb bateria de liti VALUE VET-19Li
Manual d'operació de l'eina de flaix de bateria de liti VALUE VET-19Li, que proporciona pautes de seguretat, especificacions tècniques, instruccions d'operació, procediments de càrrega i resolució de problemes.
Preview VALUE VTE Series Power Tube Expander User Manual - Operation and Specifications
User manual for the VALUE VTE Series Power Tube Expander (models VTE-29D, VTE-42D). Includes instructions on charging, oil changes, lubrication, safety, operation, pressure relief, and technical specifications.
Preview Estació de recuperació VALUE VRDDF per a gasos explosius: especificacions tècniques
Especificacions tècniques detallades i característiques de l'estació de recuperació VALUE VRDDF, dissenyada per a la recuperació segura i eficient de refrigerants inflamables, inclosa la certificació ATEX.