SY JDM11-6H, JDM11-5H

Manual d'usuari del comptador d'acumulació digital JDM11-6H / JDM11-5H

Model: JDM11-6H, JDM11-5H | Brand: SY

1. Producte acabatview

The SY JDM11-6H and JDM11-5H are versatile digital accumulation counters designed for industrial applications. These electronic counters feature a clear LED display, power failure memory, and a resettable function, making them suitable for various counting tasks. They can be configured for no-voltage counting (contact signal), voltage counting, or sensor-based counting.

Vídeo: Acabatview of the JDM11-6H Digital Counter, showcasinel seu disseny i la seva funcionalitat bàsica.

2. Especificacions

CaracterísticaDescripció
Tipus6-digit Digital Accumulation Counter
Power Supply (Source)AC220V 50/60Hz (Common), also available in 38V, 24V, 110V, 12V, 6.3V
Count SignalSwitching type (Contact, Non-contact)
Count Speed10 Hz (màxim)
Funció de memòriaPower failure memory recovery
Restablir FuncióManual reset button on front panel
MostraLED large screen
Subministraments de bricolatgeElèctric
CertificacióCE
Bateria inclosaNo
Substància química molt preocupantCap

Dimensions

  • JDM11-5H: 96 mm (longitud) x 46 mm (amplada) x 35 mm (alçada)
  • JDM11-6H: Front Panel: 57mm (Length) x 40mm (Width) x 31mm (Height). Overall Depth: 87mm. Terminal Height: 71mm. Terminal Width: 20.5mm. Terminal Height: 11mm.
Dimensions of JDM11-5H counter
Figure 1: JDM11-5H Counter Dimensions.
Front panel dimensions of JDM11-6H counter
Figure 2: JDM11-6H Front Panel Dimensions.
posterior view and terminal dimensions of JDM11-6H counter
Figure 3: JDM11-6H Rear View and Terminal Dimensions.

Associated Components (Exampells)

  • Proximity Switches: E3F-DS30C4, NJK-5002C, LJ12A3-23Z-BX, E3F-DS30C4, CDD-40N, CDD11N, TL-W5MC1
JDM11-6H counter with E3F-DS30C4 proximity switch
Figure 4: JDM11-6H Counter with E3F-DS30C4 Proximity Switch.
JDM11-6H counter with NJK-5002C proximity switch, DC24V
Figure 5: JDM11-6H Counter with NJK-5002C Proximity Switch (DC24V).

3. Configuració i instal·lació

Muntatge

The JDM11 series counters are designed for panel mounting. Refer to the dimension diagrams (Figures 1, 2, 3) for appropriate cutout sizes and mounting hole locations.

Instruccions de cablejat

Ensure all power is disconnected before attempting any wiring. The counter features screw terminals for secure connections. Access the terminals by removing the rear cover (typically secured by 4 screws).

3.1. No Voltage Counting (Contact Signal)

This method is used when the counting signal is provided by a switch that does not supply voltage, such as a mechanical switch, micro switch, travel switch, button, or a 2-wire proximity switch.

  • Connect the counting signal to terminals 1 and 2.
  • Connect the working power supply to terminals 3 and 4.
Wiring diagram for no voltage counting and voltage counting
Figure 6: Wiring Diagram for No Voltage Counting (Contact Signal) and Voltage Counting (Voltage Signal).

3.2. With Voltage Counting (Voltage Signal)

This method is used when the counting signal itself carries a voltage, such as a power-on signal, level signal, pulse signal, or PLC signal. It is critical that the counting voltage i la font d'alimentació voltage són coherents.

  • Connecteu el voltage signal to the appropriate input terminals as indicated in the wiring diagram (Figure 6).
  • Ensure the working power supply is connected to terminals 3 and 4, matching the signal voltage.

3.3. Sensor Counting

For sensor-based counting, a sensor (e.g., photoelectric switch, proximity switch, Hall switch, magnetic switch) is used. NPN normally open sensors are generally recommended.

  • Connect the sensor's output to terminals 1, 2, and 3 as shown in the diagram.
  • Connect the working power supply for the counter to terminals 4 and 5.
  • The sensor itself typically requires a DC6-36V power supply.
Wiring diagram for sensor counting with PNP type sensor
Figure 7: Wiring Diagram for Sensor Counting (PNP Type Sensor).

4. Instruccions de funcionament

4.1. Encès

Once correctly wired and mounted, apply power to the counter. The LED display will illuminate, typically showing '000000' or the last saved count if power failure memory is active.

4.2. Counting Operation

The counter will accumulate counts based on the input signals received through the configured wiring method (contact, voltage, or sensor). Each valid signal pulse will increment the displayed count.

4.3. Resetting the Counter

To reset the displayed count to zero, press the 'RESET' button located on the front panel of the counter.

4.4. Power Failure Memory

The JDM11 series counters are equipped with a power failure memory function. In the event of a power outage, the last recorded count will be retained and automatically restored when power is re-established.

Interna view of counter highlighting smart chip and power failure memory
Figura 8: Intern view highlighting the smart chip for power failure memory.

5. Manteniment

  • Keep the counter clean and free from dust and debris. Use a soft, dry cloth for cleaning.
  • Ensure all wiring connections remain secure. Periodically check screw terminals for tightness.
  • Avoid exposing the device to excessive moisture, extreme temperatures, or corrosive environments.
  • Do not attempt to open the device for internal repairs unless you are a qualified technician.

6. Solució De Problemes

  • Counter not displaying or not powering on:
    - Check the power supply connection to terminals 3 and 4. Ensure the voltage matches the counter's specified input (e.g., AC220V, DC24V).
    - Verify that the power source is active.
  • Counter not counting:
    - Confirm that the counting signal is correctly wired to terminals 1 and 2 (for contact/voltage signals) or 1, 2, 3 (for sensor signals).
    - Ensure the type of counting signal (no voltage, voltage, or sensor) matches the wiring configuration.
    - For voltage counting, verify that the counting signal voltage is consistent with the counter's power supply voltage.
    - For sensor counting, check if the sensor is properly powered (DC6-36V for NPN normally open) and functioning correctly. Ensure the sensor is detecting objects within its sensing distance.
    - Check if the count speed of the input signal exceeds the counter's maximum (10Hz).
  • Incorrect count:
    - Review the wiring for any loose connections or short circuits.
    - Ensure the input signal is clean and free from electrical noise that could cause false counts.
  • Reset button not working:
    - Ensure the button is not physically stuck. If the issue persists, contact support.

7. Consells d'usuari

  • Verifiqueu el cablejat: Always double-check your wiring against the diagrams provided for your specific counting method (no-voltage, voltage, or sensor) before applying power. Incorrect wiring is a common cause of malfunction.
  • Selecció del sensor: When using a sensor, ensure it is compatible with the counter (e.g., NPN normally open) and that its power supply is correctly provided and matches the counter's requirements if applicable.
  • Consideracions ambientals: While robust, protecting the counter from excessive dust, moisture, and vibration will prolong its lifespan and ensure reliable operation.

8. Garantia i Suport

For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. Keep your purchase receipt or order details handy when contacting support.


CNAON JDM11-6H Electronic Counter Feature Demonstration | Digital Display Counter with Power-Off Memory

CNAON JDM11-6H Electronic Counter Feature Demonstration | Digital Display Counter with Power-Off Memory

0:48 • 720×960 • feature_demo

Documents relacionats - JDM11-6H

Preview Manual de servei tècnic de l'aire condicionat per conductes GREE sèrie FG
Aquest manual de servei tècnic proporciona informació completa per a les unitats d'aire condicionat per conductes de la sèrie FG de GREE (sèrie A i B), que cobreix els detalls del model, la instal·lació, els sistemes elèctrics, el funcionament, la resolució de problemes, el manteniment i el desglossament de les peces per a capacitats que van des de 2.3 kW fins a 16 kW.
Preview KOBALT Non-Contact Voltage Tester AC-6H User Manual
Comprehensive user manual for the KOBALT AC-6H Non-Contact Voltage Tester, including specifications, operation instructions, safety guidelines, troubleshooting, and maintenance tips. This device detects AC voltage from 50V to 1000V and is designed for safe and reliable electrical testing.
Preview Growatt ARK Alt VolumtagManual d'usuari del sistema de bateries e | Instal·lació, funcionament i seguretat
Manual d'usuari complet per al Growatt ARK High VoltagSistema de bateries e, que cobreix la instal·lació, el funcionament, el manteniment, les pautes de seguretat i les especificacions tècniques de la bateria ARK 2.5H-A1 i el controlador HVC 60050-A1.
Preview Manual d'usuari de l'inversor híbrid AXITEC AXIhycon
This user manual provides comprehensive instructions for the installation, operation, and maintenance of the AXITEC AXIhycon series hybrid inverters, including models 5H, 6H, 8H, and 10H. It covers safety precautions, system overview, LED indicators, mounting procedures, electrical connections, commissioning, troubleshooting, and technical specifications for three-phase systems.
Preview Della Portable Air Conditioner Instruction Manual (048-OPAC-5H, 048-OPAC-6H)
Comprehensive instruction manual for the Della 048-OPAC-5H and 048-OPAC-6H portable air conditioners. Covers installation, operation, safety, maintenance, troubleshooting, and disposal.
Preview Pentel HI-POLYMER SUPER LEAD Material Safety Data Sheet (MSDS)
Material Safety Data Sheet (MSDS) for Pentel HI-POLYMER SUPER LEAD pencil leads, providing information on identification, hazards, handling, storage, and disposal.