1. Introducció
This manual provides detailed instructions for the installation, operation, and maintenance of the DROK AC Power Meter D69-2049. This digital multi-function meter is designed to measure AC voltage, AC current, active power, and electric energy (kWh) with high accuracy. Please read this manual thoroughly before use to ensure correct operation and to prevent damage to the device.
2. Contingut del paquet
En obrir el paquet, comproveu que tots els elements que s'enumeren a continuació hi són presents i que es troben en bon estat:
- 1 x AC 80.0-300.0V 0.01-100A 4-in-1 AC Voltmeter Ammeter Power Energy Meter (Model D69-2049)
- 1 x CT Current Transformer
- 1 x manual d'usuari en anglès
3. Especificacions
| Característica | Valor |
|---|---|
| Precisió | 1% ±2 words |
| Vol. ACtage Rang | AC 80.0-300.0V |
| Interval de corrent de CA | AC 0-99.99A (Minimum resolution 0.01A; displays 100.0A when current exceeds 100A) |
| Active Power Range | 0-45000W (0.1W resolution for < 9999.9W; 1W resolution otherwise) |
| Electric Energy Range | 0-9999999Kwh (0.001kwh for 0-9999.999kwh; 0.01kwh for 10000.00-99999.99kwh; 0.1kwh for 100000.0-999999.9kwh; 1Kwh otherwise) |
| Velocitat de mesura | 2 vegades per segon |
| Color | Negre |
| Pes | 110 g |
| Tipus de visualització | Només digital |
| Origen | Xina continental, Guangdong |
4. Dimensions
The physical dimensions of the meter are as follows:
- Mida externa: 79 mm (llargada) x 43 mm (amplada) x 48 mm (profunditat)
- Dimensió de muntatge: 76 mm (llargada) x 39 mm (amplada)
5. Advertències de seguretat
Failure to follow these warnings may result in damage to the meter or personal injury.
- Connexió incorrecta: The meter will be destroyed if you make an incorrect connection method with the voltage input (green terminal) and the secondary current transformer (blue terminal). Ensure all connections are correct before applying power.
- Compatibilitat amb fonts d'alimentació: This meter is designed to measure 50Hz AC city electricity ONLY. It will be destroyed if used to measure square wave, output of an inverter, or correction sine wave power sources.
6. Configuració i instal·lació
Follow these steps for proper installation of the AC Power Meter D69-2049:
- Muntatge: Install the meter into a panel cutout with dimensions of 76mm x 39mm.
- Voltage Entrada: Connect the AC power source to the green terminal block labeled 'VOLTAGE INPUT' on the meter. Ensure the voltage is within the specified AC 80.0-300.0V range.
- Current Transformer Connection:
- Connect the blue terminal block labeled 'CT SECONDARY' to the secondary wires of the included current transformer.
- Pass the wire of the load you wish to measure through the middle of the current transformer.
- Important: Do not connect the CT secondary directly to the voltage input. Ensure the wire passes through the CT correctly.
Refer to the safety warnings section before making any connections.
7. Instruccions de funcionament
Once properly installed and powered on, the meter will automatically display the measured values for AC voltage, AC current, active power, and accumulated electric energy (kWh) on its color LCD screen.
Auto-Saving Function:
The meter features an auto-saving function for electric energy. When power is off, the accumulated electric energy (kWh) value will be saved. The saved energy will continue to accumulate from the last recorded value when the meter is powered on again.
8. Manteniment
To ensure the longevity and accurate performance of your DROK AC Power Meter D69-2049, follow these simple maintenance guidelines:
- Neteja: Feu servir un drap suau i sec per netejar la pantalla iasing. Do not use abrasive cleaners or solvents, as they may damage the surface.
- Medi ambient: Keep the meter in a dry environment, away from excessive dust, moisture, and direct sunlight.
- Inspecció: Reviseu periòdicament totes les connexions del cablejat per assegurar-vos que estiguin ben fixades i que no presentin corrosió.
9. Solució De Problemes
If you encounter issues with your meter, refer to the following common problems and solutions:
| Problema | Causa possible | Solució |
|---|---|---|
| Meter does not power on or display anything. | Sense poder al voltage input terminals, or incorrect wiring. | Check the power supply to the green voltage input terminals. Verify all wiring connections are secure and correct as per the setup instructions. |
| Incorrect or erratic readings. | Incorrect CT connection, incompatible power source, or faulty wiring. | Ensure the load wire passes correctly through the CT and the CT secondary is connected to the blue terminals. Confirm the power source is 50Hz AC city electricity (not square wave or inverter output). Recheck all wiring for loose connections. |
| Meter damaged after connection. | Wrong connection method (e.g., CT secondary connected to voltage input) or incompatible power source. | Review the safety warnings and setup instructions carefully. Ensure the CT secondary is never connected directly to the voltage input. Only use with 50Hz AC city electricity. |
10. Consells d'usuari
No hi havia consells específics per a l'usuari disponibles del servei de clients.viewo preguntes i respostes per a aquest producte.
11. Garantia i Suport
For any technical assistance, warranty claims, or further inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase for warranty purposes.