1. Introducció
The Habotest HT107 Pro Socket Tester is a professional tool designed for comprehensive electrical socket testing. It helps identify common wiring faults, ensuring the safety of your electrical installations. This manual provides essential information for the safe and effective use of your device.

Figure 1: Habotest HT107 Pro Socket Tester (HT107B, HT107D, HT107E variants)
The tester is available in different plug types: HT107B (US), HT107D (EU), and HT107E (UK).
2. Informació de seguretat
WARNING: Always prioritize safety when working with electricity. Read and understand all instructions before use.
- Check if the instrument's appearance is normal and if the device can be turned on and displays information correctly.
- Regularly inspect the instrument for any damage.
- After using, store the device in a dry and cool environment, free from corrosive gases.
- No utilitzeu el dispositiu si sembla que està danyat o no funciona correctament.
- Ensure household appliances are turned off and power interrupted when performing RCD tests to avoid safety hazards.
3. Contingut del paquet
El paquet normalment inclou:
- 1 x Habotest HT107 Socket Tester (specific model: HT107B, HT107D, or HT107E)
- 1 manual d'usuari (anglès)
- Caixa d’embalatge

Figura 2: Example Package Contents (HT107E model shown)
4. Producte acabatview
The HT107 series socket testers are multifunctional digital display devices designed for quick and accurate detection of socket wiring status. Key features include:
- Plug-and-play one-touch testing.
- Assistance in detecting sockets with safety hazards.
- Three-prong socket wire sequence detection.
- Fase voltage (L-N) detection.
- Vol. de fuitestage (N-E) detection.
- Residual Current Device (RCD) detection.
- Vol en temps realtage testing of live and neutral wires.
- Voltage testing for leakage between neutral wire and ground wire.
- Insulation design for voltage resistance and automatic protection.
- Supports real-time monitoring of voltage when continuously plugged into a socket.

Figure 3: Key Features of the HT107 Socket Tester
4.1. Device Layout and Indicators

Figure 4: HT107 Panel Layout and Indicator Meanings
The device features an LCD display, indicator lights, and a leakage test button. The indicator lights provide a quick visual reference for the socket's wiring status:
| Indicator Lights (Left to Right) | Socket Connection Detection |
|---|---|
| ● ● ○ (Red, Red, Off) | Connexió correcta |
| ● ○ ○ (Red, Off, Off) | Terra oberta |
| ○ ● ○ (Off, Red, Off) | Obriu neutre |
| ○ ● ● (Off, Red, Red) | Live/ground reverse |
| ● ○ ● (Red, Off, Red) | Live/neutral reverse |
| ● ● ● (Red, Red, Red) | Live/ground reverse, missing ground |
Note: '●' indicates the light is ON, '○' indicates the light is OFF.
5. Configuració i funcionament
5.1. Configuració inicial
- Unpack the Habotest HT107 Socket Tester and ensure all components are present and undamaged.
- Familiarize yourself with the device layout, LCD display, indicator lights, and the RCD test button.
- Ensure the socket tester matches the plug type of your region (HT107B for US, HT107D for EU, HT107E for UK).

Figure 5: Plug Specifications for Different Models
5.2. Basic Socket Testing
- Insert the Habotest HT107 Socket Tester firmly into the socket you wish to test.
- Observe the indicator lights and the LCD display. The indicator lights will illuminate in a specific pattern to show the wiring status (refer to Section 4.1, Figure 4).
- The LCD display will show real-time voltage readings (L-N for phase voltage, N-E for leakage voltagi).
Video 1: Demonstration of plugging in the HT107D and HT107E socket testers and observing readings.
5.3. RCD (Residual Current Device) Testing
IMPORTANT: Before performing an RCD test, ensure all household appliances connected to the circuit are turned OFF and verify that the power interruption will not pose any safety hazards. This test will trip the RCD/breaker.
- Insert the tester into a correctly wired three-hole power socket.
- Press the RCD test button (typically held for less than 3 seconds).
- The RCD should trip, cutting power to the socket. This indicates the RCD is functioning correctly.
- If the RCD does not trip, it may be faulty and requires inspection by a qualified electrician.

Figure 6: Performing an RCD Test
5.4. Voltage Detection of Neutral Line and Ground Line
El voltage between the neutral line (N) and the ground line (E) should ideally be "0" or close to zero under normal conditions. If the voltage is too high, it may indicate one of the following issues:
- Excessive power consumption, undersized or overlong wires (resulting in high resistance).
- Loose or poor contact of the neutral line joint, or oxidation.
- Disconnection or severe oxidation of the neutral line, causing the electrical circuit to be incomplete. The voltage drop between the neutral line and the ground line is determined by the load impedance of the electrical appliance.

Figure 7: Neutral-Ground Voltage Detection: Normal vs. Safety Hazard
6. Manteniment
- Mantingueu el dispositiu net i sec. Netegeu-lo amb un drap suau i sec.amp drap si cal. No utilitzeu productes de neteja abrasius ni dissolvents.
- Store the tester in a cool, dry place away from direct sunlight and corrosive materials.
- Eviteu deixar caure o sotmetre el dispositiu a forts impactes.
- Regularly check the plug pins for any signs of wear or damage.
7. Troubleshooting Common Wiring Faults
The HT107 Pro Socket Tester helps identify various wiring issues. Refer to the indicator light patterns (Section 4.1) for diagnosis. Below are common issues and their implications:

Figure 8: Troubleshooting: Lack of Ground Wire and Fire Zero Line Inversely Connected

Figure 9: Troubleshooting: Fire and Ground Wires Connected Reversely and Zero Line Missing
7.1. Common Hidden Risks in Home Electrical Installations

Figure 10: Common Wiring Faults and Their Detection
- Missing Ground Wire/Neutral Wire: The ground wire or neutral wire of the socket is not connected. This is a critical safety measure.
- Misconnection: Live Wire and Ground Wire / Live Wire and Neutral Wire: Incorrect connections during circuit installation can lead to significant safety hazards.
- Phase-Ground Fault and Lack of Ground: The live wire and ground wire are reversed, and there is a lack of ground wire connection.
If any wiring faults are detected, consult a qualified electrician immediately to rectify the issues and ensure electrical safety.
8. Especificacions
| Característica | HT107B (US) | HT107D (EU) | HT107E (UK) |
|---|---|---|---|
| Voltage Rang | CA 90~250V | CA 90~250V | CA 90~250V |
| Prova GFCI | > 5 mA | - | - |
| Prova RCD | - | > 30 mA | > 30 mA |
| Voltage Measurement (48V~250V) | ✓ | ✓ | ✓ |
| Frequency Measurement (45~65Hz) | ✓ | ✓ | ✓ |
| Leakage Voltage Measurement (0V~99V) | ✓ | ✓ | ✓ |
| Pantalla LCD | ✓ | ✓ | ✓ |
| Two Color Backlight | ✓ | ✓ | ✓ |
| Pes del producte | Aprox. 64 g | Aprox. 72 g | Aprox. 75 g |
| Mida del producte (L x W x H) | 68x65x62 mm | 68x65x69 mm | 68x65x64 mm |
| Classificació de seguretat | EN61010-1-2-030, EN61326-1, CAT II 300V | ||

Figura 11: Especificacions detallades del producte
Certificacions: CE, RoHS
Número de model: HT106/107
Origen: Xina continental
9. Consells d'usuari
- For quick checks, simply plug in the tester and observe the indicator lights.
- Always perform the RCD test with caution, ensuring no sensitive equipment is connected to the circuit.
- The LCD display provides more detailed voltage information, which can be useful for diagnosing subtle issues beyond simple wiring faults.
- Consider using this tester for initial circuit acceptance in new installations or during routine inspections in homes, offices, or factories.

Figure 12: Application Scenarios for the Socket Tester
10. Garantia i Suport
For detailed warranty information and technical support, please refer to the official product documentation or contact the manufacturer/seller directly.
Una versió digital del manual d'usuari està disponible per descarregar: Habotest HT107 User Manual (PDF).