1. Introducció
The ZOYI ZT-XR1 is a versatile 2-in-1 high-precision digital multimeter and internal resistance tester. It is designed for accurate electrical measurements and comprehensive battery analysis, making it an essential tool for professionals and hobbyists in various fields including equipment maintenance, automotive repair, production testing, electronic engineering, and scientific research.
This device features a 4.5-digit display, True RMS measurement, auto-ranging capabilities, and supports 4-wire measurement for highly accurate internal resistance testing of a wide range of battery types.

Figure 1: ZOYI ZT-XR1 Multimeter Overview
2. Informació de seguretat
Please read and understand all safety information before operating this device. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Always ensure the device is in the correct measurement mode and range before connecting test leads.
- No aplicar voltage or current that exceeds the maximum rated values for the selected range.
- Aneu amb extrema precaució quan treballeu amb voltagper sobre de 30 V CA RMS, 42 V pic o 60 V CC. Aquests voltagsuposen un risc de xoc.
- Inspect test leads for damaged insulation or exposed metal before use. Replace damaged leads immediately.
- Do not operate the device if it appears damaged or if the case is open.
- Assegureu-vos que el compartiment de la bateria estigui ben tancat abans de fer-lo funcionar.
- This device is rated CAT III 600V and CAT II 1000V. Do not use it in environments exceeding these ratings.
3. Producte acabatview
3.1. Components

Figure 2: ZOYI ZT-XR1 and Included Accessories
The ZOYI ZT-XR1 package typically includes:
- ZOYI ZT-XR1 Multimeter
- Standard Test Leads (Red and Black)
- Kelvin Clips (for 4-wire internal resistance measurement)
- Cable de càrrega USB tipus C
- Bossa de transport
- Temperature Probe (K-type, for temperature measurement models)
3.2. Device Layout and Functions

Figure 3: ZT-XR1 Front Panel and Function Icons
The ZT-XR1 features a 2.4-inch IPS HD Color Display and intuitive button controls:
- Botó d'encesa: Turns the device ON/OFF. Press and hold for >2 seconds for power off.
- BATT DMM Button: Switches between Battery Internal Resistance Test mode and Digital Multimeter (DMM) mode.
- Hz/V/mV Button: Selects Frequency, AC/DC Voltage, or mV measurement.
- Ohm/Capacitance/Diode/Continuity Button: Cycles through Resistance, Capacitance, Diode Test, and Continuity modes.
- Range/Speed/REC Button: Manually selects measurement range (in manual mode), adjusts measurement speed, or activates data recording.
- OK/MENU Button: Confirma les seleccions o accedeix al menú.
- HOLD/>2S ZERO Button: Holds the current reading on the display. Press and hold for >2 seconds to perform quick zeroing (REL function).
- Botó ESBORRA: Clears data or settings.
- Preses d'entrada: Dedicated jacks for test leads and Kelvin clips (BATT, COM, VΩHz, DC100V MAX).
4. Configuració
4.1. Instal·lació i càrrega de la bateria
The ZT-XR1 is powered by an internal 2000mAh lithium battery. It comes with a battery included.
- Assegureu-vos que el dispositiu estigui apagat.
- Localitzeu el compartiment de la bateria a la part posterior del dispositiu.
- Insert the 18650 battery if not already installed, observing correct polarity.
- To charge, connect the included USB Type-C cable to the device's charging port and a 5V/1A USB power adapter. The battery indicator on the display will show charging status.

Figura 4: Inserció de la bateria
4.2. Connexió dels cables de prova
Always connect the common (COM) test lead first, then the live (positive) test lead.
- For Multimeter Functions (Voltage, Resistance, Capacitance, Diode, Frequency, Continuity):
- Insert the black test lead into the 'COM' jack.
- Insert the red test lead into the 'VΩHz' jack.
- For Battery Internal Resistance Testing (4-Wire Measurement):
- Connect the Kelvin clips to the dedicated 'BATT' and 'COM' ports. Ensure proper connection for accurate 4-wire measurement.

Figure 5: Connecting Test Leads for Voltage Mesura
5. Funcionament
5.1. Encendre/apagar
Press the red power button once to turn on the device. To turn off, press and hold the power button for more than 2 seconds. The device also features an Auto Power-Off function to conserve battery life.
5.2. Digital Multimeter (DMM) Functions
In DMM mode, the ZT-XR1 supports a wide range of measurements:
- Volum AC / DCtage: Connect test leads to 'COM' and 'VΩHz' jacks. Use the 'Hz/V/mV' button to select AC or DC voltage. The device features auto-ranging.
- Resistència: Connect test leads to 'COM' and 'VΩHz' jacks. Use the Ohm/Capacitance/Diode/Continuity button to select resistance measurement.
- Capacitat: Connect test leads to 'COM' and 'VΩHz' jacks. Use the Ohm/Capacitance/Diode/Continuity button to select capacitance measurement.
- Prova de díode: Connect test leads to 'COM' and 'VΩHz' jacks. Use the Ohm/Capacitance/Diode/Continuity button to select diode test.
- Continuïtat: Connect test leads to 'COM' and 'VΩHz' jacks. Use the Ohm/Capacitance/Diode/Continuity button to select continuity test. An audible beep indicates continuity.
- Freqüència: Connect test leads to 'COM' and 'VΩHz' jacks. Use the 'Hz/V/mV' button to select frequency measurement.
- Temperatura: Connect a K-type temperature probe to the appropriate jacks (refer to the device's port labels). The device supports temperature measurement from -20°C to 1000°C (-4°F to 1832°F).

Figura 6: Mesura de la temperatura
5.3. Battery Internal Resistance Testing
The ZT-XR1 excels at internal resistance testing using a true 4-wire (Kelvin) measurement method with a 1KHz sine wave, providing milliohm-level accuracy.
- Press the 'BATT DMM' button to switch to Battery Internal Resistance Test mode.
- Connect the Kelvin clips to the battery terminals, ensuring good contact. The red clip typically connects to the positive terminal, and the black clip to the negative terminal.
- The display will show the battery's voltage i resistència interna.
- The device supports testing various battery types, including Button Cells, Alkaline Batteries, Carbon Batteries, Lithium Polymer Batteries, Lithium-Ion Batteries, and Lead-Acid Batteries.

Figure 7: Battery Internal Resistance Measurement

Figure 8: Supported Battery Types for Internal Resistance Testing
5.4. Funcions avançades
- RMS veritable: Provides accurate measurements for non-sinusoidal AC waveforms.
- Rang automàtic: Automatically selects the appropriate measurement range for convenience.
- Quick Zeroing (REL): Press and hold the 'HOLD/>2S ZERO' button to activate the relative measurement function, useful for nulling out lead resistance or comparing measurements.
- Data Recording/Export: The device supports recording measurement trends and data export (details on export method may vary, refer to on-screen menu or additional software if provided).
- Battery Sorting Function: Aids in categorizing batteries based on their internal resistance and voltage característiques.
Video 1: ZOYI ZT-XR1 Multimeter Features Overview. This video highlights the 4.5-digit display, 2-in-1 multimeter and battery internal resistance tester, universal battery compatibility, milliohm-level accuracy, true 4-wire (Kelvin) measurement with 1KHz sine wave testing, comprehensive measurement functions, measurement trend display, data export, dual-injection molding process, robust and durable design, lightweight and portable ergonomic contour design, and 2.4-inch IPS HD color display with CAT III 600V / CAT II 1000V safety ratings.
6. Manteniment
6.1. Neteja
Netegeu el dispositiu amb un suau, damp drap. No utilitzeu productes de neteja abrasius ni dissolvents. Assegureu-vos que el dispositiu estigui apagat i desconnectat de qualsevol circuit abans de netejar-lo.
6.2. Cura de la bateria
The internal 2000mAh lithium battery provides up to 12 hours of operation. Recharge the battery using the provided USB Type-C cable and a 5V/1A adapter when the battery indicator is low. For long-term storage, charge the battery to approximately 50% and store the device in a cool, dry place.
6.3. Emmagatzematge
When not in use, store the ZT-XR1 in its carrying pouch in a dry, dust-free environment away from direct sunlight and extreme temperatures.
7. Solució De Problemes
- El dispositiu no s'encén: Check if the battery is charged. Ensure the battery is correctly installed.
- Lectures inexactes: Verify that the test leads are properly connected and not damaged. Ensure the correct measurement mode and range are selected. For internal resistance, confirm Kelvin clips are making good contact.
- Sense pantalla: Check battery charge. If the display is blank or shows error codes, refer to the full manual for specific error interpretations.
- Auto Power-Off activates too quickly: Check the auto power-off settings in the device menu and adjust if necessary.
8. Especificacions

Figura 9: Especificacions tècniques detallades
| Paràmetre | Valor |
|---|---|
| Nom de marca | ZOYI |
| Model | ZT-XR1 |
| Tipus de visualització | Digital Display (2.4-inch Color Display) |
| Mode de funcionament | Rang automàtic |
| Temperatura de funcionament | 0 - 40 ℃ |
| Subministraments de bricolatge | Elèctric |
| Certificació | CE |
| Origen | Xina continental |
| Bateria inclosa | Sí |
| Tipus de bateria | Bateria de liti de 2000 mAh |
| Carregant | TIPUS-C (5V/1A) |
| DC Voltage | 2.5000V/25.000V/250.00V/1000.0V |
| Vol. ACtage | 2.5000V/25.000V/250.00V/750.0V |
| Rang de mesura de resistència | 250.00Ω/2.5000kΩ/25.000kΩ/250.00kΩ/2.5000MΩ/25.00MΩ/250.0MΩ |
| Rang de mesura de capacitança | 9.999nF/99.99nF/999.9nF/9.999μF/99.99μF/999.9μF/9.999mF/99.99mF |
| Internal Resistance (Battery) | Voltage range: ±100V, Resistance range: 0.1mΩ~200Ω, Resistance Accuracy: 0.2%, Voltage Accuracy: 0.5% |
| Freqüència | 999.9KHz/99.99KHz/9.999KHz/999.9Hz/99.99Hz |
| Díode | Sí |
| Continuïtat | Sí |
| Funcions | Digital Multimeter, Battery Internal Resistance Tester |
| Llengua | xinès, anglès |
| Actualització del firmware | Sí |
| Dimensions | 149 * 76 * 33.5 mm |
| Pes | 193 g |
9. Consells d'usuari
- For the most accurate internal resistance measurements, always use the dedicated 4-wire Kelvin clips.
- When measuring low resistance values, use the REL (Quick Zeroing) function to compensate for test lead resistance.
- Keep the display clean for optimal readability, especially in varying light conditions.
- Utilize the data recording feature for logging measurements over time, which can be helpful for diagnostics and trend analysis.
10. Garantia i Suport