ANENG 615

ANENG 615 Smart Digital Multimeter Instruction Manual

Model: 615 | Brand: ANENG

1. Introducció

This manual provides detailed instructions for the safe and effective use of the ANENG 615 Smart Digital Multimeter. This instrument is an automatic range digital multimeter with a 6000-count display, powered by a rechargeable lithium battery, and features true RMS measurement capabilities. Please read this manual thoroughly before operation to ensure proper usage and safety.

2. Informació de seguretat

To prevent electric shock or personal injury, and to avoid damage to the multimeter or the equipment under test, please follow these safety guidelines:

3. Contingut del paquet

The ANENG 615 Smart Digital Multimeter package includes the following items:

Image showing the ANENG 615 Multimeter and its accessories: packing box, storage bag, manual, multimeter, test pen line, and charging cable.
Figure 3.1: Accessories List

4. Característiques del producte

The ANENG 615 Smart Digital Multimeter offers a range of advanced features for electrical testing:

Image showing the ANENG 615 Smart Touch Screen Multimeter with a finger touching the screen, highlighting its induction touch screen feature and VA reverse screen for clear visibility in dark environments.
Figure 4.1: Smart Touch Screen and VA Reverse Screen
Image showing the ANENG 615 Multimeter being charged via a Type-C cable plugged into a power strip, with an inset image of the 3.7V 700mAh lithium battery.
Figure 4.2: Lithium Battery Direct Charging

5. Especificacions

FuncióIntervalResolucióPrecisió
Corrent alterna600 mA-10A0.1mA-10mA± (2.5% + 8d)
Corrent DC600 mA-10A0.1mA-10mA± (2.2% + 8d)
Vol. ACtage600mV-600V0.1mV-1V± (1.5% + 10d)
DC Voltage600mV-600V0.1mV-1V± (1.2% + 10d)
Condensador0nF-60mF1pF-1µF± (10% + 8d)
Resistència0Ω-60MΩ0.1Ω-10KΩ± (1.5% + 10d)
Hz (Frequency)0 Hz-60 MHz0.1Hz-10KHz± (4% + 10d)
Temperatura en temps realModel de bateria de liti3.7 V 700 mAh
NCVMida de la pantalla8.95 cm/3.52 polzades
Zero FireWirePantalla tàctil
DíodeLithium battery direct charging
ZumbadorIl·luminació de llanterna
Pes120 gRetenció de dades
Max count6000 recomptesVA reverse screen
MaterialABSIndicador de baixa potència

Note: The parameters are for reference only, and the actual measurement of the specific equipment shall prevail.

Image showing the ANENG 615 Multimeter's function and range table, detailing AC/DC current, AC/DC voltage, capacitor, resistance, Hz, real-time temperature, NCV, Zero FireWire, Diode, Buzzer, Flashlight lighting, Weight, Max count, Material, Data retention, VA reverse screen, and Low power prompt.
Figure 5.1: Function and Range Specifications

6. Configuració

6.1 Charging the Multimeter

The ANENG 615 Multimeter is equipped with a built-in rechargeable lithium battery. To charge the device:

  1. Locate the Type-C charging port on the side of the multimeter (refer to Figure 6.1).
  2. Connect the provided Type-C charging cable to the multimeter and a suitable USB power source (e.g., wall adapter, computer USB port).
  3. El llum indicador de càrrega s'il·luminarà durant la càrrega.
  4. Un cop estigui completament carregat, desconnecteu el cable de càrrega.
Image showing the side view of the ANENG 615 Multimeter with numbered labels pointing to its components, including the Type-C charging port (10).
Figure 6.1: Multimeter Components and Type-C Charging Port

6.2 Connexió dels cables de prova

To prepare for measurements, connect the test leads:

  1. Insert the red test lead into the "INPUT" positive input jack (9).
  2. Insert the black test lead into the "COM" negative input jack (8).
  3. For current measurements (up to 10A), insert the red test lead into the "10A" positive input jack (7).
  4. Ensure a tight engagement with the multimeter jacks to prevent accidental disconnection.
Image showing the side view of the ANENG 615 Multimeter with numbered labels pointing to its components, including the 10A positive input jack (7), COM Negative input jack (8), and INPUT positive input jack (9).
Figure 6.2: Test Lead Connection Points

6.3 Engegada/apagada

To power on the multimeter, press and hold the power button (3) for 2 seconds. To power off, press and hold the same button for 2 seconds.

Image showing the side view of the ANENG 615 Multimeter with numbered labels pointing to its components, including the power button (3).
Figura 6.3: Ubicació del botó d'engegada

7. Instruccions de funcionament

The ANENG 615 Multimeter operates primarily in auto-range mode, simplifying measurements. Use the Function Switch Key (5) and the Hold button (6) for specific operations.

7.1 General Measurement (Auto Range)

When powered on, the multimeter defaults to auto-range mode, automatically detecting and measuring common electrical parameters like voltage, resistance, and continuity. The display will show "Auto".

Video 7.1: Demonstration of the ANENG 615 Multimeter's auto-range function and flashlight feature.

7.2 Modes de mesura específics

Premeu el botó SEL (Function Switch Key) to cycle through different measurement modes if the auto-range does not select the desired function or for specific tests.

Image showing the ANENG 615 Multimeter's main display and controls, including the SEL button for function switching.
Figure 7.1: Multimeter Display and Controls
Diagram illustrating the correct series connection for AC current measurement using the multimeter, showing red and black test leads connected in series with a resistor and a light bulb circuit. It emphasizes that current must be measured in series.
Figure 7.2: Brief Diagram of AC Current Measurement (Series Connection)
Image showing various measurement functions of the ANENG 615 Multimeter, including AC voltage, DC voltage, diode, capacitance, buzzer, Hz, resistance, DC current, and NCV. It also shows the correct connection for DC current measurement.
Figure 7.3: Multifunctional Measurement Examples

7.3 Funció de retenció de dades

To hold the current measured value on the display, short press the "Hold" button (6). Press it again to release the hold function.

Image showing the side view of the ANENG 615 Multimeter with numbered labels pointing to its components, including the Hold button (6).
Figure 7.4: Hold Button Location

7.4 Funcionament de la llanterna

To turn on the back flashlight, long press the "Hold" button (6). Long press again to turn it off. This is useful for illuminating dark work areas.

Image showing the side view of the ANENG 615 Multimeter with numbered labels pointing to its components, including the Hold button (6) which also controls the flashlight.
Figure 7.5: Flashlight Control (Hold Button)

8. Manteniment

8.1 Atenció general

8.2 Manteniment de la bateria

9. Solució De Problemes

This section addresses common issues you might encounter with your ANENG 615 Multimeter.

10. Garantia i Suport

ANENG is committed to providing high-quality products and customer satisfaction. For any questions or support needs, please refer to the following:

10.1 After-Sales Questions

If you have any questions during the use of the product, please contact ANENG customer service. Our customer service team will provide you with satisfactory solutions in a timely manner.

10.2 Quality Issues

In case of quality problems other than "man-made damage" during the use of this product, replacement services or refunds can be provided. For specific product damage, please contact ANENG customer service to confirm and discuss solutions.

10.3 Replacement or Refund Request

To initiate a replacement or refund request:

  1. Contact customer service to provide feedback on product quality problems, ideally with a video for damage determination.
  2. Negotiate a solution with customer service.
  3. If the product is destroyed (smashed) due to quality problems, this is to avoid secondary damage.
  4. Execute the agreed solution.

10.4 Product Use Questions

This brand product is a technical product and requires a certain degree of electrical knowledge. If you encounter operational problems or do not understand how to use the product, please contact ANENG customer service for assistance.

10.5 Product Has Been Artificially Damaged

This brand is mostly used to detect electrical and other measurement products. It requires a certain degree of electrical knowledge. Pay attention to the use of certain operating procedures, select the correct measurement method, and avoid dangerous events. If the customer uses the product improperly and the use method is not equal, resulting in damage to the product, it will be judged as man-made damage, which is not within the scope of after-sales service of the product. However, you can contact ANENG customer service to receive a certain amount of coupons to deduct the newly purchased ANENG products.

Image detailing ANENG's professional after-sales service, outlining steps for contacting customer service, handling quality issues, replacement/refund requests, product not operating properly, questions about product use, artificially damaged products, and getting a coupon for a positive review.
Figure 10.1: ANENG After-Sales Service Guidelines

ANENG 615 Smart Touch Digital Multimeter Product Feature Demonstration

ANENG 615 Smart Touch Digital Multimeter Product Feature Demonstration

0:38 • 1280×720 • feature_demo

Documents relacionats - 615

Preview Manual d'usuari del mesurador tàctil ANENG 683: característiques, especificacions i guia d'operació
Manual d'usuari complet per al multímetre digital ANENG 683. Cobreix la seguretat, les especificacions i les funcions de mesura (vol.tage, corrent, resistència, etc.), i guia operativa per a proves elèctriques.
Preview Multímetre digital intel·ligent ANENG 616: instruccions d'ús i especificacions
Instruccions d'ús completes i especificacions detallades per al multímetre intel·ligent digital ANENG 616. Apreneu a mesurar el volumtage, corrent, resistència, capacitança, freqüència i temperatura de manera segura i eficaç.
Preview ANENG ST183 Cl digitalamp Manual d'usuari del mesurador: especificacions i instruccions
Manual d'usuari complet per a l'ANENG ST183 Digital Clamp Mesurador, detallant les seves especificacions, precaucions de seguretat, instruccions d'ús per a diverses mesures (vol.tage, corrent, resistència, capacitància, freqüència, NCV), manteniment i resolució de problemes.
Preview ANENG 621A Intelligent Digital Multimeter User Manual
User manual for the ANENG 621A intelligent digital multimeter, detailing its features, technical specifications, operating instructions, and maintenance.
Preview ANENG 622A Intelligent Digital Multimeter User Manual
This user manual provides comprehensive instructions for operating the ANENG 622A Intelligent Digital Multimeter. It covers safety precautions, detailed descriptions of the device and its LCD display, technical specifications for various measurement functions (AC/DC voltage and current, resistance, capacitance, frequency, temperature, diode test, continuity), operating guidelines, and procedures for battery and fuse replacement.
Preview ANENG PN129/PN130 Clamp Meter User Manual - High Precision Multimeter
Comprehensive user manual for the ANENG PN129 and PN130 clamp meters. Features include high precision, U-shaped design, AC/DC voltage and current measurement, resistance testing, and NCV sensing. Get detailed specifications and operating instructions.