TDA-08 Series TDA-08 Series

TDA-08 Rail Type Weighing Force Transmitter Weight Sensor Signal Amplifier Analog User Manual

Model: TDA-08 Series (TDA-08A, TDA-08B, TDA-08C)

1. Producte acabatview

The TDA-08 series is a versatile rail-type weighing force transmitter and weight sensor signal amplifier designed for industrial applications. It integrates force measurement, weighing, display, and control functions into a single compact unit. This device is suitable for various weighing and force measurement systems, providing accurate signal amplification and processing.

Three models of TDA-08 series weighing force transmitters (TDA-08A, TDA-08B, TDA-08C) with digital displays and terminal blocks.
Figure 1: TDA-08 Series Weighing Force Transmitters (TDA-08A, TDA-08B, TDA-08C)

Característiques clau

  • Integrates force measurement, weighing, display, and control functions.
  • Internal integrated switching power supply, operating voltagRang e: de 10 V a 30 V.
  • Equipped with an analog filtering function for stable readings.
  • Automatic error diagnosis for easy identification and resolution of issues.
  • Features automatic zero tracking.
  • Supports automatic zeroing upon power-up.
  • Configurable zero range and filter intensity.

2. Informació de seguretat

Please read and understand all safety instructions before installation, operation, or maintenance of the TDA-08 series device. Failure to follow these instructions may result in injury or damage to the equipment.

  • Assegureu-vos que la font d'alimentació voltage is within the specified range (10V-30V DC).
  • All wiring should be performed by qualified personnel and in accordance with local electrical codes.
  • Desconnecteu l'alimentació abans de fer qualsevol connexió o realitzar tasques de manteniment.
  • Avoid exposing the device to excessive moisture, dust, or extreme temperatures.
  • Do not open the device enclosure unless specifically instructed to do so by a qualified technician.

3. Instal·lació i configuració

3.1 Desembalatge

Carefully remove the TDA-08 unit from its packaging. Inspect the device for any signs of physical damage. Retain the packaging for future transport or storage.

3.2 Muntatge

The TDA-08 series is designed for rail mounting. Securely attach the device to a standard DIN rail in a suitable enclosure, ensuring adequate ventilation and protection from environmental factors.

Outline dimension diagram of the TDA-08 series device, showing length, height, and depth for rail mounting.
Figure 2: TDA-08 Series Outline Dimensions (88mm x 53mm x 59mm)

3.3 Cablejat

Refer to the terminal block labels on your specific TDA-08 model (TDA-08A, TDA-08B, or TDA-08C) for correct connections. Typical connections include:

  • Entrada d'alimentació: Connect 10V-30V DC power to the designated power terminals (e.g., +V, -V, GND).
  • Load Cell/Sensor Input: Connect the load cell or weight sensor to the input terminals (e.g., E+, E-, S+, S-). Ensure correct polarity.
  • Sortida analògica: Connect to external control systems or displays via analog output terminals (e.g., OUT, AO).
  • Digital Inputs/Outputs: If applicable, connect control signals to digital input (e.g., IN) and output (e.g., OUT1, OUT2, OUT3) terminals.

Always consult the detailed wiring diagram specific to your TDA-08 model and application. If unsure, seek assistance from a qualified electrician or system integrator.

3.4 Engegada inicial

After all connections are securely made, apply power to the device. The display should illuminate, and the device may perform an automatic zeroing sequence. Observe the display for any error messages or unexpected behavior.

4. Funcionament

The TDA-08 series features a digital display and control buttons for easy operation. Specific button functions may vary slightly between models (TDA-08A, TDA-08B, TDA-08C).

4.1 Mostra finalview

The digital display shows the current measured value (e.g., weight, force). Indicators (e.g., NET, PWAK, Kg, g, N, KN) provide additional status information.

4.2 Basic Weighing/Measurement

Once powered on and calibrated, the device will continuously display the measured value from the connected sensor. Place the item to be weighed or apply force to the sensor.

4.3 Reducció a zero

To set the current reading to zero (e.g., to tare a container), press the ZERO button. The device supports automatic zero tracking and power-up zeroing.

4.4 Calibració

Calibration is crucial for accurate measurements. To enter calibration mode, typically press and hold the SET/CALI button. Follow the on-screen prompts to perform a multi-point calibration using known weights or force standards. Refer to the specific model's detailed instructions for the exact calibration procedure.

4.5 Configuració de paràmetres

The device allows configuration of various parameters such as zero range, filter intensity, and output settings. Access the settings menu by pressing the SET/CALI button (or similar, depending on model). Use the navigation buttons (e.g., UP/DOWN arrows, SWITCH, OFTEN) to adjust values and confirm selections.

5. Manteniment

The TDA-08 series is designed for reliable operation with minimal maintenance. Follow these guidelines to ensure longevity and performance:

  • Neteja: Keep the device clean and free from dust and debris. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents.
  • Inspecció: Periodically inspect all wiring connections for tightness and signs of wear or corrosion.
  • Medi ambient: Assegureu-vos que l'entorn de funcionament es mantingui dins dels rangs de temperatura i humitat especificats.
  • Recalibració: Recalibrate the device periodically or if you suspect measurement inaccuracies.

6. Solució De Problemes

The TDA-08 series includes automatic error diagnosis to help identify and resolve common issues. If you encounter a problem, refer to the table below:

ProblemaCausa possibleSolució
La pantalla està en blancSense potència o vol incorrectetage.Comproveu les connexions de la font d'alimentació i el volumtage (10V-30V CC).
Lectures inexactesNeeds calibration; sensor issue; environmental interference.Perform calibration. Check sensor wiring and integrity. Ensure stable operating environment.
Display shows "OVER" or "UNDER"Sensor overload/underload; incorrect range setting.Ensure load is within sensor capacity. Check and adjust range settings if configurable.
Cap resposta dels botonsDevice frozen; button malfunction.Power cycle the device. If problem persists, contact support.
Lectures inestablesElectrical noise; mechanical vibration; filter intensity too low.Check for sources of electrical interference. Reduce vibrations. Increase filter intensity in settings.

7. Especificacions

CaracterísticaEspecificació
ModelTDA-08 Series (TDA-08A, TDA-08B, TDA-08C)
Tipus FixMagnetic Fastener (for mounting)
ÚsWindow (likely refers to display window)
Vol. Operatiutage10 V ~ 30 V CC
Filtering FunctionFiltrat analògic
Diagnòstic d'errorsAutomàtic
Seguiment zeroAutomàtic
Power-up ZeroingAutomàtic
Paràmetres configurablesZero range, filter intensity, etc.
OrigenXina continental

Dimensions i pes

  • Device Dimensions (L x H x D): 88mm x 53mm x 59mm (including rail mount)
  • Dimensions del paquet (L x A x A): 23 cm x 11 cm x 7 cm
  • Pes del paquet: 0.8 kg

8. Consells d'usuari

While specific user tips from reviews or Q&A are not available, here are some general recommendations for optimal use:

  • For critical applications, always verify calibration regularly.
  • If experiencing signal noise, ensure proper grounding of the system and use shielded cables for sensor connections.
  • Keep a record of your calibration dates and any parameter changes.

9. Garantia i Suport

For warranty information, technical support, or service inquiries, please contact your vendor or the manufacturer directly. Ensure you have your product model and serial number (if applicable) ready when contacting support.

Documents relacionats - TDA-08 Series

Preview Llibre de dades de circuits integrats de Siemens per a electrònica d'entreteniment 1980/81
Llibre de dades complet de Siemens de 1980/81 que detalla els circuits integrats (CI) per a electrònica d'entreteniment, incloent-hi aplicacions en televisió, radiodifusió i usos generals. Inclou especificacions del producte, nomenclatura i informació sobre l'embalatge.
Preview Procediments de canvi d'hora per a sistemes telefònics empresarials
Guia completa que detalla com canviar l'hora i la data en diversos sistemes telefònics empresarials, inclosos els models Vertical/Comdial, Siemens i Panasonic. Seguiu les instruccions pas a pas per a una sincronització horària precisa.
Preview Alpine TDA-7572R/TDA-7570R Service Manual - Technical Guide
Comprehensive service manual for Alpine TDA-7572R and TDA-7570R FM/MW/LW/RDS Cassette Receivers with CD Shuttle Control. Includes specifications, adjustment procedures, schematics, and parts diagrams.
Preview Sèrie TDA Digital Avançada de Tecnare AmpManual d'operació del lifier
Aquest manual d'instruccions proporciona instruccions detallades per al dispositiu Tecnare TDA Series Digital Advanced. Amplificadors, que cobreixen la instal·lació, les característiques i les precaucions de seguretat.
Preview Bosch TDA 23 Dampfbügeleisen Bedienungsanleitung
Umfassende Bedienungsanleitung für das Bosch TDA 23 Dampfbügeleisen, einschließlich Sicherheitshinweisen, Gebrauchsanweisungen, Reinigungs- und Wartungstipps sowie Informationen zu zusätzlichen Funktionen.
Preview Manual d'instruccions de la barrena de terra de gasolina BILT HARD
Manual d'instruccions per a la perforadora de terra de gasolina BILT HARD, SKU: TDA-0651. Inclou mesures de seguretat importants, precaucions d'instal·lació, instruccions d'ús, pautes de manteniment i informació sobre la garantia.