This manual provides detailed instructions for the installation, operation, and maintenance of your EARU Three Phase Tuya WiFi Smart Bi-Directional Energy Meter with 3 CT Clamps and integrated Leakage, Over/Under Voltage Protector, and Relay Switch Limit. This device is designed for precise energy monitoring and protection in three-phase electrical systems, offering smart control and data access via WiFi.

EARU Three Phase WiFi Smart Energy Meter & Protector with CT Clamps and App Interface

Figure 1: EARU Three Phase WiFi Smart Energy Meter & Protector

2. Informació de seguretat

  • La instal·lació i el manteniment només han de ser realitzats per electricistes qualificats.
  • ALWAYS turn off the main power supply before installing or servicing the device to prevent electric shock.
  • This product does not have an isolation function. Ensure power is off before any repairs.
  • The neutral wire (N) of this product is directly connected without a disconnection function.
  • The device must be wired according to the markings on the unit.
  • Although this device has protection functions, it cannot replace a normal circuit breaker. Always install a standard circuit breaker upstream for comprehensive protection.
  • Apretar tot clamp screws firmly to avoid damage to the device caused by poor contact.

3. Característiques del producte

  • Bi-Directional Energy Monitoring: Measures both forward (positive) and reverse (negative) energy consumption, ideal for solar installations.
  • Protecció integral: Inclou més de Vol.tage, sota el voltage, Over Current, Under Current, Leakage, Voltage Imbalance, Phase Shortage, and High Temperature protection.
  • Control intel·ligent: Remote control via Tuya Smart / Smart Life app.
  • Control de veu: Compatible amb Google Assistant i Amazon Alexa.
  • Temporitzadors programables: Countdown, Timed, and Recurring timer modes for automated control.
  • Memòria de fallada d'alimentació: Retains data and returns to pre-power failure state upon restoration.
  • Visualització de dades en temps real: LCD screen shows voltage, current, power, frequency, power factor, and energy consumption.
  • Configuració d'alarma: Customizable thresholds for various protection parameters.
  • Registre de dades: Records operation history and energy statistics.
Display modes and list of features

Figure 2: Key Features and Display Modes

4. Contingut del paquet

  • 1 x EARU Three Phase WiFi Smart Energy Meter & Protector Unit
  • 3 x Current Transformer (CT) Clamps (Amperage depends on model purchased)

5. Especificacions

Technical Data table

Figure 3: Technical Data

Taula 1: Especificacions del producte
AtributValor
Número de modelEASEM-G-TY-W
VoltageAC380V (L+N=AC80-240V)
Operació VoltageAC80V-400V (Single Phase)
Corrent nominal80A/120A/200A/300A/500A/750A/1000A (Depends on CT)
Freqüència nominal50/60Hz
Precisió de la mesura±1%/Class 1 (80-300A starts from 0.03A, 500-1000A starts from 0.1A)
Device Data Fresh Speed1 Time/S
App Data Fresh SpeedIf fluctuations in kWh (≥5), V (≥5V), A (≥0.8A), or Temperature (≥5°C) occur → Upload to App immediately; otherwise, upload every 5 minutes.
Consum d'energia≤1.5 W
Instal·lació35MM Din Rail
Temperatura de treball-10 ℃ ~ + 55 ℃
Temperatura d'emmagatzematge-40 ℃ ~ + 70 ℃
Humitat de treball5% ~ 95% HR
Dimensions90*72.5*60MM (L*W*H)
Tipus de visualitzacióLCD
Max kWh Record999999 kWh
Display Working TimeSempre activat
Capacitat de càrrega0.05Ib-Imax
EstàndardIEC62053-21&GB/T17215.321-2008
CertificacióCE, FCC
Garantia1 any
Dimensions del producte i paràmetres bàsics

Figura 4: Dimensions del producte

6. Instal·lació

6.1 Muntatge

The energy meter is designed for 35mm DIN rail installation. Ensure a secure fit within your electrical panel.

6.2 CT Clamp Instal·lació

The Current Transformer (CT) clamps are crucial for current measurement. Each CT clamp has an arrow or 'P1→P2' / 'K→L' marking on its body or a sticker. This indicates the direction of current flow. The CT supports bidirectional sensing. If the current direction is opposite to the CT's marking, the power reading will be negative. Ensure the CT is applied to the correct cable and its direction is consistent with your measurement needs.

CT Clamp installation diagram and dimensions table

Figura 5: CT Clamp Instal·lació i dimensions

6.3 Instruccions de cablejat

Refer to the wiring diagrams below for proper connection. Connect the AC input lines to the appropriate terminals (L1, L2, L3, N) and the CT clamps to the respective phase cables. Ensure all connections are tight and secure.

Nota important: A circuit breaker and a shunt trip device are required for the protection functions to operate. These are NOT included in the package and must be purchased separately if needed.

6.3.1 Energy Meter + Protector Wiring Diagram

Energy Meter + Protector Wiring Diagram

Figure 6: Wiring for Energy Meter with Protector Functions

For the protector function with a shunt trip release:

  • Connect the other wire of the shunt trip release to terminal 16 (Normally Open - NO).
  • Connect the neutral wire (N) from the electric meter to the common (COM) terminal 15.
  • Terminal 15 is the common contact (COM). Terminal 16 is the Normally Open (NO) contact, with a maximum load capacity of 5A.

Wiring Instructions for a Three-Phase Circuit Breaker with an Integrated 220V Shunt Trip Release:

Connect one wire of the shunt trip release to the C-phase (Phase C) point of the circuit breaker's output line. WARNING: This wire can only be connected with the circuit breaker output line, not the input line. If connected to the input line, the Shunt Trip Release will be burnt!

6.3.2 Pure Energy Meter Wiring Diagram

Pure Energy Meter Wiring Diagram

Figure 7: Wiring for Pure Energy Meter Functionality

6.3.3 Definició de la interfície

Interface Definition Table for the meter

Figure 8: Terminal Interface Definitions

7. Funcionament

7.1 Pantalla local

The device features an LCD screen that cycles through various parameters. Use the navigation buttons (Up, Down, OK) to view diferents modes de visualització i configuracions.

7.2 App Integration (Tuya Smart / Smart Life)

The meter integrates with the Tuya Smart or Smart Life app for remote monitoring and control. Follow these steps to connect your device:

  1. Download the Tuya Smart or Smart Life app from your app store.
  2. Registreu-vos o inicieu sessió al vostre compte.
  3. Ensure your device is powered on and in pairing mode (WiFi indicator blinking).
  4. In the app, tap '+' to add a new device. The app should automatically discover the device. If not, select 'Add Manually' and choose 'Breaker' or 'Socket (Wi-Fi)' under Electrical.
  5. Introduïu les credencials de la vostra xarxa Wi-Fi (cal una xarxa de 2.4 GHz).
  6. Once connected, the device will appear in your app, allowing you to view real-time data, energy statistics, operation records, and configure settings.

Video 1: App Pairing and Feature Demonstration

App screenshots showing various settings and alarm configurations

Figure 9: Tuya Smart App Interface for Monitoring and Settings

7.3 Control de veu

The device supports voice control through Google Assistant and Amazon Alexa. After linking your Tuya Smart/Smart Life account to your voice assistant, you can use commands like "Alexa/Google, Turn On The Living Room Light" (if connected to a controlled load) or inquire about energy status.

Voice Control feature with smart speakers

Figura 10: Integració del control per veu

8. Configuració

8.1 Protection and Alarm Settings

The device offers extensive customizable protection settings. These can be configured via the device's buttons or through the Tuya Smart/Smart Life app.

Summary of Alarm Settings and their default values

Figure 11: Alarm Setting Overview

Table 2: Protection and Alarm Parameters
ParàmetreRang ajustableValor per defecte
Més del voltage Límit120-300V275 V
Sota el voltage Límit80-210V175 V
Over Current Limit1-100A80A
Under Current Limit1-100A10A
Leakage Current Limit10-100 mA30 mA
Alarma d'alta temperatura10-85 ℃85℃
Three-Phase Current Imbalance Alarm10-100%20%
Voltage Three-Phase Imbalance Alarm0-100%20%
Over & Under Voltage Protection Recovery Time1-9999 segons20 s
Over & Under Current Protection Delay0000-9999 segons5s
Over & Under Current Protection Recovery Time0000-9999 segons20 s
Under & Over Voltage Protection Delay1-9999 segons3s
Lost Current Recovery Delay Time1-9999 segons20 s
Time Threshold of Lost Flow Event1-999 segons10 s
Energy Consumption Zero ClearingN/ADesactivat per defecte
Restabliment de la configuració de fàbricaN/ADesactivat per defecte

8.2 Funcions del temporitzador

The app allows you to set various timer functions to automate the device's operation:

  • Mode de compte enrere: Configureu un temporitzador perquè el dispositiu s'apagui després d'un temps especificat.
  • Mode cronometrat: Schedule specific ON/OFF times for the device.
  • Recurring Timer Mode: Set daily or weekly schedules for repeated operations.
  • A poc a poc: Configure the device to turn on for a brief period after being triggered.
Countdown, Timed, and Recurring Timer Modes

Figure 12: Timer Function Examples

9. Consells d'usuari

  • Connectivitat Wi-Fi: If you experience issues with the Wi-Fi function, ensure your router is broadcasting a 2.4GHz network. Check that the device is in pairing mode (blinking Wi-Fi indicator) and verify your Wi-Fi password in the app.
  • Configuració de protecció: Carefully configure the over/under voltage and current limits to match your specific electrical system requirements to prevent nuisance tripping or inadequate protection.
  • Monitorització energètica: Utilize the app's energy statistics to track daily, monthly, and yearly consumption. This can help identify energy usage patterns and potential savings.

10. Solució De Problemes

Taula 3: Passos habituals per a la resolució de problemes
ProblemaCausa possibleSolució
Wi-Fi function not working / Device won't connect to appIncorrect Wi-Fi credentials, 5GHz network, device not in pairing mode, weak signal.Ensure your Wi-Fi is 2.4GHz. Verify Wi-Fi password. Put the device into pairing mode (refer to app instructions for specific steps). Check Wi-Fi signal strength near the device.
El dispositiu no s'encénNo power supply, incorrect wiring, internal fault.Check main power supply. Verify wiring connections according to diagrams. If power is present and wiring is correct, contact support.
Incorrect energy readingsCT clamp installed incorrectly (reversed direction), faulty CT clamp, incorrect multiplier settings in app.Check CT clamp direction (arrow should point towards load). Ensure CT clamps are securely closed. Verify voltage and current multiplier settings in the app.
Protection (e.g., over-voltage) not triggeringProtection function disabled, threshold set too high/low, no shunt trip release connected.Enable the specific protection function in the app or via device buttons. Adjust the threshold to an appropriate value. Ensure a compatible shunt trip release is correctly wired if using protector features.
Device frequently trips/shuts offProtection thresholds set too sensitively, actual load exceeding limits.Review and adjust protection thresholds (e.g., over current, over voltage) to prevent nuisance tripping. Check actual load to ensure it's within the device's and CT's rated capacity.

11. Manteniment

  • Mantingueu el dispositiu net i lliure de pols i humitat.
  • Comproveu periòdicament totes les connexions del cablejat per comprovar si estan ben ajustades i si hi ha signes de desgast o danys.
  • Assegureu-vos que hi hagi una ventilació adequada al voltant del dispositiu per evitar el sobreescalfament.
  • Revisa l'aplicació regularment per obtenir actualitzacions de firmware per garantir un rendiment i una seguretat òptims.

12. Garantia i Suport

This EARU energy meter comes with a 1-year warranty from the date of purchase. For technical support, warranty claims, or any questions not covered in this manual, please contact your retailer or the EARU Official Store directly. Please have your product model number (EASEM-G-TY-W) and purchase details ready when contacting support.

Documents relacionats - EASEM-G-TY-W

Preview Earu EAMPManual d'usuari del protector d'energia intel·ligent WiFi de la sèrie DW-TY-63
Manual d'usuari i especificacions tècniques de l'Earu EAMPProtector d'energia intel·ligent WiFi sèrie DW-TY-63, que detalla la instal·lació, la connexió de l'aplicació, la configuració dels paràmetres i les funcions de seguretat.
Preview EARU EAMPManual d'usuari del protector d'energia intel·ligent WiFi de la sèrie DW-TY-63 | Vol.tage, Corrent, Protecció contra fuites
Manual d'usuari complet per a l'EARU EAMPProtector d'energia intel·ligent WiFi sèrie DW-TY-63. Més informació sobre la instal·lació, les característiques, les especificacions tècniques, el control de l'aplicació i la resolució de problemes per a vol.tagprotecció contra e, corrent i fuites.
Preview EARU EAMPManual d'usuari del protector d'energia intel·ligent WiFi de la sèrie DW-TY-63
Manual d'usuari complet per a l'EARU EAMPDW-TY-63 series WiFi Smart Energy Protector, detailing features, installation, app connection, parameter settings, and troubleshooting. Covers over/under voltage, over current, leakage protection, energy monitoring, and remote control.
Preview EARU EAPDX-40/63 Series Adjustable VoltagManual d'usuari del protector de corrent i electròniques
User manual for the EARU EAPDX-40/63 Series Adjustable Voltage & Current Protector, detailing specifications, features, and operation for electrical protection. Includes setup instructions and parameter configuration.
Preview PC321-Z-TY Cl d'alimentació monofàsica/trifàsicaamp Guia d'inici ràpid
Get started with the EARU PC321-Z-TY Smart Power Clamp. This guide covers installation, configuration, and features for monitoring single/3-phase electricity usage with ZigBee connectivity and the Smart Life app.
Preview EARU D52-2066 Series Single Phase Multi-functional Energy Meter | Technical Specifications
Detailed technical specifications and wiring instructions for the EARU D52-2066 Series DIN-rail single-phase multi-functional energy meter, measuring AC voltage, current, active power, power factor, frequency, and electric energy.