1. Introducció
The MYPIN LH86-RR4D is a high-precision digital weighing controller meter designed for various industrial automatic control applications. It offers stable and accurate measurement, fast response, and versatile control functions, making it suitable for quantitative/batching systems, floor scales, weighbridges, cement, food packaging, and chemical batching processes. This instrument can be directly connected to load cells or other force-measuring sensors and provides multiple output options for comprehensive system integration.
2. Informació de seguretat
Please read and understand all safety instructions before installation and operation. Failure to follow these instructions may result in equipment damage, personal injury, or improper operation.
- Assegureu-vos que la font d'alimentació voltage matches the device's specifications (90-260V AC/DC).
- All wiring should be performed by qualified personnel and with the power disconnected.
- Avoid installing the device in environments with excessive vibration, high humidity, extreme temperatures, or corrosive gases.
- Proper grounding is essential to prevent electrical shock and ensure stable operation.
- No obriu el dispositiu casing tret que ho indiqui un tècnic qualificat.
3. Contingut del paquet
Verifiqueu que tots els elements siguin presents i no estiguin danyats en desempaquetar-los:
- 1 x MYPIN LH86-RR4D Digital Weighing Controller Meter
- 2 x Brackets de muntatge
- 1 x Manual d'instruccions en anglès

4. Especificacions
| Característica | Descripció |
|---|---|
| Model | LH86-RR4D |
| Entrada | 1-4 Load Cells (weighing/force measuring sensors) or other signals (0-70mV, 4-20mA, 0-10V) |
| Sortida | 4 Relay Outputs (High/Low/Fast/Slow), up to 6 channels of various control outputs |
| Sortida analògica | Isolated current transmission output 4-20mA or 0-10V (arbitrarily settable range) |
| Precisió | 0.1% (five digits) or 0.05% (six digits), floating decimal setting |
| Font d'alimentació | 90-260V AC / DC |
| Interfície de comunicació | RS485, RS232 |
| External Sensor Power | +12/40mA or 150mA, or two-wire 24V/30mA |
| Dimensions | 96 x 48 x 80 mm |
| Material | ABS + metall |
5. Instal·lació i cablejat
5.1 Muntatge
The LH86-RR4D controller is designed for panel mounting. Use the provided brackets to secure the device into a standard panel cutout. Ensure adequate ventilation around the unit.
5.2 Cablejat
All wiring connections are made via the terminal block located at the rear of the device. Refer to the wiring diagram below for correct connections. Ensure power is disconnected before making any connections.

- Power Supply (90-260V AC/DC): Connect the main power supply to the designated terminals.
- Load Cell Input (1-4 PCS LOADCELL): Connect the load cell excitation and signal wires to the EXC+, EXC-, SIG+, SIG- terminals. The device supports 1 to 4 load cells.
- Comunicació RS485: Connect RS485 A and B lines to the corresponding terminals for serial communication.
- Sortides d'alarma (AL1, AL2): These are relay outputs for high/low/fast/slow control. Connect external devices as required.
- RST/TARE: Terminal for external reset or tare functions.
- External Sensor Power: If using isolated sensors requiring external power, connect to the +12/40mA, 150mA, or two-wire 24V/30mA outputs as appropriate.
6. Funcionament
6.1 Pantalla i controls

The front panel features a dual LED display and control buttons:
- Visualització de PV (valor de procés): Shows the current measured weight or force.
- Pantalla SV (valor establert): Shows the configured setpoint or target value.
- Unit Indicators: g, kg, T (grams, kilograms, tons) to indicate the measurement unit.
- AL1, AL2, AL3 Indicators: Show the status of the alarm/relay outputs.
- Botó SET: S'utilitza per entrar al mode de programació i confirmar la configuració.
- /RST (Reset) Button: Used for resetting values or functions.
- Botons amunt / avall: Used to navigate menus and adjust parameter values.
6.2 Funcions bàsiques
- Tare Weight Removal: Use the /RST button or a configured external terminal to zero out the current weight, effectively removing the container weight.
- Display Correction: The device supports calibration and correction functions to ensure accurate readings. Refer to the detailed manual for calibration procedures.
- 6-Way Switch Control: The controller offers versatile control options for start/stop, fast forward/reverse, and other functions relevant to filling or batching processes. These are typically configured through the device's settings.
7. Manteniment
To ensure the longevity and optimal performance of your MYPIN LH86-RR4D controller, follow these maintenance guidelines:
- Neteja: Regularly wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no liquids enter the device.
- Inspecció: Comproveu periòdicament totes les connexions del cablejat per comprovar si estan ben ajustades i si hi ha signes de desgast o corrosió.
- Medi ambient: Maintain a clean, dry, and stable operating environment within the specified temperature and humidity ranges.
- Calibració: If accuracy drifts over time, recalibrate the device according to the procedures outlined in the full instruction manual.
8. Solució De Problemes
If you encounter issues with your LH86-RR4D controller, consider the following common problems and solutions:
- Sense pantalla/alimentació: Comproveu la connexió de la font d'alimentació i assegureu-vos que el volumtage is within the 90-260V AC/DC range. Verify that the power switch (if external) is on.
- Lectures inexactes: Ensure load cells are correctly wired and calibrated. Check for mechanical interference with the weighing platform. Verify that the load cell capacity matches the application.
- No Communication (RS485/RS232): Check the wiring for RS485 A/B or RS232 connections. Verify communication settings (baud rate, parity, data bits) on both the controller and the connected device.
- Relay Outputs Not Activating: Check the setpoints (SV) and ensure they are correctly configured relative to the process value (PV). Verify the wiring of external devices connected to the relay outputs.
- Lectures inestables: Check for electrical noise or interference. Ensure proper grounding. Verify load cell integrity and connections.
For more detailed troubleshooting steps and error codes, please consult the comprehensive English manual included with your product.
9. Consells d'usuari
- Modbus 485 Connectivity: The LH86-RR4D controller supports RS485 communication, which is commonly used for Modbus RTU protocols. This allows for integration with PLCs and other industrial control systems for data exchange and remote control.
- Protecció del medi ambient: For optimal performance and longevity, especially in harsh industrial environments, consider housing the controller in a protective enclosure to shield it from dust, moisture, and extreme temperatures.
10. Garantia i Suport
This product is covered by a standard manufacturer's warranty against defects in materials and workmanship. For warranty claims, technical support, or service inquiries, please contact your original point of purchase or the manufacturer's customer service. Keep your purchase receipt as proof of purchase.