1. Introducció
The TSUN MA06LS is an integrated magnetic grid ruler with a digital display meter, designed for high-precision measurement applications. This miniature electronic ruler provides accurate readings and is built for durability in various environments. This manual provides essential information for the proper installation, operation, maintenance, and troubleshooting of your MA06LS device.
2. Producte acabatview
2.1 Característiques clau
- Intelligent LCD backlight display for clear readings.
- Non-contact measurement principle, ensuring no wear and tear.
- High protection level, resistant to oil and dust.
- Icon-based shortcuts for common functions (modify current value, modify direction, sensor adaptive mode).
- Multi-function menu for parameter settings.
- Selectable linear measurement and angle measurement.
2.2 Components
The MA06LS system typically consists of the digital display meter, a read head, and a magnetic scale (magnetic tape).




3. Configuració i instal·lació
3.1 Magnetic Scale and Read Head Installation
The magnetic scale consists of three parts: a non-conductive magnetic strip, a non-magnetic steel strip, and a flexible magnetic strip. The total thickness is 1.8mm, width is 10mm, and length is supplied in rolls. The flexible magnetic strip (part A) needs to be attached to a clean, dry, and flat surface. A typical cleaning solution is 50% alcohol and 50% water mixture (please consult the manufacturer for similar solvents). Ensure no oxidation occurs on the surface when using on copper or steel.

3.2 Read Head Installation Instructions
- The distance between the read head and the magnetic scale should be controlled between 0.8mm and 1.0mm.
- When installing the read head, pay attention to the read head's marking and align it with the inductive magnetic scale according to the arrow direction.
- Refer to the attached diagram for read head installation angle deviation requirements.

3.3 Important Precautions
- The standard distance between the read head and the magnetic tape is 1mm.
- If the deviation during installation is too large, it will affect measurement accuracy and may even render the product unusable.
- The bending radius of the read head sensor cable must be greater than 25mm.
- The device should be installed more than 0.5 meters away from circuit breakers, relays, motor capacitors, brakes, pulse width modulators, and similar equipment to avoid interference.
- Cable routing must be separated from power lines to reduce noise interference.
4. Funcionament
4.1 Funcions dels botons

- P (F1) Button:
- Function/Confirm Key: Long press to enter parameter settings. Press again to select the parameter to modify.
- Up Arrow (F2) Button:
- Modify Key: Used to set and modify parameters.
- Premsa llarga (4S): Quick learning function for read head to magnetic strip distance error adjustment and calibration.
- Right Arrow (F3) Button:
- Tecla de canvi: Used for parameter switching and digit switching.
- Premsa llarga (4S): Modify the running direction (0 or 1).
- C (F4) Button:
- Tecla de sortida: Clear or exit the current mode.
- Premsa llarga (4S): Modify the current value (after modification, press the "P" key to exit).
4.2 Configuració dels paràmetres
The following table details the various parameters that can be configured on the MA06LS digital display meter:

| Paràmetre | Descripció de la funció | Interval/Opcions | Per defecte | Observacions |
|---|---|---|---|---|
| P01 | Current value setting (or quick key) | -99999 ~ 99999 | 0 | Saves input value as current value. After modification, press "P" to exit. |
| P02 | Measurement direction (or quick key) | 0 o 1 | 0 | 0 or 1 represents two directions. Can change sensor direction. |
| P03 | Self-adaptive calibration | GO | GO | Enters calibration state. Sensor moves slowly (or reverses) for about 10 seconds over 150mm. Completes learning and returns to current value. If calibration is incorrect, adjust sensor-magnetic scale distance to 1-2mm. |
| P10 | Interruptor d'unitat de mesura | 00: mm; 01: mm; 10: INCH; 11: INCH; 20: Angle; 21: Angle | 00 | Contrasenya: 1234 |
| P11 | Ratio coefficient | 0.00001 ~ 2.99999 | 1 | Display value = measured value * ratio coefficient. Password: 1234 |
| P12 | Concentric circle diameter | 0.01 ~ 999.99 | 500.00 | Diameter of the magnetic scale's attachment point. Add 1.5mm*2=3mm. |
| P13 | Resolució | 0.1, 0.05, 0.01, 1 | 0.1 | Length unit: mm. Angle unit: ". |
| P15 | Timed screen off | 0 o 1 | 0 | 0: Not enabled; 1: Screen off after 5 minutes. Password: 1234. Any key press wakes up. |
| P20 | Restaura la configuració de fàbrica | SURE? Yes/No | No | Restore factory settings. Password: 4321. |
| P21 | Test and debug preparation | SURE? Yes/No | No | Press "P" to confirm. Password: 5321. |
| P22 | Test and debug complete | SURE? Yes/No | No | Press "P" to confirm. Password: 5321. |
5. Manteniment
To ensure the longevity and accuracy of your TSUN MA06LS digital display meter, follow these maintenance guidelines:
- Keep the display and sensor clean. Use a soft, dry cloth for cleaning. For stubborn dirt on the magnetic scale, a 50% alcohol and 50% water mixture can be used, ensuring no residue remains.
- Avoid exposing the device to extreme temperatures, high humidity, or corrosive environments.
- Ensure all cable connections are secure and undamaged. Avoid sharp bends in the sensor cable (bending radius must be greater than 25mm).
- Regularly check the battery level and replace batteries promptly when the low battery indicator appears to prevent data loss.
6. Solució De Problemes
6.1 Codis d'error
The MA06LS display may show error codes to indicate specific issues:
| Codi d'error | Information/Cause |
|---|---|
| E01 | Error d'entrada |
| E02 | Falla del sensor |
| E03 | Danys al sensor |
| E04 | Magnetic scale failure |
| E05 | Magnetic scale damage |
| E06 | Read head too far from magnetic scale |
| E07 | Bateria voltage too low. Replace AA battery immediately. |
| E08 | Read head too close to magnetic scale |
| E09 | Read head too far from magnetic scale (duplicate of E06, possibly different threshold) |
| E10 | Read head too close to magnetic scale (duplicate of E08, possibly different threshold) |
| E20 | Sensor value exceeds display range |
6.2 Mostra informació
- Intelligent LCD Backlight Display: Proporciona una visibilitat clara en diverses condicions d'il·luminació.
- Indicador de bateria baixa: When this symbol appears, replace the AA battery immediately. Note: Replace batteries one by one to avoid data loss.
- Current Length Unit: The display shows the current length unit, typically in millimeters (mm).

7. Especificacions
Detailed technical specifications for the TSUN MA06LS digital display meter:
| Característica | Especificació |
|---|---|
| Precisió del sistema | ± (0.03 + 0.01*L) mm (L in meters) |
| Repetibilitat | Max. ± 0.01mm |
| Resolució | 0.01, 0.05, 0.1, 1 (selectable) |
| Interval de visualització | -99999 ~ 99999 |
| Consum actual | Max. 400uA |
| Bateria interna | Two AA batteries (super long standby) |
| Temperatura de treball | -20 ℃ ~ 70 ℃ |
| Max. External Dimensions | 73.7 mm × 36.2 mm × 29.56 mm |
| Mida d'obertura | 67.6mm × 32.1mm |
| Read Head Cable Length | Default 1M (customizable) |
| Read Head Gap | Standard 1mm ~ 2mm |
| Velocitat de moviment | Max. 5m/s |
| Matching Magnet | TR50/5mm+5mm |
8. Consells d'usuari
- For consistent and accurate readings, always ensure the magnetic scale and read head are clean and free from debris.
- When performing self-adaptive calibration (P03), ensure the sensor moves smoothly over the specified distance (150mm) for optimal results.
- If experiencing persistent errors related to read head distance (E06, E08, E09, E10), carefully re-check the physical gap and alignment as per installation instructions.
9. Suport
For any technical assistance, questions, or support regarding your TSUN MA06LS digital display meter, please contact the seller or manufacturer directly. Ensure you have your product model number (MA06LS) ready when seeking support.





