1. Introducció

The CEM DT-663H is a high-precision, multifunctional handheld digital multimeter designed for a wide range of electrical measurements. This manual provides essential information for the safe and effective use of your device, including setup, operation, maintenance, and specifications. The DT-663H model features 4000 counts, 0.5% high precision True RMS measurement, auto-ranging, a backlit LCD display, and comprehensive overload protection. It is suitable for electronic repair, HVAC, electrical engineering, quality inspection, environmental testing, and scientific research/education.

CEM DT-663H Multimeter with key features highlighted
The CEM DT-663H Handheld Digital Multimeter, emphasizing its fully protected design and key features.

2. Informació de seguretat

Observeu sempre les precaucions de seguretat quan utilitzeu qualsevol equip de prova elèctrica. Si no ho feu, podeu patir lesions o danys al mesurador o a l'equip que s'està provant.

  • Seguretat general: Always ensure the meter is in good working condition before use. Do not use if damaged.
  • Voltage Límits: No apliqueu mai voltage or current that exceeds the maximum rated limits for the meter.
  • Cables de prova: Use only the provided test leads. Ensure they are in good condition, free from cracks or damage.
  • Connexió adequada: Always connect the common (COM) test lead first, then the live lead. When disconnecting, remove the live lead first, then the common lead.
  • Aïllament: Wear appropriate personal protective equipment, such as insulated gloves, when working with live circuits.
  • Circuit De-energization: Whenever possible, de-energize and lock out circuits before performing resistance, capacitance, diode, or continuity tests.
  • Protecció de sobrecàrrega: The meter features smart anti-burn and overload protection. However, always select the appropriate range and function to avoid damage.
  • Medi ambient: No feu funcionar el mesurador en atmosferes explosives ni en presència de gasos o pols inflamables.

3. Producte acabatview

The DT-663H multimeter features a robust design with a protective casing for shock resistance and durability. Its intuitive layout includes a clear LCD display and a high-quality multi-position rotary switch for function selection.

Labeled diagram of CEM DT-663H Multimeter components
Diagram of the DT-663H Multimeter with labeled components.
  1. Pantalla LCD: Mostra lectures de mesura, unitats i indicadors de funció.
  2. Botó RANGE: Used to switch between auto-ranging and manual ranging modes.
  3. Botó MODE: Selects different measurement modes within a function (e.g., AC/DC voltage, freqüència/cicle de treball).
  4. Interruptor de funció rotatiu: Main dial to select the desired measurement function (e.g., Voltage, Current, Resistance).
  5. 10A Positive Input Jack: For high current measurements (up to 10A).
  6. Botó MAX/MIN: Displays the maximum or minimum reading recorded during a measurement session.
  7. HOLD/Backlight Button: Freezes the current display reading (HOLD) or activates/deactivates the display backlight.
  8. V, Ω, Hz, CAP, Diode, Continuity, mA, µA Positive Input Jack: Per al voltage, resistance, frequency, capacitance, diode test, continuity, and low current measurements.
  9. Presa d'entrada COM: Common (negative) input jack for all measurements.
Multimeter with protective casing
The multimeter features a protective sleeve and hard rubber casing for enhanced durability and shock resistance.

4. Configuració

4.1 Instal·lació de la bateria

The DT-663H multimeter requires batteries for operation (batteries are not included). To install or replace batteries:

  1. Assegureu-vos que el multímetre estigui apagat i desconnecteu tots els cables de prova dels endolls d'entrada.
  2. Localitzeu la tapa del compartiment de la bateria a la part posterior del mesurador.
  3. Utilitzeu un tornavís per obrir el compartiment de la bateria.
  4. Insert new batteries, observing correct polarity (+ and -).
  5. Substituïu la tapa del compartiment de la bateria i fixeu-la amb el cargol.

4.2 Connexió dels cables de prova

Always use the provided test leads. Ensure they are fully inserted into the correct input jacks for the desired measurement.

  • Per a la majoria de mesures (Voltage, Resistance, Capacitance, Frequency, Diode, Continuity, mA, µA), connect the black test lead to the COM jack i el cable de prova vermell al V, Ω, Hz, CAP, Diode, Continuity, mA, µA jack.
  • For high current (10A) measurements, connect the black test lead to the COM jack i el cable de prova vermell al 10A jack.

5. Instruccions de funcionament

The DT-663H offers a variety of measurement functions. Always select the correct function and range before connecting to a circuit.

Icons representing various measurement functions
Visual representation of the multimeter's diverse measurement capabilities.

5.1 Passos bàsics de mesura

  1. Turn the rotary function switch to the desired measurement function.
  2. Connecteu els cables de prova a les preses d'entrada corresponents.
  3. Connect the test probes to the circuit or component under test.
  4. Llegiu el valor de mesura a la pantalla LCD.
  5. Use the RANGE button to switch between auto-ranging and manual ranging if needed.
  6. Premeu el botó HOLD per congelar la lectura actual a la pantalla. Premeu-lo de nou per alliberar-la.
  7. Press the HOLD button for a longer duration to activate/deactivate the backlight.
  8. Utilitzeu el botó MAX/MIN per view the maximum or minimum recorded value.

5.2 Funcions de mesura específiques

  • Volum AC / DCtage Measurement (V~ / V-): Select the 'V' position on the rotary switch. Use the MODE button to toggle between AC and DC voltage. Connect leads in parallel to the circuit.
  • DC Current Measurement (A- for DT-663H): Select the 'A' position. Ensure the red lead is in the correct current input jack (mA/µA or 10A). Connect leads in series with the circuit.
  • Resistance Measurement (Ω): Select the 'Ω' position. Ensure the circuit is de-energized. Connect leads across the component.
  • Capacitance Measurement (CAP for DT-663H): Select the 'CAP' position. Ensure the capacitor is discharged before testing.
  • Frequency Measurement (Hz% for DT-663H): Select the 'Hz' position.
  • K-type Temperature Measurement (°C/°F for DT-663H): Select the 'TEMP' position. Connect a K-type thermocouple to the appropriate jacks.
  • Prova de díode: Select the diode symbol position. Connect leads across the diode.
  • Prova de continuïtat: Select the continuity symbol position. The meter will beep if continuity is detected.
  • Battery Test (for DT-663H): Select the battery test function to check battery voltage sota càrrega.
Multimeter in various usage scenarios
Examples of multimeter usage: AC voltage, DC voltage, mesures de resistència i temperatura.
Backlit LCD display of the multimeter
The backlit HD large LCD display ensures measurement results are clear and easy to read.

6. Manteniment

6.1 Neteja

Per netejar el mesurador, netegeu la carcassa amb aiguaamp drap i un detergent suau. No utilitzeu abrasius ni dissolvents. Assegureu-vos que el mesurador estigui completament sec abans d'utilitzar-lo.

6.2 Substitució de la bateria

When the battery indicator appears on the display, replace the batteries as described in the 'Battery Installation' section (4.1). Always dispose of old batteries responsibly.

6.3 Emmagatzematge

If the meter is not to be used for an extended period, remove the batteries to prevent leakage. Store the meter in a cool, dry place, away from direct sunlight and extreme temperatures.

Diagram illustrating smart anti-burn and overload protection
The multimeter features smart anti-burn and range overload protection for safer operation.

7. Solució De Problemes

  • Sense pantalla/Pantalla tènue: Check battery levels and replace if necessary. Ensure batteries are installed with correct polarity.
  • Lectures incorrectes: Verify that the correct function and range are selected. Ensure test leads are properly connected and not damaged. Check the component or circuit for proper operation.
  • Meter Does Not Respond: Turn the meter off and then on again. If the issue persists, remove and reinsert the batteries.
  • Overload Indication ('OL'): The measured value exceeds the selected range. Switch to a higher range or a different function if appropriate.

8. Especificacions

CaracterísticaEspecificació
ModelDT-663H (also DT-660B variant)
MarcaCEM
Subministraments de bricolatgeElèctric
OrigenXina continental
Nombre de visualitzacions4000 counts (DT-663H)
Precisió0.5% (DT-663H)
RMS veritableYes (DT-663H)
VariantAuto-ranging and Manual ranging
Llum de fons
Protecció de sobrecàrregaFull function range measurement overload protection
MidesVolum AC / DCtage, DC Current (663H), Resistance, Capacitance (663H), Frequency (663H), K-type Temperature (663H), Diode Test, Continuity Test, Battery Test (663H)
BateriaNo inclòs
Diagram highlighting 4000 counts and 0.5% precision for DT-663H
The DT-663H model offers 4000 counts and 0.5% high precision True RMS measurement.

9. Consells d'usuari

  • For accurate temperature readings, ensure the K-type thermocouple is properly calibrated and making good contact with the surface being measured.
  • When measuring resistance, always ensure the circuit is completely de-energized to prevent damage to the meter and ensure accurate readings.
  • The auto-ranging feature is convenient, but for very small or specific measurements, switching to manual ranging can sometimes provide faster or more stable readings.

10. Garantia i Suport

Per obtenir informació sobre la garantia, assistència tècnica o consultes sobre el servei, poseu-vos en contacte amb el punt de compra original o directament amb el fabricant. Conserveu el rebut de compra com a comprovant de compra.

Diagram showing wide application areas of the multimeter
The DT-663H multimeter is suitable for a wide range of applications including electronic repair, HVAC, and electrical engineering.

Documents relacionats - DT-663H

Preview Manual d'usuari del mesurador de gruix de recobriment CEM Pro DT-156H
Manual d'usuari complet per al CEM Coating Thickness Gauge Pro (DT-156H). Inclou informació general, característiques, especificacions, funcionament, calibratge, configuració, resolució de problemes i més.
Preview Manual d'usuari del termoanemòmetre CEM DT-90: mesura de la velocitat de l'aire i la temperatura
Manual d'usuari detallat per al termoanemòmetre CEM DT-90. Aprèn sobre les seves característiques, especificacions, funcionament i manteniment per a mesures precises de la velocitat de l'aire i la temperatura.
Preview Termòmetre digital CEM DT-612: especificacions tècniques i característiques
Informació detallada sobre el termòmetre digital CEM DT-612, incloses les seves especificacions elèctriques i ambientals, característiques i accessoris. Aquest dispositiu portàtil utilitza termoparells de tipus K per a mesures precises de temperatura.
Preview Instruccions d'ús per a CEM AC TRMS Clamp Mesurador DT-350H
Instruccions d'ús detallades i especificacions per al CEM AC TRMS Clamp Mesurador, model DT-350H. Inclou precaucions de seguretat, descripció del mesurador, especificacions i procediments de mesura.
Preview Manual d'usuari del mesurador d'humitat sense agulla CEM DT-128M
Manual d'usuari del mesurador d'humitat sense agulla CEM DT-128M, un mesurador electrònic dampIndicador de humitat per a la detecció no destructiva d'humitat en materials de construcció. Les característiques inclouen lectures ràpides, penetració en profunditat, retenció de dades, visualització MÀX/MÍN, funcions d'alarma i retroiluminació.
Preview CEM DT-5301 Digital Loop/PSC Tester: Specifications and Features
Detailed specifications, features, and electrical characteristics of the CEM DT-5301 Digital Loop and Prospective Short Circuit Current (PSC) Tester. Includes general specifications, loop resistance, prospective short current, and AC voltage mesures.