CERTEON Plastic Gear Flow Sensor

CERTEON Plastic Gear Flow Sensor Instruction Manual

Model: Plastic Gear Flow Sensor (Available in G1/4, G3/8, G1/2, G3/4 connection types)

Brand: CERTEON

1. Introducció

This CERTEON Plastic Gear Flow Sensor is designed for precise measurement of liquid flow in industrial and commercial systems. It utilizes a gear-driven mechanism combined with a Hall effect sensor to generate pulse output proportional to the flow rate. This durable and high-precision liquid gear meter is suitable for non-corrosive, low-viscosity liquids such as water, milk, oil, and detergents. It can be seamlessly integrated into various applications including washing machines, dishwashers, dosing systems, and liquid dispensing equipment.

Plastic Gear Flow Sensor with specifications overlay
Acabatview of the Plastic Gear Flow Sensor (Model OF05ZAT) with key specifications.

For a comprehensive guide and detailed documentation, please refer to the official user manual PDF: Manual d'usuari (PDF).

2. Especificacions

The following table details the technical specifications for the CERTEON Plastic Gear Flow Sensor:

Detailed specifications table for the flow sensor
Detailed specifications for various models of the flow sensor.
ParàmetreEspecificacióParàmetreEspecificació
Mida de la interfícieG1/4, G3/8, G1/2, G3/4MaterialPPS
Diàmetre interior/exteriorG3/8: 8mm/12.5mm, G1/2: 10mm/20.5mm, G3/4: 16mm/26mmVoltage RangDC3.5-24V
Durada del filG1/4: 10mm, G3/8 & G1/2: 29mm, G3/4: 18.7mmConsum actual≤10mA (DC5V)
Interval de fluxG1/4: 18-300 L/h, G3/8 & G1/2: 30-1200 L/h, G3/4: 30-3000 L/hPrecisió±1% (model dependent)
Frequency FormulaG1/4: F=(8.5 × Q) ±2%, G3/8 & G1/2: F=2.5 × Q, G3/4: F=1.2 × Q (F in Hz, Q in L/min)Unitat de pols0.54ML/P (G1/4)
Temperatura de funcionamentG1/4: -10°C to 70°C, Others: up to 80°CHumitat de funcionament35% -90% HR (sense condensació)
Pressió màximaG1/4: ≤1.0MPa, Others: ≤1.2MPaTemperatura d'emmagatzematge-25 °C a +80 °C
Humitat d'emmagatzematge25% -95% HRApplicable MediumNon-corrosive, clean, low-viscosity liquids
G1/4 model specific specifications
Specific parameters for the G1/4 model.

3. Configuració i instal·lació

3.1. Preparació

  • Verify that the selected model matches the required pipe thread specification and flow range.
  • Ensure the liquid to be measured is non-corrosive and free from solid particles.
  • Confirmeu que el volum de subministramenttage is within DC 3.5–24 V.

3.2. Instal·lació

  • Install the flow meter in the correct flow direction as indicated by the arrow on the housing.
  • Ensure proper sealing of threaded connections using appropriate sealing materials (e.g., PTFE tape).
  • Avoid mechanical stress on the sensor body during installation.

3.3. Connexió elèctrica

Connect the power supply and NPN pulse output according to the following wiring diagram. Ensure correct polarity before energizing the device.

Wiring instructions for the flow sensor
Wiring instructions: Red (IN) to positive (+), Yellow (OUT) for signal output, Black (GND) to negative (-).
  • Red (IN): Connect to positive (+)
  • Yellow (OUT): Sortida de senyal
  • Negre (GND): Connect to negative (-)

4. Funcionament

4.1. Funcionament inicial

Open the liquid supply gradually to avoid sudden pressure shocks to the sensor. During operation, maintain flow and pressure within the specified range to ensure accurate readings and prevent damage.

4.2. Data Reading

Measure the output pulse frequency from the yellow (OUT) wire. Calculate the flow rate using the corresponding frequency formula for your specific model (refer to the Specifications section). If total volume measurement is required, integrate the pulse counts over time.

Output waveform of the flow sensor
Example of the NPN pulse signal output waveform.

The sensor provides an NPN pulse signal output, which can be read by a microcontroller or other compatible device.

5. Manteniment

5.1. Emmagatzematge

  • Store the product in a dry and well-ventilated environment within the specified storage temperature range (-25°C to +80°C).
  • Avoid prolonged exposure to direct sunlight or corrosive atmospheres.
  • If the device is not used for an extended period, clean the internal flow path with a compatible liquid and dry thoroughly before storage.

5.2. Inspecció periòdica

  • Regularly inspect threaded connections and wiring to ensure secure installation and prevent leaks or disconnections.

6. Resolució de problemes i preguntes freqüents

Q: What is the wiring method?
A: Connect the red wire to positive (+), the black wire to negative (-), and the yellow wire is for signal output (NPN pulse signal).
Q: Can this sensor measure liquids with impurities?
A: No, this sensor is not designed for liquids containing impurities. It is intended for non-corrosive, clean, low-viscosity liquids.
Q: What if the rotor stops due to liquid solidification?
A: If the liquid solidifies and causes the internal rotor to stop turning, this is not considered a quality issue and will not be covered under warranty. Ensure the liquid remains in a low-viscosity state within the operating temperature range.
Q: What types of liquids can it measure?
A: It is mainly used for non-corrosive, low-viscosity liquids such as water, milk, oil, chemicals, paints, and detergents.

7. Precaucions i advertències de seguretat

ADVERTIMENT!

  • This device operates with electrical power. Incorrect wiring may cause electric shock or equipment damage.
  • Assegureu-vos que el vol operatiutage does not exceed DC 24 V.
  • Do not exceed the specified maximum pressure rating. Overpressure may result in rupture or leakage.
  • Not suitable for use with explosive, flammable, or highly viscous liquids unless specifically certified by the seller.
  • Prevent solid particles or magnetic debris from entering the meter, as they may affect measurement accuracy and cause damage.
  • Operate within specified temperature and humidity limits to maintain accuracy and service life.
  • Disconnect power before installation, removal, or maintenance.
  • Installation must be carried out by qualified technical personnel.
  • Mantenir fora de l'abast dels nens.
  • Proper disposal: Follow WEEE directives for electronic waste.

Note: The above warning information is for reference only. Final warning language must comply with the official language requirements of the destination EU country.

8. Consells d'usuari

  • For optimal performance, ensure the liquid is free of any particles that could obstruct the gear mechanism.
  • When connecting, double-check the polarity of the power supply to prevent damage to the Hall effect sensor.
  • Gradually introduce liquid flow to avoid sudden pressure spikes that could impact the sensor's integrity.

9. Suport i contacte

For technical consultations, bulk orders, or any inquiries, please feel free to contact us:

  • WhatsApp: +86 19542723588
  • Correu electrònic: celiachen008@gmail.com
Contact information with QR code
Contact details for support and inquiries.

SHANGHAI CHIKONG AUTOMATION INSTRUMENT CO., LTD

10. Producte acabatview Vídeo

Un acabatview of the manufacturing process and applications of industrial automation products, including flow sensors.

Documents relacionats - Plastic Gear Flow Sensor

Preview CERTEON FM-PS2216 Inline Optical Flow Sensor User Manual
Comprehensive user manual for the CERTEON FM-PS2216 inline optical flow sensor. Includes specifications, installation instructions, maintenance, and safety guidelines for liquid flow monitoring.
Preview TM02 / TM03 Hall Effect Water Flow Sensor Product Manual and Specifications
Detailed product manual for the CERTEON TM02 / TM03 Hall Effect Water Flow Sensor, covering specifications, installation instructions, precautions, and maintenance for precise low-flow monitoring applications.
Preview CERTEON Digital Oval Gear Flow Meter Product Manual
Comprehensive product manual for the CERTEON Digital Oval Gear Flow Meter, covering specifications, installation instructions, operation, maintenance, and safety warnings.
Preview FM-PS2216 Inline Optical Flow Sensor User Manual
User manual for the SONGGER FM-PS2216 Inline Optical Flow Sensor. Includes specifications, installation instructions, precautions, and maintenance guidelines for low-flow liquid systems.
Preview Electronic Turbine Flow Meter - Stainless Steel Digital Liquid Flow Meter Manual
Comprehensive product manual for the CERTEON Electronic Turbine Flow Meter, a stainless steel digital liquid flow meter designed for accurate measurement in various industrial applications. Includes specifications, installation, operation, precautions, and maintenance guidelines.
Preview LWGY Turbine Flow Meter User Manual | CERTEON 304 Stainless Steel
Comprehensive user manual for the CERTEON LWGY Turbine Flow Meter. Includes specifications, installation instructions, operation guidelines, and maintenance procedures for this 304 stainless steel liquid flow transmitter.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.