GEYA GSW6 Series Floor Heating Thermostat

GEYA GSW6 Series Floor Heating Thermostat

Manual d'instruccions

1. Producte acabatview

The GEYA GSW6 Series Floor Heating Thermostat is an intelligent timing device designed for precise temperature control in floor heating systems. It features an LCD screen for clear display and is suitable for both hydraulic (water heating/gas boiler) and high-power electric heating applications.

Funcions clau:

  • Control precís de la temperatura
  • Specialized for engineering applications
  • Hydraulic and electric heating linkage
  • High-power electric heating capability
GEYA Floor Heating Thermostat with key functions listed
Figure 1: Product Functions Overview

2. Instal·lació i configuració

Before installation, ensure the power supply is disconnected to prevent electric shock. Installation should be performed by a qualified electrician.

2.1 Dimensions del producte

Diagram showing thermostat dimensions: 90mm height, 86mm width, 30mm depth for back unit, 42mm total depth, 50mm width for back unit.
Figure 2: Thermostat Dimensions and Components
lateral view of the thermostat showing 86mm width, 86mm height, 26mm total depth, and 14mm front depth.
Figura 3: Dimensions detallades del producte

2.2 Esquemes de cablejat

The thermostat supports different wiring configurations based on the heating type. Refer to the diagrams below for correct connections.

Wiring diagram for 3A (Gas Boiler, Water Heating) and 16A (Electric Heating with NTC sensor).
Figure 4: Wiring for 3A (Hydraulic) and 16A (Electric) Models
Wiring diagram for Water Heating/Gas Boiler (3A, excluding sensor line).
Figure 5: Wiring for Water Heating/Gas Boiler (3A)

Nota: For electric heating models (16A/25A), a 3-meter sensing cable is included. For plumbing models (3A), the sensor line is typically excluded and uses dry contact.

Back of thermostat showing wiring terminals for L, N, N1, L1, and NTC sensor connections.
Figura 6: posterior View amb terminals de cablejat

3. Instruccions de funcionament

The thermostat features an intuitive interface with clear display icons and easy-to-understand button operations.

A hand pressing a button on the thermostat, illustrating easy operation.
Figure 7: Easy Button Operation

3.1 Mostra les icones

Diagram explaining thermostat display icons: Time Display, Room Temperature, Heating Icon, Mode Icon, Lock Icon, Button Icon.
Figure 8: Description of Display Icons

3.2 User Operation Functions

  • Compensació de temperatura: Adjust the displayed temperature to match the actual room temperature.
  • Selecció del sensor: Choose between internal sensor, external sensor, or both (NTC Select).
  • Limit Temperature Setting: Define the upper limit for the temperature setting range (e.g., 35-90℃).
  • Inici de la diferència de temperatura: Set the hysteresis or differential temperature for heating activation.
  • Funció anticongelant: Activates heating if the temperature drops below a set minimum (e.g., 1℃) to prevent freezing.
  • Primary and Secondary Reverse Selection: Configure the output behavior for different heating systems.
  • Passive Output Delay Setting: Adjust the delay for passive output activation.
  • Set Temperature Upper Limit: Define the maximum allowable temperature for user settings.
  • Restore Original Mode: Reset the thermostat to its factory default settings.

3.3 Vídeo de demostració del producte

Video 1: GEYA Thermostat Operation Demonstration. This video shows how to power on the device, select modes, and navigate the display.

4. Manteniment

The GEYA GSW6 Series Floor Heating Thermostat is designed for reliable operation with minimal maintenance. To ensure longevity and optimal performance:

  • Keep the thermostat clean and free from dust. Use a soft, dry cloth for cleaning.
  • Avoid exposing the device to direct sunlight, extreme temperatures, or high humidity.
  • Do not use abrasive cleaners or solvents on the thermostat's surface.
  • Ensure all wiring connections remain secure. If any connections appear loose or damaged, consult a qualified electrician.

5. Solució De Problemes

Si teniu problemes amb el termòstat, tingueu en compte els passos bàsics següents per resoldre problemes:

  • Sense pantalla/alimentació: Check the power supply to the thermostat. Ensure circuit breakers are not tripped.
  • Lectura de temperatura incorrecta: Verify the sensor is correctly installed and connected. If an external sensor is used, ensure it is placed appropriately to measure the desired temperature. Consider using the temperature compensation function if a minor adjustment is needed.
  • La calefacció no s'activa: Check the set temperature to ensure it is above the current room temperature. Verify the heating mode is correctly selected. Inspect wiring connections for any disconnections (consult a professional if unsure).
  • El termòstat no respon: Try restarting the thermostat by cycling its power. If issues persist, consider performing a factory reset (refer to 'Restore Original Mode' in Operating Instructions).

For complex issues or if troubleshooting steps do not resolve the problem, please contact GEYA customer support or a certified technician.

6. Especificacions

Característica Especificació
Nom de marca GEYA
Número de model GSW6 Series Floor Heating Thermostats
Alimentació Voltage 95 V-240 V CA (50/60 Hz)
Potència consumida ≤0.02W (<1W)
Corrent de càrrega 3A (resistive water heating), 16A/25A (electric heating)
Sensor de temperatura NTC
Precisió de la temperatura ± 1 ℃
Interval de configuració de temperatura 5 ~ 60 ℃
Temperatura de l'entorn de treball -5 ~ 50 ℃
Mostra LCD
Interval de visualització 0 ~ 50 ℃
Material Anti-flammable PC
Certificació CE
Origen Xina continental

Models disponibles:

  • GSW6-K1RH3A: Plumbing model with hydraulic linkage (3A load current).
  • GSW6-K1H16A: Electric heating model (16A load current), includes 3-meter sensing cable.
  • GSW6-K1H25A: Electric heating model (25A load current), includes 3-meter sensing cable.

7. Consells d'usuari

Tot i que no hi ha cap usuari específicviews or Q&A were provided, general tips for floor heating thermostats include:

  • Col·locació òptima del sensor: Ensure the temperature sensor (if external) is placed in a location that accurately reflects the room's temperature, away from direct drafts or heat sources.
  • Gradual Adjustments: For floor heating, make temperature adjustments gradually. Floor heating systems have a slower response time compared to forced-air systems.
  • Mode d'estalvi d'energia: Utilize the ECO mode or programmable timing features to optimize energy consumption by setting lower temperatures during unoccupied periods.
  • Bloqueig per a nens: If available, activate the child lock feature to prevent accidental changes to settings.

8. Garantia i Suport

For warranty information, technical support, or service inquiries, please contact GEYA customer service through your purchase platform or the official GEYA website. Keep your purchase receipt and product model number handy for faster assistance.

Documents relacionats - GSW6 Series Floor Heating Thermostat

Preview GEYA TM07 Digital Timer Switch Instruction Manual
Detailed instructions and specifications for the GEYA TM07 digital timer switch, covering setup, programming, features like random function and countdown mode, and electrical parameters.
Preview GEYA GPS8-05 Voltage / Current Protector Instruction Manual
Instruction manual for the GEYA GPS8-05 Voltage / Current Protector, detailing its applications, features, technical specifications, parameter settings, wiring, and operational diagrams for household equipment protection.
Preview GEYA GRV8-UV Series Under Voltage Manual d'instruccions del relé
Instruction manual for GEYA GRV8-UV series under voltage relays, detailing applications, features, technical specifications, wiring diagrams, and dimensions for single and three-phase industrial and commercial systems.
Preview GEYA GRV8-SV LCD Display Voltage Manual d'instruccions del relé
Instruction manual for the GEYA GRV8-SV LCD display voltage relay, detailing its applications, features, technical parameters, wiring, operation, and parameter settings.
Preview GEYA GRI8-05 Current Monitoring Relay - Instruction Manual
Official instruction manual for the GEYA GRI8-05 series current monitoring relay. Provides details on applications, technical specifications, wiring diagrams, and installation guidelines.
Preview Manual del commutador de transferència automàtica dual de commutació ininterrompuda de mil·lisegons de Zhejiang Geya Electrical
Aquest manual proporciona informació detallada sobre el commutador de transferència automàtica dual de commutació ininterrompuda de mil·lisegons de Zhejiang Geya Electrical Co., Ltd., incloent-hi informació general, paràmetres tècnics, instal·lació, cablejat, manteniment i precaucions de seguretat.