Smart Meter ATMS100133Z

Three Phase Zigbee Smart Meter (ATMS100133Z) Instruction Manual

Intelligent Energy Monitoring with Split Core Current Transformers

1. Introducció

This manual provides comprehensive instructions for the installation, operation, and maintenance of your Three Phase Zigbee Smart Meter, model ATMS100133Z. This device is designed for accurate energy monitoring in three-phase four-wire electrical systems, offering real-time data and remote control capabilities via the Tuya Smart App. Please read this manual carefully before installation and use to ensure safe and efficient operation.

Three Phase Zigbee Smart Meter with three split-core current transformers
Figure 1: Three Phase Zigbee Smart Meter (ATMS100133Z) with Split Core Current Transformers

2. Informació de seguretat

▲ Avís:

  • Do not use this product in extreme environments such as high temperature, high humidity, dusty, or flammable areas.
  • Avoid subjecting the product to severe impacts or vibrations.
  • Do not disassemble, modify, or repair this product yourself. Unauthorized modifications can lead to electric shock, fire, or damage to the device.
  • Mantenir fora de l'abast dels nens.
  • Ensure all electrical connections are made by a qualified electrician in accordance with local electrical codes and regulations.

3. Contingut del paquet

Before proceeding with installation, please verify that all accessories are present and in good condition:

  • 1 x Three-phase Zigbee Smart Meter (ATMS100133Z)
  • 3 x Split Core Current Transformers

4. Especificacions

ParàmetreValor
ModelATMS100133Z
Volum nominaltage100-240 V CA (50/60 Hz)
Interval d'operació(0.8...1.1) Un (180~260V)
Potència nominal2.2VA/0.7W
Interval actual0.02A-100A
Corrent nominalFins a 100A
Pols3 Phase 4 Wire, 4P
Freqüència WiFi2.4 GHz
Compatibilitat d'aplicacionsAplicació Tuya Smart
Classe de precisióClasse 0.5
Ràtio CT1000:1
Interval de temperatura ambient-20 ℃ a + 60 ℃
MuntatgeDIN Rail 35 mm (EN 60715)
Dimensions90 x 65.5 x 18 mm
MaterialABS
ColorGray + Black

5. Configuració i instal·lació

The ATMS100133Z Smart Meter is designed for easy installation, particularly with its split-core current transformers that eliminate the need for cutting wires. It mounts on a standard 35mm DIN rail.

5.1 Mounting the Smart Meter

  1. Ensure the main power supply to the circuit you intend to monitor is completely turned off at the breaker.
  2. Locate a suitable position on a 35mm DIN rail within your electrical panel.
  3. Attach the smart meter to the DIN rail by aligning its back-mounted clips with the rail and pressing firmly until it clicks into place.
Smart meter mounted on a DIN rail
Figure 2: Smart Meter Mounted on DIN Rail

5.2 Wiring the Smart Meter and Current Transformers

The smart meter requires connection to the neutral and live wires of your three-phase system. The split-core current transformers (CTs) are used to measure current without direct contact with the main conductors.

  1. Connexió d'alimentació: Connect the L1, L2, L3 (Live phases) and N (Neutral) wires from your main access switch to the corresponding terminals on the smart meter. The nominal voltage és 100-240 V AC.
  2. Current Transformer (CT) Installation:
    • For each phase (L1, L2, L3), open one split-core current transformer.
    • Amb cura clamp each CT around a single live wire (L1, L2, L3 respectively) that you wish to monitor. Ensure the CT is securely closed.
    • Connect the red and black wires from each CT to the corresponding B1/R1, B2/R2, B3/R3 terminals on the smart meter. Ensure correct polarity if indicated on the CTs or meter.
  3. Comproveu dues vegades que totes les connexions estiguin ben ajustades i correctes abans de restablir l'alimentació.
Detailed wiring diagram for the three-phase smart meter
Figure 3: Wiring Diagram for Three Phase Smart Meter

5.3 App Connection (Tuya Smart App)

  1. Download the 'Tuya Smart' app from your smartphone's app store (available for iOS and Android).
  2. Registra't o inicia la sessió al teu compte de Tuya Smart.
  3. Ensure your smartphone is connected to a 2.4GHz WiFi network. The smart meter only supports 2.4GHz WiFi.
  4. Restore power to the smart meter. The WiFi indicator on the meter should start blinking. If not, press and hold the 'Touch 5s to Connect' button on the meter for 5 seconds until it blinks rapidly.
  5. In the Tuya Smart app, tap '+' to add a new device.
  6. Follow the in-app instructions to discover and connect your smart meter. You may need to select 'Electrical' > 'Meter' or 'Energy Monitor'.
  7. Once connected, you can rename the device and assign it to a specific room or location.
Smart meter connected to a smartphone displaying the Tuya Smart App
Figure 4: Connecting the Smart Meter to the Tuya Smart App

6. Funcionament

Once installed and connected to the Tuya Smart App, your ATMS100133Z Smart Meter provides comprehensive energy monitoring and management features.

6.1 Monitorització en temps real

Through the Tuya Smart App, you can monitor the following key metrics in real-time:

  • Voltage (V) for each phase
  • Current (A) for each phase
  • Potència activa (kW)
  • Reactive Power (kVar)
  • Factor de potència
  • Total Active Energy (kWh)
  • Forward Energy (grid consumption)
  • Reverse Energy (solar generation, if applicable)
Smartphone screen displaying energy monitoring data via the Tuya Smart App
Figure 5: Tuya Smart App Interface for Energy Monitoring

6.2 Data Tracking and Analysis

The app records historical energy data, allowing you to:

  • Track total active energy consumption over time.
  • Analyze energy usage patterns to identify peak consumption periods.
  • Monitor solar power contributions (reverse energy) for optimization.
  • Detect anomalies in power usage that might indicate faulty appliances or inefficiencies.

6.3 Multi-User Sharing and Smart Alerts

  • Compartició de dispositius: Share access to your smart meter's data with family members or team members through the Tuya Smart App for collaborative energy management.
  • Alertes intel·ligents: Configure custom alerts for high consumption, voltage fluctuations, or other parameters to receive notifications and take timely action.

7. Manteniment

The ATMS100133Z Smart Meter is designed for reliable operation with minimal maintenance. Follow these guidelines to ensure its longevity and accurate performance:

  • Neteja: Periodically wipe the device with a soft, dry cloth to remove dust. Do not use liquid cleaners or solvents.
  • Condicions ambientals: Ensure the operating environment remains within the specified temperature range (-20℃ to +60℃) and avoid excessive humidity.
  • Inspecció física: De tant en tant, reviseu les connexions del cablejat per assegurar-vos que es mantinguin ben fixades.
  • Actualitzacions de firmware: Keep the Tuya Smart App updated to the latest version to receive performance improvements and new features. The device firmware may also be updated via the app.

8. Solució De Problemes

If you encounter issues with your smart meter, refer to the following common problems and solutions:

8.1 Cannot Install / Device Not Fitting

  • Comprovar la compatibilitat: Ensure the device model is compatible with your electrical panel and DIN rail specifications.
  • Obstruccions: Verify that there are no foreign objects obstructing the installation area or the DIN rail clips.

8.2 Device Not Connecting to App / WiFi Issues

  • WiFi de 2.4 GHz: Confirm your router is broadcasting a 2.4GHz WiFi signal and your phone is connected to it during setup. The meter does not support 5GHz WiFi.
  • Intensitat del senyal: Ensure the smart meter is within range of your WiFi router.
  • Restablir WiFi: Press and hold the 'Touch 5s to Connect' button on the meter for 5 seconds until the WiFi indicator blinks rapidly to enter pairing mode.
  • Versió de l'aplicació: Make sure your Tuya Smart App is up to date.

8.3 Lectures inexactes

  • CT Installation: Ensure each split-core current transformer is correctly clamped around a single live wire and securely closed. Incorrect installation can lead to inaccurate readings.
  • Cablejat: Verify that all wiring connections (L1, L2, L3, N, and CT wires) are correct and tight.
  • Calibració: While the meter is factory calibrated, significant discrepancies should be reported to support.

9. Consells d'usuari

  • Eficiència energètica: Regularment review your energy consumption data in the Tuya Smart App to identify high-usage periods or appliances. This can help you make informed decisions to reduce waste and save on electricity bills.
  • Solar Monitoring: If you have solar panels, utilize the bi-directional measurement feature to track both grid consumption and solar generation, optimizing your energy independence.
  • Anomaly Detection: Pay attention to sudden spikes or unusual patterns in your energy data, which could indicate a malfunctioning appliance or an electrical issue.
  • Compartició de dades: Share access with household members to foster a collective effort towards energy conservation.

10. Garantia i Suport

For detailed warranty information and customer support, please refer to the seller's policies or contact the vendor directly. A comprehensive user manual in PDF format is also available for download:

User manual (PDF): Descarrega el manual en PDF

Documents relacionats - ATMS100133Z

Preview Smart Meter iScale Cellular Weight Scale SMSC2001 User Manual
Comprehensive user manual for the Smart Meter iScale Cellular Weight Scale (Model SMSC2001-G-001). Learn how to set up, use, and maintain your smart scale for accurate weight tracking and health monitoring. Includes troubleshooting, specifications, and warranty details.
Preview Manual d'usuari de l'iBloodPressure Classic SMBP-802-Gb-001
Manual d'usuari complet per al monitor de pressió arterial mòbil SMART METER iBloodPressure Classic (SMBP-802-Gb-001), que cobreix la configuració, el funcionament, el mesurament, la resolució de problemes i les especificacions.
Preview Guia d'inici ràpid i resolució de problemes del glucòmetre TeleRPM
Guia d'inici ràpid i informació de resolució de problemes per al mesurador de glucosa en sang Smart Meter TeleRPM (model SMBGM-TMB-2282-G). Apreneu a configurar i utilitzar el mesurador i a resoldre problemes comuns.
Preview Manual d'usuari del monitor de pressió arterial mòbil iBloodPressure®
Manual d'usuari del monitor de pressió arterial cel·lular iBloodPressure® (model SMBP802-GS-001), que detalla les seves característiques, funcionament, precaucions de seguretat, resolució de problemes i especificacions.
Preview Smart Meter AES-U214 Arm Blood Pressure Monitor User Manual
Comprehensive user manual for the Smart Meter AES-U214 Arm Blood Pressure Monitor, covering setup, operation, maintenance, safety information, and troubleshooting. Learn how to accurately measure blood pressure and pulse rate at home.
Preview iGlucose Touch: Cellular-Connected Blood Glucose Monitoring System for RPM
Explore the iGlucose Touch, a cellular-connected blood glucose meter designed for Remote Patient Monitoring (RPM). Discover its features, specifications, and benefits for healthcare providers and patients, including real-time data transmission and a user-friendly touchscreen interface.