GEYA G2R G2R ATS

GEYA G2R Smart ATS Din Rail Dual Power Automatic Transfer Switch User Manual

Model: G2R G2R ATS

1. Introducció

The GEYA G2R-63 Automatic Transfer Switch (ATS) is a PC class infrequent change-over switch designed for AC systems with AC 50-60Hz and rated current 6A-63A. It features a two-station design, typically used for a common power supply (A) and a backup power supply (B). Its primary function is to automatically switch to the backup power supply when the main power fails, ensuring uninterrupted power to the load. The switching speed is less than 50 milliseconds.

When both power sources A and B are available, the device prioritizes the common power supply (A).

2. Especificacions tècniques

Refer to the table below for detailed technical specifications of the GEYA G2R ATS.

Technical Specifications Table for GEYA G2R ATS

Image: Detailed technical specifications including current ratings, voltage, frequency, and protection ranges.

GEYA G2R ATS Specifications
AtributValor
Corrent nominal de funcionament Ie(A)06A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
Aïllament nominal Voltagi Ui690 V
Resistència d'impuls nominal Voltagi Uimp8kV
Voltagi UeAC220V/AC110V
Freqüència nominal50/60Hz
ClasseClasse PC: es pot encendre i carregar sense generar corrent de curtcircuit
Número de pol2P, 4P
Corrent de curtcircuit nominal Iq5 kA
Dispositiu de protecció contra curtcircuits (fusible)RT16-00-63A
Circuit de controlControl nominal voltage Us AC220V/110V, 50/60Hz. Normal working conditions 85%Us-110%Us
Circuit auxiliarAC220V/110V 50/60Hz Ie=5A
220V Overvoltage/UndervoltagRang de protecció electrònicaUndervoltage: 175V (Recovery: 195V), Overvoltage: 260V (Recovery: 240V ±5V)
110V Overvoltage/UndervoltagRang de protecció electrònicaUndervoltage: 85V (Recovery: 95V), Overvoltage: 145V (Recovery: 130V ±5V)
Vida mecànica≥8000 vegades
Vida elèctrica≥1500 vegades
Categoria d'úsAC-31B
CertificacióCE, CB

Dimensions

Dimensions diagram for GEYA G2R ATS

Image: Detailed dimensions for 2P and 4P models, screw torque, and terminal width.

  • 2P Model Dimensions: 108 mm (longitud) x 50.5 mm (amplada) x 78 mm (alçada)
  • 4P Model Dimensions: 108 mm (longitud) x 82.5 mm (amplada) x 78 mm (alçada)
  • Parell de torsió del cargol: 2.5 Nm
  • Terminal Width: 7.4 mm

3. Informació de seguretat

Always observe the following safety precautions when installing, operating, or maintaining the GEYA G2R ATS:

  • La instal·lació i el manteniment només els ha de dur a terme personal qualificat.
  • Ensure all power sources are disconnected before performing any wiring or maintenance.
  • Verify correct phase sequence for input power supply as indicated in the wiring instructions.
  • No feu servir el dispositiu si sembla que està danyat o que no funciona correctament.
  • Avoid touching live electrical components.
  • Assegureu-vos de connectar a terra correctament d'acord amb els codis elèctrics locals.

4. Producte acabatview

The GEYA G2R ATS is designed for seamless power transfer between a common power supply and a backup power supply. Key features include:

  • Automatic and Manual operation modes.
  • Overvoltage i Undervoltagprotecció.
  • Indicator lights for power status and abnormal conditions.
  • Din Rail mounting for easy installation.

Components i indicadors

Davant view of GEYA G2R ATS with labels for 2P model

Imatge: Frontal view of the 2P model G2R-63II ATS, showing input terminals (I, II, N1 A1, N2 A2), Manual/Auto switch, Load ON indicator, and Load output terminals (LOAD N A).

Davant view of GEYA G2R ATS with labels for 4P model

Imatge: Frontal view of the 4P model G2R-63II ATS, showing input terminals (I, II, N1 A1, B1 C1, Generator, Normal Power), Manual/Auto switch, Load ON indicator, and Load output terminals (LOAD N A B C).

  • (I) N1 A1 / B1 C1: Common Power Supply Input (Live)
  • (II) N2 A2 / B2 C2: Backup Power Supply Input (Live)
  • LOAD N A / B C: Load Output Terminals
  • Interruptor manual/automàtic: Selecciona el mode de funcionament.
  • Indicador de càrrega ON: Green light indicates load is powered.
  • Power Indicator Lights (Red/Green): Indicate status of power sources.
  • Maneta d'operació manual: Per a la commutació manual.
  • Din-Rail Buckle: For mounting on a DIN rail.

5. Instal·lació i cablejat

The GEYA G2R ATS is designed for Din Rail mounting. Ensure the mounting surface is stable and secure.

Instruccions de cablejat

IMPORTANT: All wiring must be performed by a qualified electrician and with all power sources disconnected.

Detailed wiring instructions for GEYA G2R ATS

Image: Detailed wiring diagram showing connections for common power supply, backup power supply, and load, along with indicator light explanations.

Wiring diagram for 2P GEYA G2R ATS with voltage protection values

Image: Wiring diagram for a 2P (single-phase) G2R-63II ATS, illustrating connections for backup and common power supplies to a load, along with voltage configuració de protecció.

Wiring diagram for 4P GEYA G2R ATS

Image: Wiring diagram for a 4P (three-phase) G2R-63II ATS, illustrating connections for backup and common power supplies to a load.

  1. Connecteu el Common Power Supply (I) live wire to terminal N1 A1 (or B1 C1 for 4P) and neutral wire to N2 A2 (or B2 C2 for 4P).
  2. Connecteu el Backup Power Supply (II) live wire to terminal N1 A1 (or B1 C1 for 4P) and neutral wire to N2 A2 (or B2 C2 for 4P).
  3. Connecteu el Sortida de càrrega live wire to terminal LOAD N A (or B C for 4P) and neutral wire to LOAD N A.
  4. Ensure the input power supply is connected in the correct phase sequence.
  5. Secure all connections with a screw torque of 2.5Nm.

Note: The input power supply must be connected in the correct phase sequence.

6. Instruccions de funcionament

The GEYA G2R ATS supports both manual and automatic operation modes.

6.1. Mode manual

In manual mode, you can manually switch between the two power sources using the selector switch.

  1. Ensure both power sources are turned on.
  2. Set the selector switch to "Manual".
  3. Manually toggle the switch to select either power source (I) or (II) to supply power to the load.

Important Note on Manual Operation:

  • Manual operation allows for electrical switching, but the speed of operation by users can vary.
  • Excessive silver alloy loss is possible during manual operation if not performed carefully.
  • The selector switch should only be moved to the manual position after all power has been cut off, typically for inspection and maintenance.

6.2. Automatic Mode

In automatic mode, the ATS will automatically detect power failures and restore power, switching between the main and backup supplies.

  1. Set the selector switch to "Auto".
  2. When the main power supply (I) is disconnected, the product will automatically switch to the backup power supply (II).
  3. When the main power supply (I) is restored, the product will automatically switch back to the main power supply.

Important Note on Automatic Mode:

  • The control circuit is immediately energized when the selector switch is in the electric (Auto) position.
  • The internal switch is designed to handle the changeover. The coil can operate normally within 85%-110% of the rated operating voltage.
  • Vol d'entrada massa baixtage may cause the coil to overheat and burn out.

6.3. Sobrevoltage i Undervoltage Protecció

The G2R ATS includes built-in voltage protection features:

  • If the main power supply voltage cau per sota del undervoltage threshold (e.g., 175V for 220V systems), the ATS will automatically switch to the backup power supply.
  • If the main power supply voltage s'eleva per sobre de l'overvoltage threshold (e.g., 260V for 220V systems), the ATS will automatically switch to the backup power supply.
  • Un cop el voltage returns to normal range (e.g., above 195V for undervoltage recovery, below 240V for overvoltage recovery), the ATS will switch back to the main power supply.

Nota:

When abnormal voltage returns to normal voltage, the indicator light flashes for 15 seconds (with a delay of 15 seconds) and then returns to normal light. The power supply of this circuit will only be considered normal in the chip judgment after 15 seconds. Switch between primary and backup logic again.

6.4. Vídeo de demostració del producte

Video: Demonstration of manual and automatic switching, and overvoltage/undervoltage protection functionality of the GEYA G2R ATS.

7. Manteniment

Regular maintenance helps ensure the longevity and reliable operation of your GEYA G2R ATS.

  • Inspeccioneu periòdicament totes les connexions del cablejat per assegurar-vos que estiguin ben ajustades i sense corrosió.
  • Check the device for any signs of physical damage, overheating, or unusual odors.
  • Mantingueu el dispositiu net i lliure de pols i residus.
  • If the device is in manual mode for an extended period, ensure the selector switch is returned to "Auto" for automatic protection.
  • For any internal inspection or repair, always disconnect all power sources and consult a qualified electrician.

8. Solució De Problemes

If you encounter issues with your GEYA G2R ATS, refer to the following common troubleshooting steps:

ProblemaCausa possibleSolució
Load not receiving power in Auto mode.Both main and backup power supplies are off, or one is outside voltage llindars.Check both power sources. Ensure voltages are within normal operating range. Verify indicator lights.
Indicator light flashing for Common/Backup power supply.Vol anormaltage (per sota o per sobre del voltage) detected on that power supply.Consulteu el voltage of the indicated power supply. The ATS will switch to the other source if available. It will return to normal after 15 seconds if voltage s'estabilitza.
Device not switching automatically.Selector switch is in "Manual" mode.Switch the selector to "Auto" mode.
Device feels hot or smells burnt.Control coil overheating due to low input voltage or internal fault.Immediately disconnect all power. Do not operate. Contact a qualified electrician for inspection and repair.

9. Consells d'usuari

  • Solar Power Integration: Yes, this ATS can be used with solar power systems. Connect your inverter output (from solar panels, MPPT, and batteries) to one of the power inputs (e.g., as the backup power source). Ensure the inverter is a pure sine wave type and has a power output above 2000W for optimal performance.
  • Priorització: Remember that when both power sources are available, the ATS is designed to prioritize the common power supply (Source A).

10. Garantia i Suport

For warranty information, technical support, or service inquiries, please contact GEYA Official Store or your authorized dealer. Keep your purchase receipt for warranty claims.

Documents relacionats - G2R G2R ATS

Preview Commutador de transferència automàtica (ATS) GEYA G2R-63/00 - Especificacions tècniques
Especificacions tècniques detallades i guia d'instal·lació per al commutador de transferència automàtica (ATS) GEYA G2R-63/00, que inclou commutació de classe PC per a fonts d'alimentació duals, condicions de funcionament i procediments de manteniment.
Preview Manual del commutador de transferència automàtica dual de commutació ininterrompuda de mil·lisegons de Zhejiang Geya Electrical
Aquest manual proporciona informació detallada sobre el commutador de transferència automàtica dual de commutació ininterrompuda de mil·lisegons de Zhejiang Geya Electrical Co., Ltd., incloent-hi informació general, paràmetres tècnics, instal·lació, cablejat, manteniment i precaucions de seguretat.
Preview Interruptor miniatura intel·ligent de la sèrie GEYA WiFi: instruccions d'ús
Instruccions d'ús detallades i preguntes freqüents per a l'interruptor miniatura intel·ligent de la sèrie GEYA WiFi (sèrie ZJSB9). Apreneu sobre la instal·lació, la configuració, la resolució de problemes, la seguretat i l'aplicació per a la protecció elèctrica de la llar intel·ligent.
Preview Catàleg d'equips elèctrics GEYA: interruptors, contactors i més
Catàleg complet de productes elèctrics GEYA, incloent-hi interruptors automàtics en miniatura, contactors, interruptors de transferència i altres equips de seguretat, amb especificacions, aplicacions i estàndards de compliment.
Preview GEYA Smart Power Protection Product Catalogue
Comprehensive catalogue of GEYA's over/under voltage and current protectors, automatic transfer switches, and energy metering devices, featuring technical specifications, features, and installation guidance for various models.
Preview GEYA GRV8-01.02 Monitoring Voltage Manual d'instruccions del relé
Instruction manual for the GEYA GRV8-01.02 monitoring voltage relay. This document provides detailed information on applications, function features, technical specifications, panel and function diagrams, wiring, and safety guidelines for protecting electrical equipment and motors from over-voltage i sota-voltage.