RCYAGO YY-1070

YAGO YY-1070 7-in-1 Water Quality Tester Instruction Manual

Model: YY-1070 | Brand: RCYAGO

1. Introducció

The YAGO YY-1070 is a versatile 7-in-1 multi-functional water quality tester designed for comprehensive analysis of various water sources. It accurately measures Free Available Chlorine (FAC), pH, Salinity, Oxidation-Reduction Potential (ORP), Total Dissolved Solids (TDS), Electrical Conductivity (EC), and Temperature. This device is ideal for monitoring water quality in swimming pools, hot tubs, spas, aquariums, hydroponic systems, drinking water, and more, ensuring optimal conditions and safety.

YAGO YY-1070 7-in-1 Water Quality Tester showing all functions
Figure 1: YAGO YY-1070 7-in-1 Water Quality Tester highlighting its multiple measurement capabilities.

2. Producte acabatview

Característiques principals:

Què hi ha a la caixa:

Contents of the YAGO YY-1070 package including tester, calibration solutions, and manual
Figure 2: Package contents of the YAGO YY-1070 tester.

3. Configuració

3.1 Instal·lació de la bateria

  1. Unscrew the battery compartment cover located at the top of the device.
  2. Insert 4*1.5V LR44 button batteries, ensuring correct polarity.
  3. Securely screw the battery compartment cover back on.
Diagram showing the YAGO YY-1070 with labeled parts including battery compartment
Figure 3: Labeled components of the YY-1070, including the battery compartment.

3.2 Comprovació inicial

  1. Press the 'ON/OFF' button to power on the device.
  2. The LCD display will light up, showing various measurement parameters.
  3. Press the 'MODE/CAL' button repeatedly to cycle through the different measurement modes (pH, TDS, Salt, EC, ORP, FAC, Temp) to familiarize yourself with the display.
  4. Remove the protective cap from the probe before use.
Video 1: Product demonstration showing power-on and mode switching.

4. Instruccions de funcionament

4.1 Mesura bàsica

  1. Ensure the device is powered on and the protective cap is removed from the probe.
  2. Immerse the probe into the water sample you wish to test. Ensure the probe is fully submerged.
  3. Press the 'MODE/CAL' button to select the desired measurement parameter (e.g., pH, FAC, Salt).
  4. Wait for the reading on the LCD display to stabilize. The reading will show the measured value and temperature.
  5. For accurate FAC readings, ensure the pool water pH is between 6.5-8 and ORP is between 487-840mV.
YAGO YY-1070 measuring water in a glass, with applications for pools, hot springs, and spas
Figure 4: The YY-1070 in use for water quality measurement.

4.2 Funció de retenció de dades

4.3 Temperature Unit Conversion

Diagram showing short press for data hold and long press for temperature unit conversion on the YY-1070
Figure 5: Functions of the HOLD/TEMP button.

5. Calibració

The YAGO YY-1070 is factory-calibrated for all functions. It is recommended to recalibrate the meter every 2-4 weeks to maintain optimal accuracy, or if you suspect inaccurate readings.

5.1 Calibration Solutions

Use standard buffer solutions for calibration:

Calibration buffer solutions for pH and ORP
Figure 6: Calibration buffer solutions for pH and ORP.

5.2 Procediment de calibratge

For detailed calibration steps for each parameter (pH, ORP, EC, TDS, Salinity), please refer to the specific instructions provided in the physical instruction manual included with your product. The general process involves:

  1. Prepare the appropriate calibration solution.
  2. Immerse the probe into the calibration solution.
  3. Enter calibration mode by long-pressing the 'MODE/CAL' button (or as specified in the manual).
  4. Adjust the reading to match the known value of the calibration solution.
  5. Confirm calibration and exit the mode.

6. Especificacions

ParàmetreIntervalResolucióPrecisió
pH0.1-14.0 pH0.1 pH±0.1 pH
FAC (Free Available Chlorine)0.1-4.0 ppm0.1 ppm±1 ppm
La salinitat0-10000 ppm, 10.1-200.0 ppt, 0.01%-25.00%1 ppm, 10 ppm±2% FS
EC (Electrical Conductivity)0-10000 uS/cm, 10.01-19.99 mS/cm, 20.1-400.0 mS/cm1 uS/cm, 10 uS/cm, 0.01 mS/CM±2% FS
TDS (sòlids dissolts totals)0-10000 ppm, 10.1-200.0 ppt1 ppm, 10 ppm±2% FS
ORP (Potencial d'oxidació-reducció)±999 mV1 mV±15 mV
Temperatura0.0 ℃ -60.0 ℃ (32.0 ℉ -140 ℉)0.1 ℃ / 0.1 ℉± 0.5 ℃

7. Manteniment

Close-up of the YY-1070 probe, showing it is highly sensitive, removable, and replaceable
Figure 7: Removable and replaceable probes for easy maintenance.

8. Solució De Problemes

8.1 FAC Value Displays 0 or '----'

Problema: The Free Available Chlorine (FAC) value is displayed as 0 or '----'.

Solució: For the FAC value to display normally, the swimming pool water's pH should be between 6.5-8 pH, and the ORP should be between 487-840 mV. If either the pH or ORP value is outside this specified range, the FAC reading will not be displayed correctly.

ORP Meter explanation with remarks on pH and ORP ranges for normal FAC display
Figure 8: Conditions for normal FAC display based on pH and ORP values.

8.2 Discrepancy with Reagent Test Papers

Problema: The device detects 0 residual chlorine, but a reagent test paper shows a different value.

Solució: The detection principles of the YAGO YY-1070 digital tester and traditional test papers are different. Test papers often have a larger margin of error and cannot be accurately compared with the precise readings provided by electronic equipment.

9. Consells d'usuari

TDS value chart indicating water purity levels and examples of water sources
Figure 9: TDS value chart for water quality assessment.
Images showing various applications of the water quality tester, including drinking water, fish tanks, and hydroponics
Figure 10: Wide range of applications for the YY-1070 tester.

10. Garantia i assistència

Per obtenir informació sobre la garantia, assistència tècnica o consultes sobre el servei, poseu-vos en contacte directament amb el venedor o el fabricant. Conserveu el rebut de compra com a comprovant de compra.


RCYAGO YY-1070 7-in-1 Digital Water Quality Tester: pH, Salt, TDS, EC, Temp, ORP, FAC Meter

RCYAGO YY-1070 7-in-1 Digital Water Quality Tester: pH, Salt, TDS, EC, Temp, ORP, FAC Meter

0:27 • 1280×720 • visual_overview

Documents relacionats - YY-1070

Preview Manual d'instruccions de l'analitzador intel·ligent d'oxigen dissolt tipus bolígraf DO-9100
Aquest document proporciona instruccions per a l'analitzador intel·ligent d'oxigen dissolt tipus bolígraf DO-9100, que cobreix les seves característiques, paràmetres tècnics, funcionament, manteniment i resolució de problemes.
Preview Manual d'operació del mesurador de qualitat de l'aigua de Noyafa
Manual d'operació per a mesuradors de qualitat d'aigua tipus bolígraf Noyafa, que cobreix la resolució de problemes, els punts d'atenció, la garantia, l'autorització de devolució i les especificacions detallades dels paràmetres per a diversos models.
Preview Pen Type Water Quality Meter Operation Manual: pH, TDS, EC, SALT, ORP Measurement
Comprehensive operation manual for the pen-type water quality meter. Covers troubleshooting, calibration, parameters, and usage for measuring pH, TDS, EC, SALT, ORP, H2, and S.G. Includes detailed guides for models like EZ9901, C-600, and more.
Preview Manual d'instruccions del mesurador de pH intel·ligent de la sèrie YY-103
Manual d'instruccions complet per al mesurador de pH intel·ligent de la sèrie YY-103, que cobreix els paràmetres, les funcions dels diferents models, el funcionament, l'ús de l'aplicació i els procediments de calibratge. Inclou detalls sobre els tipus d'elèctrodes, les especificacions i la garantia de qualitat.
Preview YIERYI YY-1104 6-in-1 Soil Meter: User Manual and Specifications
Comprehensive guide for the YIERYI YY-1104 6-in-1 Soil Meter, covering its features, technical specifications, usage instructions, and important precautions for measuring soil fertility, moisture, and temperature.
Preview Pentair Xport Drain System Installation Guide for Pools
Comprehensive installation guide for the Pentair Xport Drain System, covering concrete, fiberglass, and vinyl pools. Includes safety precautions, installation methods, parts lists, and technical support information.