Introducció
The CEM DT-663H (and DT-660B) is a high-precision, multifunctional handheld digital multimeter designed for a wide range of electrical measurements. It features a 4000-count backlit LCD display, True RMS measurement (DT-663H model), and comprehensive overload protection. This manual provides essential information for the safe and effective operation of your multimeter.

Informació de seguretat
Sempre seguiu les precaucions de seguretat quan utilitzeu equips de prova elèctrica. Si no ho feu, podeu patir lesions o danys al mesurador o a l'equip que s'està provant.
- Llegeix i entén totes les instruccions abans d'utilitzar.
- No apliqueu més del volum nominaltage, tal com està marcat al comptador, entre els terminals o entre qualsevol terminal i terra.
- Tingueu precaució quan treballeu amb voltagper sobre de 30 V CA RMS, 42 V pic o 60 V CC. Aquests voltagsuposen un risc de xoc.
- Inspeccioneu els cables de prova per detectar danys a l'aïllament o metall exposat abans d'utilitzar-los. Substituïu-los si estan danyats.
- Ensure the rotary switch is in the correct position for the desired measurement before connecting test leads.
- No feu funcionar el mesurador si sembla danyat o si la carcassa està oberta.
- Substituïu la bateria tan bon punt aparegui l'indicador de bateria baixa per garantir lectures precises.
- The meter is equipped with overload protection to prevent burnout, but proper usage is still critical.
Parts of the Multimeter

- Pantalla LCD: Mostra lectures de mesurament i indicadors.
- Botó MODE: Selects different measurement functions within a rotary switch position (e.g., AC/DC, Resistance/Continuity/Diode).
- Botó RANGE: Manually selects measurement range or toggles auto-ranging.
- Interruptor de funció rotatiu: Selects the primary measurement function (e.g., Voltage, Current, Resistance, Temperature).
- 10A Positive Input Jack: For high current measurements (up to 10A).
- Botó MAX/MIN: Displays maximum or minimum measured values.
- HOLD/Backlight Button: Freezes the current display reading; long press activates/deactivates backlight.
- V, Ω, Hz, CAP, Diode, Continuity, mA, µA Positive Input Jack: Per al voltage, resistance, frequency, capacitance, diode test, continuity, and low current measurements.
- Presa d'entrada COM: Entrada comuna (negativa) per a totes les mesures.
Configuració i funcionament bàsic
Instal·lació de la bateria
The multimeter requires batteries (not included). To install or replace batteries:
- Assegureu-vos que el multímetre estigui APAGAT.
- Localitzeu la tapa del compartiment de la bateria a la part posterior de la unitat.
- Use a screwdriver to remove the screw(s) securing the cover.
- Insert the correct type and number of batteries, observing polarity (+/-).
- Replace the cover and secure with the screw(s).
Connexió de cables de prova
Always connect the black test lead to the COM jack. Connect the red test lead to the appropriate input jack based on the measurement type:
- Per al voltage (V), Resistance (Ω), Frequency (Hz), Capacitance (CAP), Diode Test, Continuity, mA, or µA measurements: Connect the red lead to the VΩHzCAPmAµA jack (8).
- For high current (10A) measurements: Connect the red lead to the 10A jack (5).
Instruccions de funcionament
The CEM DT-663H offers a variety of measurement functions. Always select the correct function and range before making a measurement.
General Measurement Steps:
- Connect the test leads correctly (black to COM, red to appropriate input).
- Turn the rotary function switch (4) to the desired measurement function.
- If necessary, press the MODE button (2) to select AC/DC or other sub-functions.
- If the meter is not auto-ranging, select an appropriate range using the RANGE button (3).
- Connect the test probes to the circuit or component to be measured.
- Read the value on the LCD display (1).
- After measurement, disconnect the probes and turn the rotary switch to OFF.
Specific Measurement Functions:



Voltage (AC/DC) Measurement:
- Turn the rotary switch to 'V~' for AC Voltage or 'V-' for DC Voltage.
- Connect the red probe to the VΩHzCAPmAµA jack and the black probe to the COM jack.
- Connect the probes in parallel across the component or circuit to measure voltage.
Current (AC/DC) Measurement (DT-663H only):
- Turn the rotary switch to 'A~' for AC Current or 'A-' for DC Current.
- Connect the red probe to the 10A jack for high current or VΩHzCAPmAµA jack for mA/µA, and the black probe to the COM jack.
- Connect the probes in series with the circuit to measure current. Ensure the circuit is broken to insert the meter.
Resistance (Ω) Measurement:
- Turn the rotary switch to 'Ω'.
- Connect the red probe to the VΩHzCAPmAµA jack and the black probe to the COM jack.
- Connect the probes across the component to measure resistance. Ensure the circuit is de-energized.
Prova de continuïtat:
- Turn the rotary switch to 'Ω' and press MODE until the continuity symbol (speaker icon) appears.
- Connect the red probe to the VΩHzCAPmAµA jack and the black probe to the COM jack.
- Connect the probes across the circuit or component. A beep indicates continuity.
Prova de díode:
- Turn the rotary switch to 'Ω' and press MODE until the diode symbol appears.
- Connect the red probe to the VΩHzCAPmAµA jack and the black probe to the COM jack.
- Connect the probes across the diode. The display shows the forward voltage gota.
Capacitance (CAP) Measurement (DT-663H only):
- Turn the rotary switch to 'CAP'.
- Connect the red probe to the VΩHzCAPmAµA jack and the black probe to the COM jack.
- Connect the probes across the capacitor. Ensure the capacitor is discharged before testing.
Frequency (Hz) Measurement (DT-663H only):
- Turn the rotary switch to 'Hz'.
- Connect the red probe to the VΩHzCAPmAµA jack and the black probe to the COM jack.
- Connect the probes to the circuit to measure frequency.
K-type Temperature Measurement (DT-663H only):
- Turn the rotary switch to '°C/°F'.
- Connect the K-type thermocouple to the appropriate input jacks (usually marked for temperature).
- Place the thermocouple tip on the object to measure its temperature.
Battery Test (DT-663H only):
- Turn the rotary switch to the battery test function (usually indicated by a battery symbol).
- Connect the red probe to the VΩHzCAPmAµA jack and the black probe to the COM jack.
- Connect the probes to the battery terminals, observing polarity. The display will show the battery voltage.
Funcions especials:
- MANTENIR: Press the HOLD button (7) to freeze the current reading on the display. Press again to release.
- Il·luminació de fons: Long press the HOLD/Backlight button (7) to turn the display backlight on or off.
- MÀXIM / MÍN: Press the MAX/MIN button (6) to cycle through maximum, minimum, and current readings.
- Rang automàtic/manual: The meter typically defaults to auto-ranging. Press the RANGE button (3) to switch to manual ranging, then press again to cycle through ranges. Long press to return to auto-ranging.
Manteniment
Un manteniment adequat garanteix la longevitat i la precisió del vostre multímetre.
- Neteja: Netegeu el cas amb l'anunciamp drap i detergent suau. No utilitzeu abrasius ni dissolvents.
- Substitució de la bateria: Replace batteries promptly when the low battery indicator appears to maintain accuracy. Refer to the "Battery Installation" section for instructions.
- Substitució de fusibles: If the current measurement function stops working, the fuse may need replacement. Refer to the service manual or contact customer support for fuse specifications and replacement procedures.
- Emmagatzematge: If the meter is not used for an extended period, remove the batteries to prevent leakage. Store in a cool, dry place.
- C protectoraasing: The multimeter features a durable protective sleeve and hard rubber casing for shock and drop resistance. While robust, avoid unnecessary drops or impacts.

Resolució de problemes
| Problema | Causa possible | Solució |
|---|---|---|
| El mesurador no s'encén. | Piles gastades o instal·lades incorrectament. | Check battery polarity, replace batteries. |
| No reading or "OL" displayed. | Open circuit, incorrect range, or overloaded input. | Check connections, select higher range, ensure circuit is closed. |
| Lectures inexactes. | Low battery, incorrect function/range, or environmental factors. | Replace batteries, verify function/range, ensure stable environment. |
| La mesura de corrent no funciona. | Fusible cremat. | Replace the fuse (refer to maintenance section). |
| La retroiluminació de la pantalla no funciona. | Backlight function not activated. | Long press the HOLD/Backlight button to activate. |
Especificacions
| Característica | Detall |
|---|---|
| Model | DT-663H (also DT-660B) |
| Mostra | 4000 recomptes, LCD retroil·luminada |
| RMS veritable | Yes (DT-663H) |
| Precisió | 0.5% High Precision (DT-663H) |
| Variant | Auto/Manual Selectable |
| Funcions de mesura | Volum AC / DCtage, AC/DC Current (663H), Resistance, Capacitance (663H), Frequency (663H), K-type Temperature (663H), Diode Test, Battery Test (663H), Continuity Test, Data Hold, Max/Min |
| Protecció | Overload Protection, Intelligent Anti-burn, Double Layer Protective Casing |
| Subministraments de bricolatge | Elèctric |
| Bateria inclosa | No |
| Origen | Xina continental |

Consells per a l'usuari
- For accurate temperature readings, ensure the K-type thermocouple is properly connected and making good contact with the surface being measured.
- When measuring current, always ensure the meter is connected in series with the load and the circuit is de-energized before connecting the probes to avoid damage to the meter or circuit.
- Utilize the HOLD function for convenience when taking readings in hard-to-see areas.
- The backlight feature is very useful in dimly lit environments, improving readability of the display.
- Always double-check the rotary switch position and probe connections before making any measurement to prevent damage to the meter or the circuit.
Garantia i Suport
For warranty information, technical support, or service inquiries, please contact your point of purchase or the manufacturer directly. Keep your purchase receipt as proof of purchase.
This product is designed for electrical DIY supplies and professional use. Ensure you have adequate knowledge and take necessary safety precautions when operating.