SMART SENSOR AS816

SMART SENSOR AS816 Digital Anemometer Instruction Manual

Model: AS816

1. Introducció

The SMART SENSOR AS816 Digital Anemometer is a compact, high-precision instrument designed for measuring air flow and wind speed, along with environmental temperature. Its portable design allows for easy carrying and testing in various environments. It features a high-precision wind speed sensor, fast response, and stable performance across a temperature range of 0℃ to 50℃.

This device is a perfect tool for measuring wind speed in diverse applications such as power generation, steel production, petrochemical industries, energy saving assessments, ventilation systems, meteorology, sports activities, home testing, scientific research, wind tunnel testing, fan manufacturing, and exhaust systems.

Illustration of various applications for the AS816 Digital Anemometer, including HVAC, wind power, and environmental monitoring.

Figure 1: Diverse applications of the AS816 Digital Anemometer.

2. Informació de seguretat

Please read and understand all safety information before operating this device. Failure to follow these instructions may result in injury or damage to the instrument.

  • No intenteu desmuntar o modificar l'instrument.
  • Mantingueu el dispositiu allunyat de l'aigua i d'ambients amb molta humitat.
  • Eviteu exposar el dispositiu a temperatures extremes o a la llum solar directa durant períodes prolongats.
  • Ensure batteries are inserted with correct polarity. Remove batteries if the device will not be used for an extended period to prevent leakage.
  • Handle the rotating fan (impeller) with care to avoid damage.

3. Contingut del paquet

En desempaquetar, comproveu que tots els elements que s'enumeren a continuació hi són presents i en bon estat:

  • 1 x SMART SENSOR AS816 Digital Anemometer
  • 1 x manual d'instruccions
SMART SENSOR AS816 Digital Anemometer in retail packaging.

Figure 2: AS816 Digital Anemometer in its retail packaging.

4. Producte acabatview

Familiarize yourself with the components and controls of your AS816 Digital Anemometer:

Diagram illustrating the components and display elements of the AS816 Digital Anemometer.

Figure 3: Labeled diagram of the AS816 Digital Anemometer.

  1. Magnetic Suspension Rotating Shaft: Ensures smooth and accurate rotation of the impeller.
  2. High Strength Ultra Light 5-Leaf Impeller: Designed for sensitive and accurate wind speed detection.
  3. Air Temperature Sensor: Mesura la temperatura ambient.
  4. Indicador de llum de fons: Illuminates the display for visibility in low light.
  5. Electric Quantity Index (Battery Indicator): Mostra la durada restant de la bateria.
  6. Pantalla d'alta definició: Digital screen showing wind speed and temperature readings.
  7. Temperatura del vent: Displays the measured air temperature.
  8. Wind Speed Value: Displays the measured wind speed.
  9. Wind Speed Unit (m/s, Ft/min, Knots, km/h, Mph): Indicates the current unit of wind speed measurement.
  10. Wind Temperature Unit (°C/°F): Indicates the current unit of temperature measurement.
  11. High Strength Ductile Engineering Housing: C duradorasing per a protecció.
  12. Interruptor (botó d'engegada): Encén i apaga el dispositiu.
  13. Multifunction Key (Mode): Cycles through different measurement modes (e.g., Max/Min, Average, Current, Data Retention).
  14. Wind Speed Unit Selection Key (Unit): Changes the unit for wind speed measurement.
  15. Wind Temperature Celsius/Fahrenheit Key (°C/°F): Toggles between Celsius and Fahrenheit for temperature display.
  16. Control de la llum de fons: Press and hold the °C/°F button for 2 seconds to control the backlight.

5. Especificacions

CaracterísticaEspecificació
ModelAS816
Interval de mesura de la velocitat del vent0.3~30 m/s
Wind Speed Measurement Error± 5% + 0.1 dgt
Wind Speed Unit Selectionm/s, Ft/min, Knots, km/h, Mph
Maximum/Minimum Measurement
Probe Rotation180 graus
Wind Temperature Measurement Range0-50 ℃
Error de temperatura± 2 ℃
°C/°F Unit Conversion
Pantalla de llum de fons
Monitorització de potència
Indicador de bateria baixa
Resolució0.1 m/s
Data Retention Function
Funció d'apagat automàtic
Temps d'apagat automàtic14 minuts sense operació
Font d'alimentació3 piles AAA de 1.5 V (no incloses)
Pes net del producte80 g
Mida del producte162 x 47 x 25 mm (6.37 x 1.85 x 0.98 polzades)
Detailed specifications table for the AS816 Digital Anemometer.

Figure 4: Specifications table for the AS816 Digital Anemometer.

6. Configuració

6.1 Instal·lació de la bateria

The AS816 Digital Anemometer requires three (3) 1.5V AAA batteries (not included) for operation.

  1. Localitzeu la tapa del compartiment de la bateria a la part posterior del dispositiu.
  2. Feu lliscar la tapa cap avall o en la direcció indicada per una fletxa per obrir-la.
  3. Insert three AAA batteries, ensuring correct polarity (+ and - terminals match the markings inside the compartment).
  4. Tanqueu bé la tapa del compartiment de la bateria.
posterior view of the AS816 Digital Anemometer with open battery compartment and AAA batteries.

Figura 5: Compartiment de piles amb piles AAA.

7. Instruccions de funcionament

7.1 Encès/Apagat

  • Premeu el botó Canvia button (power symbol) to turn the anemometer ON.
  • Manteniu premut el botó Canvia button again to turn the anemometer OFF.
  • The device will automatically shut down after 14 minutes of no operation to conserve battery life.

7.2 Mesura de la velocitat del vent

Once powered on, the device will immediately begin measuring wind speed. Ensure the impeller is exposed to the airflow you wish to measure.

  • The probe can be rotated 180 degrees to position the impeller correctly relative to the wind direction.
  • The current wind speed will be displayed on the main screen.

7.3 Selecció d'unitats

  • Premeu el botó Unitat button to cycle through the available wind speed units: m/s, Ft/min, Knots, km/h, Mph.
  • The selected unit will be displayed next to the wind speed reading.

7.4 Temperature Measurement and Unit Conversion

  • The ambient temperature will be displayed below the wind speed reading.
  • Premeu el botó ° C / ° F button to toggle between Celsius (°C) and Fahrenheit (°F) temperature units.

7.5 Measurement Modes (Max/Min/Average/Current)

  • Premeu el botó Mode button to cycle through different measurement modes.
  • Available modes typically include:
    • Actual: Displays the real-time wind speed.
    • MÀXIM: Displays the maximum wind speed recorded since the device was powered on or reset.
    • MIN: Displays the minimum wind speed recorded since the device was powered on or reset.
    • AVG (Average): Displays the average wind speed over a period.
  • Refer to the display indicators to identify the active mode.

7.6 Data Retention (HOLD Function)

  • While in a measurement mode, press the Mode button briefly to activate the Data Retention (HOLD) function. This will freeze the current reading on the display.
  • Premeu el botó Mode button again to exit the HOLD function and resume live measurement.

Control de retroiluminació 7.7

  • To turn the backlight ON or OFF, press and hold the ° C / ° F botó durant aproximadament 2 segons.
  • The backlight enhances visibility in dimly lit conditions.

8. Manteniment

8.1 Neteja

  • Netegeu el dispositiu amb un drap suau i sec.
  • Do not use abrasive cleaners, solvents, or strong chemicals, as these may damage the casing o pantalla.
  • Keep the impeller free from dust and debris to ensure accurate readings. Use a soft brush or compressed air if necessary, being careful not to damage the blades.

8.2 Substitució de la bateria

  • When the low battery indicator appears on the display, replace all three AAA batteries promptly.
  • Seguiu els passos d'instal·lació de la bateria de la secció 6.1.
  • Elimineu les piles velles d'acord amb la normativa local.

8.3 Emmagatzematge

  • Si guardeu el dispositiu durant un període prolongat, traieu-ne les piles per evitar fuites.
  • Emmagatzemar en un lloc fresc i sec, allunyat de la llum solar directa i de temperatures extremes.

9. Solució De Problemes

ProblemaCausa possibleSolució
El dispositiu no s'encénBateries gastades o mal instal·ladesComproveu la polaritat de la bateria; substituïu-la per piles AAA noves.
Inaccurate wind speed readingsImpeller obstructed or damaged; device not positioned correctly in airflowEnsure impeller is clean and rotates freely. Position the anemometer directly into the airflow.
La pantalla és tènue o no es veuBacklight off; low batteryActivate backlight (hold °C/°F button for 2s). Replace batteries if low battery indicator is on.
Automatic shutdown occurs too quicklyNormal operation (14 minutes inactivity)This is a power-saving feature. Press any button to reactivate.

10. Consells d'usuari

  • For the most accurate wind speed readings, ensure the anemometer's impeller is facing directly into the wind source.
  • When measuring temperature, allow a few moments for the sensor to stabilize and reflect the ambient conditions accurately.
  • Utilize the Max/Min modes to capture peak gusts or lowest wind speeds over a measurement period, which can be useful for various applications.
  • The compact size makes it ideal for quick spot checks in hard-to-reach areas or for carrying in a toolkit.

11. Garantia i Suport

This product is designed for reliability and performance. For any questions, technical support, or warranty inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase for warranty claims.

Documents relacionats - AS816

Preview Manual d'instruccions de l'anemòmetre SMART SENSOR AR816
Comprehensive instruction manual for the SMART SENSOR AR816 Anemometer, detailing its functions, operation, and technical specifications for wind speed and temperature measurement.
Preview SMART SENSOR AS823 Digital Lux Meter Instruction Manual
Instruction manual for the SMART SENSOR AS823 Digital Lux Meter, covering features, operations, specifications, and a detailed diagram description for accurate light measurement.
Preview AR824 Digital Sound Level Meter Operation Manual
Operation manual for the AR824 Digital Sound Level Meter by SMART SENSOR. Covers features, specifications, calibration, operation, and cautions for accurate sound measurement.
Preview SMART SENSOR AR8100 Oxygen Detector Instruction Manual
Instruction manual for the SMART SENSOR AR8100 portable oxygen detector. Learn how to operate, calibrate, and understand readings for accurate oxygen level measurement in various environments.
Preview Smart Sensor Precision Measurement Instruments: Thickness & Pressure Gauges
Discover the Smart Sensor range of precision measurement tools, including ultrasonic thickness gauges (AS840, AS850, AS860, AR850, AR860), film/coating thickness gauges (AS930, AS931, AR930, AR931, AR932), and differential pressure meters (AS510). Distributed by Neonics Co., Ltd.
Preview Smart Sensor ST9604 Digital Sound Level Meter - Technical Data Sheet by ICHEMING
Comprehensive technical data sheet for the Smart Sensor ST9604 Digital Sound Level Meter, featuring measurement ranges, accuracy, specifications, and features. Distributed by ICHEMING.