TOOLTOP ET928

TOOLTOP ET928 3-in-1 Handheld Digital Oscilloscope Multimeter Signal Generator User Manual

Model: ET928

1. Introducció

The TOOLTOP ET928 is a versatile 3-in-1 handheld device combining the functionalities of a digital oscilloscope, a multimeter, and a signal generator. Designed for electrical testing, DIY projects, and professional use, it offers high-speed sampling, a wide analog bandwidth, and a comprehensive range of measurement capabilities. This manual provides detailed instructions for the safe and effective operation, maintenance, and troubleshooting of your ET928 device.

2. Producte acabatview

2.1 Característiques clau

  • 50 Msps d'alta velocitat sampling chip Oscilloscope with 12MHz analog bandwidth.
  • One button to see the wave of voltage gear, automatic /conventional / single 3 waveform scanning modes.
  • Waveform range up to 200V/grid, The highest up to 1600Vpp measurement.
  • 6000 counts digital multimeter include voltage/current, resistance, capacitance, frequency, duty cycle, diode/on/off testing.
  • Relative value measurement, effectively eliminating lead resistance, distributed capacitance or interference signals.
  • Signal source outputs 3 types of waveforms: sine, triangle and square waveforms. Range, frequency, duty cycle adjustable.
  • Configured with replaceable 18650 lithium batteries, more environmentally friendly.
  • Overload protection 750mA:10A double fuse, double protection instrument.

2.2 Components del dispositiu

Diagram labeling the ports and controls of the TOOLTOP ET928
Figure 1: TOOLTOP ET928 Port and Control Description

The TOOLTOP ET928 features a clear layout for ease of use:

  • Llum indicador de càrrega: Indica l'estat de càrrega.
  • Interfície de càrrega: Port USB per carregar el dispositiu.
  • Multi-Function Buttons (F1-F4): Used for various menu selections and function controls.
  • Botó AUTO: Automatically adjusts oscilloscope settings for waveform display.
  • Botó DESA: Stores current data or waveform.
  • Backlight/signal output: Controls display backlight and signal generator output.
  • Data retention/storage: Manages saved measurements and waveforms.
  • Functional range knob: Rotary switch to select different measurement modes (e.g., V, mV, A, mA, Ω, Cx, Hz%, Diode, On/Off).
  • 10A current input terminal: Input for high current measurements.
  • Signal output/current input terminal: Dual-purpose terminal for signal generation and current input.
  • OSC VΩCx: Input terminal for oscilloscope, voltagMesures de e, resistència i capacitància.
  • COM input port: Common ground terminal for all measurements.
  • MAX 10A FUSE, MAX 600mA FUSE: Fuse protection for current inputs.
  • CAT II 1000V: Safety rating for voltage mesures.

2.3 Finalització funcionalview

Diagram illustrating the diversified functions of the TOOLTOP ET928
Figure 2: Diversified Functions of the ET928

The ET928 integrates multiple functions to meet diverse work needs, including:

  • Multímetre: Mesures voltage (AC/DC), current (AC/DC), resistance, capacitance, frequency, diode, and performs on/off tests.
  • Oscil·loscopi: Displays waveforms with 12MHz bandwidth and 50Msps sampllengüeta
  • Generador de senyal: Outputs sine, square, and triangular waveforms with adjustable parameters.
  • Colorful Lighting: Provides visual feedback for different modes.
  • Emmagatzematge de dades: Stores measurement data and waveforms.

2.4 Additional Particulars

Particulars of the TOOLTOP ET928: Adjustable backlight, Beep alarm, Soft rubber sheath, and Rear cover bracket.
Figure 3: Device Particulars
  • Retroil·luminació ajustable: For clear visibility in various lighting conditions.
  • Beep Alarma: Provides audible alerts for certain functions or conditions.
  • Soft Rubber Sheath: Enhances durability and provides protection against impacts.
  • Rear Cover Bracket: Allows the device to stand upright for convenient viewing.

3. Especificacions

3.1 Paràmetres tècnics

Table of Technical Parameters for the TOOLTOP ET928
Figura 4: Paràmetres tècnics
ParàmetreValor
Mostra320*240 color display LCM
Llum de fonsBlanc
BateriaLithium battery (18650 type)
Recordatori de bateria baixa
Temps d'úsUnes 6 hores
Entorn d’ús0°C ~ +40°C, <75%RH
Dimensions totals153 mm * 75 mm * 30 mm
Amplada de banda analògicaACV/DCV ≤ 12MHz
Sortida de la font de senyalSquare wave, triangular wave, sine wave
Zona d’observació2.4 polzades
Resistència d'entrada10 MΩ
Apagat automàtic
Consum d'energiaUns 250 mA
Capacitat d'emmagatzematge100 sets of DMM data + 10 waveforms
Condicions d'emmagatzematge-10 °C ~ +60 °C, <90% RH
Màxim samptaxa de ling50 msps

3.2 Paràmetres de la funció

Table of Function Parameters for the TOOLTOP ET928
Figure 5: Function Parameters
CategoriaIntervalLa incertesa
DC voltage60mV/600mV, 6V/60V/600V/1000V(0.75% de lectura + 10 dgt)
AC voltage60mV/600mV, 6V/60V/600V/750V(1.0% de lectura + 10 dgt)
corrent DC600uA/6000uA, 60mA/500mA, 6A/10A(1.2% de lectura + 10 dgt)
Corrent altern600uA/6000uA, 60mA/500mA, 6A/10A(1.5% de lectura + 10 dgt)
Resistència600.00 Ω ~ 60.00MΩ(1.0% de lectura + 5 dgt)
Condensadors10nF ~ 100mF(2% de lectura + 10 dgt)
Freqüència5Hz ~ 100KHz (Merge voltage shift) 5Hz ~ 10MHz(1.0% de lectura + 5 dgt)
Cicle de treball0.1% ~ 99.9% (Merge voltage shift)(1.0% de lectura + 5 dgt)
Prova de díodesCircuit obert voltage about 3V, max test current about 2mA
Prova on-offJudging resistance: approximately <50 Ω
Fusible500mA/250V, 10A/250V

4. Configuració

4.1 Càrrega inicial

Before first use, ensure the device is fully charged. Connect the provided USB cable to the charging interface on the device and to a suitable USB power source. The charging indicator light will show the charging status.

4.2 Connexió dels cables de prova

Insert the red test lead into the VΩCx input terminal and the black test lead into the COM input terminal for most measurements (voltage, resistance, capacitance, oscilloscope). For high current measurements (up to 10A), insert the red test lead into the 10A current input terminal and the black test lead into the COM terminal. For lower current measurements (up to 500mA), use the signal output/current input terminal for the red lead and COM for the black lead.

4.3 Engegada/apagada

To power on the device, press and hold the power button (usually integrated with the functional range knob or a dedicated button, refer to Figure 1). To power off, press and hold the same button. The device also features an automatic shutdown function to conserve battery life.

5. Instruccions de funcionament

5.1 Mode d'oscil·loscopi

Oscilloscope display showing a perfect waveform with AUTO, NORMAL, and SINGLE collection modes.
Figure 6: Oscilloscope Waveform Collection Modes

Turn the functional range knob to the 'OSC' position to enter oscilloscope mode. The ET928 offers three waveform scanning modes:

  • AUTOMÀTIC: Automatically captures and displays waveforms without requiring specific triggering conditions.
  • NORMAL: Similar to AUTO, captures waveforms without manual trigger setup.
  • SOLTER: Captures a single waveform event when a trigger condition is met.

Use the F1-F4 buttons to navigate menus and adjust parameters such as time base, voltage division, and trigger settings. The 'AUTO' button can quickly optimize the waveform display.

5.2 Mode multímetre

Multimeter functions demonstrating AC voltage measurement and resistance measurement.
Figure 7: Multimeter AC Voltage and Resistance Measurement
Multimeter manual/automatic modes for Capacitance, Frequency, Diode, and Duty Cycle measurements.
Figure 8: Multimeter Capacitance, Frequency, Diode, and Duty Cycle Measurement

Rotate the functional range knob to select the desired measurement function (e.g., VDCX for DC voltage, VACX for AC voltage, Ω for resistance, Cx for capacitance, Hz% for frequency/duty cycle, Diode for diode test, On/Off for continuity test). Connect the test leads appropriately for the selected measurement. The device supports both manual and automatic ranging.

5.3 Mode generador de senyals

Oscilloscope signal generator output showing adjustable frequency, amplitude, and duty cycle for Sine, Square, and Triangular waveforms.
Figure 9: Signal Generator Output Waveforms

The ET928 can generate sine, square, and triangular waveforms. To use this function, select the signal generator mode (often integrated with the oscilloscope or a dedicated function). Use the F-buttons to adjust the frequency, amplitude, and duty cycle of the output signal. Connect the signal output terminal to the circuit or device you wish to test.

  • Ona sinusoïdal: 100Hz ~ 100kHz
  • Ona quadrada: 100Hz ~ 20kHz
  • Ona triangular: 100Hz ~ 50kHz

5.4 Emmagatzematge de dades

Data storage feature, showing multiple saved waveforms and data sets.
Figure 10: Data Storage Interface

The device can store up to 100 sets of DMM data and 10 waveforms. To save the current measurement or waveform, press the 'SAVE' button. Navigate through saved data using the F-buttons or menu options.

5.5 Mode silenciós

Quiet Mode activation: Hold down F4 key while turning the knob to turn on the machine to enter mute mode.
Figure 11: Activating Quiet Mode

To activate Quiet Mode and disable button sounds, hold down the F4 key while turning the functional range knob to power on the device. This allows for silent operation in sensitive environments.

6. Manteniment

6.1 Neteja

Regularly clean the device with a soft, dry cloth. Do not use abrasive cleaners or solvents, as they may damage the casing or display. Ensure the device is powered off and disconnected from any power source before cleaning.

6.2 Substitució de la bateria

The ET928 uses a replaceable 18650 lithium battery. If the battery performance degrades significantly, it can be replaced. Refer to the warning label on the rear of the device: "TO AVOID ELECTRICAL SHOCK, DO NOT TEST READS BEFORE OPENING CASE." Only qualified personnel should attempt battery replacement. Ensure the device is powered off and disconnected before opening the battery compartment.

6.3 Canvi de fusibles

The device is protected by 750mA and 10A double fuses. If current measurement functions cease to work, a fuse may need replacement. Fuse replacement should only be performed by qualified personnel. Ensure the device is powered off and disconnected from any power source before opening the casing per accedir als fusibles.

6.4 Emmagatzematge

When not in use for extended periods, store the device in a cool, dry place with temperatures between -10 °C and +60 °C and relative humidity below 90% RH. Avoid direct sunlight, extreme temperatures, and high humidity. It is recommended to charge the battery periodically if stored for a long time to maintain battery health.

7. Solució De Problemes

If you encounter issues with your TOOLTOP ET928, please consider the following general troubleshooting steps:

  • El dispositiu no s'encén: Ensure the battery is charged. Connect the USB cable and attempt to power on while charging.
  • Lectures inexactes: Check test lead connections. Ensure the correct measurement mode is selected. Verify that the probes are making good contact with the circuit.
  • No waveform display in oscilloscope mode: Check trigger settings. Use the 'AUTO' button to attempt automatic waveform detection. Ensure the input signal is within the device's voltage gamma.
  • No sound in Quiet Mode: This is expected behavior. If you wish to re-enable sounds, power off the device and power it on normally without holding F4.
  • La mesura de corrent no funciona: Check the fuses. If a fuse is blown, it will need to be replaced by a qualified technician.

Per a problemes persistents, poseu-vos en contacte amb l'atenció al client.

8. Consells d'usuari

No hi havia consells específics per a l'usuari disponibles a partir del material proporcionat.viewContingut de preguntes i respostes.

9. Contingut del paquet

Accessories included with the TOOLTOP ET928: the device, test leads, USB cable, user manual, and packaging box.
Figura 12: Contingut del paquet

The standard package for the TOOLTOP ET928 includes:

  • 1 x TOOLTOP ET928 Oscilloscope Multimeter Signal Generator
  • 1 x parell de cables de prova
  • 1 x manual d'usuari en anglès
  • 1 x cable USB
  • 1 x Caixa de paquet