1. Introducció

The ANENG MH16 is a versatile and high-precision insulation resistance tester designed for measuring insulation resistance, AC voltage, i DC voltage. It is suitable for a wide range of applications including testing transformers, motors, cables, switches, and electrical appliances. This manual provides essential information for safe and effective operation of your ANENG MH16 Insulation Resistance Meter.

2. Informació de seguretat

WARNING: Always ensure the circuit under test has no electrical presence before performing insulation resistance tests. Wear high-voltage insulating gloves during testing.

  • Do not use accessories that are not provided by the original factory to avoid danger.
  • Long short circuit at the measuring end shall not exceed 10 seconds.
  • Measuring continuous working time should not exceed 3 hours.
  • Always follow local safety regulations and use appropriate personal protective equipment (PPE) when working with electrical systems.
  • Do not operate the device if it appears damaged or is not functioning properly.

3. Configuració

3.1 Contingut del paquet

Verifiqueu que tots els elements siguin presents al vostre paquet:

  • 1 x Caixa d'embalatge
  • 1 x bossa d'emmagatzematge
  • 1 x ANENG MH16 Insulation Resistance Tester
  • 1 x Manual d'usuari
  • 2 x Alligator clips
  • 1 x Pen line (test leads)
ANENG MH16 package contents including tester, storage bag, manual, alligator clips, and test leads.
Figure 3.1: ANENG MH16 Package Contents

3.2 Producte acabatview (Panel Function Introduction)

Familiarize yourself with the components and controls of your ANENG MH16:

Diagram of ANENG MH16 with numbered parts: 1. Line terminal L, 2. Shielded terminal G/AC voltage measurement ground terminal, 3. AC and DC voltage measurement V terminal, 4. Ground terminal E, 5. External power jack, 6. Backlit digital display, 7. Instrument strap hole, 8. TEST: High voltage start button, 9. HOLD: Data hold button, 10. BLCTR: Backlight button, 11. High voltage indicator, 12. Power switch, 13. Function knobs, 14. 2500V insulation resistance, 15. 1000V insulation resistance, 16. 500V insulation resistance, 17. AC voltage, 18. DC voltage.
Figure 3.2: ANENG MH16 Panel Functions
  1. Line terminal L
  2. Shielded terminal G/AC voltage measurement ground terminal
  3. CA i CC voltage measurement V terminal
  4. Ground terminal E
  5. Presa d'alimentació externa
  6. Pantalla digital retroil·luminada
  7. Forat de la corretja de l'instrument
  8. TEST: High voltage botó d'inici
  9. HOLD: botó de retenció de dades
  10. BLCTR: Backlight button
  11. Vol. Alttage indicador
  12. Interruptor d'alimentació
  13. Function knobs
  14. 2500V insulation resistance
  15. 1000V insulation resistance
  16. 500V insulation resistance
  17. AC voltage
  18. DC voltage

3.3 Instal·lació de la bateria

The ANENG MH16 requires 6 AA batteries (not included) for operation. It can also be powered by an external 12V DC power supply with a current greater than 600mA (adapter not included).

  1. Unscrew the screws on the back cover of the device.
  2. Obriu amb cura la coberta posterior.
  3. Inseriu 6 piles AA, assegurant la polaritat correcta.
  4. Replace the back cover and screw it securely.
Image showing the back of the ANENG MH16 with the battery compartment open and batteries being inserted.
Figura 3.3: Instal·lació de la bateria

4. Instruccions de funcionament

4.1 Power On/Off and Backlight

  • To power on the device, turn the function knob (13) to the desired measurement mode.
  • To power off, turn the function knob to the 'OFF' position.
  • Press the 'BLCTR' button (10) to toggle the backlight display on or off for improved visibility in various lighting conditions.

4.2 Funció de retenció de dades

  • Press the 'HOLD' button (9) to freeze the current measurement value on the display. This is useful for recording readings in hard-to-reach areas.
  • Press 'HOLD' again to release the held value and resume live measurement.

4.3 Prova de resistència d'aïllament

Important: Always wear high-voltage insulating gloves during insulation resistance testing.

  1. Connect the test leads: Plug the red test lead into the 'L' terminal (1) and the black test lead into the 'E' terminal (4). Attach the alligator clips to the test leads.
  2. Turn the function knob (13) to the desired insulation resistance voltage (500 V, 1000 V o 2500 V).
  3. Connect the test probes (alligator clips) to the circuit or component under test. Ensure the circuit has no electrical presence before connecting.
  4. Press the 'TEST' button (8) to initiate the insulation resistance measurement. The high voltage indicator (11) will illuminate.
  5. Observe the reading on the backlit digital display (6).
  6. Interpretació:
    • Values below 0.5 GΩ (500 million ohms) may indicate a risk of electrical leakage.
    • An 'OL' (Overload) reading indicates an open circuit or very high resistance, typically signifying good insulation.
  7. The device features automatic discharge after the test is completed.
Image showing the ANENG MH16 performing an insulation resistance test on a freezer, with test leads connected.
Figure 4.1: Insulation Resistance Test on a Freezer
Image showing the ANENG MH16 performing an insulation resistance test on a power strip, with test leads connected to live and ground wires.
Figure 4.2: Insulation Resistance Test on a Power Strip

Video 4.1: Demonstration of Insulation Resistance Testing with ANENG MH16

4.4 AC Voltage Mesura

  1. Switch the function knob (13) to the 'ACV' mode (17).
  2. Connect the test probes to the AC power source (e.g., wall outlet).
  3. Llegeix l'AC voltage value on the display. The tester's reading will follow the input voltage changes, demonstrating its accuracy.
Image showing the ANENG MH16 measuring AC voltage from a wall outlet, displaying '0229'.
Figura 4.3: AC Voltage Measurement (Example: 220V household voltage)

4.5 DC Voltage Mesura

  1. Switch the function knob (13) to the 'DCV' mode (18).
  2. Align the test probes with the positive and negative terminals of the DC power source (e.g., a 3V battery).
  3. Llegeix el vol DCtage value on the display. The test is very accurate.
Image showing the ANENG MH16 measuring DC voltage from a 3V battery, displaying '0003'.
Figura 4.4: DC Voltage Measurement (Example: 3V battery)

5. Especificacions

Funció Interval Precision / Additional Info
Volum de sortidatage 500 V/1000 V/2500 V ±10%
ACV AC voltage 0 V ~ 700 V ± (1% + 6d)
DCV DC voltage 0 V ~ 1000 V ± (1% + 5d)
Resistència d'aïllament 1MΩ~50GΩ Automatic shutdown: 15 min no operation
Pes 542 g
Material ABS/Silicona
Model de bateria 1.5V AA battery*6 (without shipment)
Font d'alimentació externa Charger connection with rated output voltage 12V and current greater than 600mA
Descàrrega automàtica
Retenció de dades
Backlit bright screen
Indicador de baixa potència

5.1 Insulation Resistance Parameter Details

Voltage Interval Resistència a les caigudes Precisió bàsica
Resistance 500V 0.000 ~ 4.99 GΩ 1 MΩ ±20%
Resistance 1000V 0.000 ~ 10.00 GΩ 2 MΩ ±20%
Resistance 2500V 0.000 ~ 49.99 GΩ 5 MΩ ±20%

6. Manteniment

  • Mantingueu el dispositiu net i sec. Netegeu-lo amb un drap suau i sec.amp tela. No utilitzeu netejadors abrasius ni dissolvents.
  • Store the device in its storage bag in a cool, dry place when not in use.
  • Replace batteries when the low power prompt appears to ensure accurate readings.
  • Regularly inspect test leads and probes for any signs of wear or damage. Replace immediately if damaged.

7. Solució De Problemes

Sense pantalla/Engegada:
Check battery installation and ensure batteries are fresh. Verify the power switch is in the 'ON' position.
Lectures inexactes:
Ensure test leads are properly connected and not damaged. Verify the correct measurement mode is selected. Check for external interference.
'OL' Reading (Insulation Test):
This indicates an open circuit or very high resistance, which is normal for good insulation. If expected to be a lower value, check connections.
Low Insulation Resistance Reading:
If the insulation resistance is unexpectedly low (e.g., below 0.5 GΩ for a freezer), it indicates a potential leakage or fault in the insulation. Consult a qualified electrician.

8. Consells d'usuari

  • Always double-check your connections before initiating a test, especially for high voltage measurements, to ensure safety and accuracy.
  • Utilize the 'HOLD' function to easily record stable readings without needing to keep the probes in place, which can be particularly helpful in awkward positions.
  • The silicone sheath provides anti-drop protection, but always handle the instrument with care to prolong its lifespan.
  • For consistent results, perform measurements in a stable environment free from excessive humidity or extreme temperatures.

9. Garantia i Suport

For any product-related inquiries, technical support, or warranty claims, please contact ANENG customer service. Refer to the product packaging or the official ANENG weblloc per obtenir dades de contacte.


ANENG MH16 High Voltage Insulation Resistance Tester & Megohmmeter Demo

ANENG MH16 High Voltage Insulation Resistance Tester & Megohmmeter Demo

2:59 • 1280×720 • demostració

Documents relacionats - MH16

Preview ANENG MH16 Resistance Meter User Manual: Features, Specifications, and Operation
Comprehensive user manual for the ANENG MH16 Resistance Meter, detailing its features, technical specifications, safe operation, and maintenance for accurate resistance and voltage proves.
Preview Manual d'usuari del provador de resistència d'aïllament ANENG MH12
Manual d'usuari complet per al provador de resistència d'aïllament ANENG MH12, que detalla les especificacions, les precaucions de seguretat, les instruccions d'ús i els procediments de mesura per a les proves de resistència d'aïllament.
Preview ANENG MH12 Insulation Resistance Tester Manual: 1000V, 2500V, 5000V Specifications & Operation
Comprehensive user manual for the ANENG MH12 series insulation resistance testers (1000V, 2500V, 5000V). Covers safety precautions, general description, technical specifications, appearance, measurement procedures for insulation resistance, AC/DC voltage, DAR, and PI, along with data handling and battery replacement.
Preview ANENG 1000V/2500V/5000V Series Insulation Resistance Tester User Manual
Comprehensive user manual for the ANENG 1000V, 2500V, and 5000V series Insulation Resistance Testers, covering safety, operation, technical specifications, and measurement procedures for electrical equipment.
Preview ANENG MH10 Digital Insulation Resistance Tester - Operating Instructions and Safety Guide
Comprehensive operating instructions, safety specifications, technical parameters, and troubleshooting for the ANENG MH10 Digital Insulation Resistance Tester. Learn how to safely and effectively use this high-voltage electrical equipment test instrument.
Preview ANENG MH15 高精度绝缘电阻测试仪使用说明书
ANENG MH15是一款高精度绝缘电阻测试仪,提供多种测量功能,包括直流/交流电压、电阻、通断、二极管和绝缘电阻。本手册详细介绍了仪器的操作、安全信息和技术规格。