ANERN AN-FGI-DU4200

Anern AN-FGI-DU4200 Hybrid Solar Inverter

Manual d’instruccions de l’usuari

1. Producte acabatview

The Anern AN-FGI-DU4200 is a versatile hybrid solar inverter designed to provide reliable power for various applications. It features dual voltage operation (12VDC or 24VDC), pure sine wave output, and an intelligent charging design to optimize battery usage. This inverter supports simultaneous power supply from solar energy and the utility grid, and is compatible with both mains and generators. It includes comprehensive protection features and offers optional WiFi remote monitoring.

Anern Hybrid Inverter AN-FGI-DU4200 overview
Figure 1: Anern Hybrid Inverter AN-FGI-DU4200 overview, highlighting 4200W power, 12VDC/24VDC compatibility, 100A Max charging current, 500V Max DC Voltage, 2 Year Warranty, Optional WIFI Mode, CE FCC RoHS certifications.

Característiques principals:

  • Vol dobletage operation: 12VDC or 24VDC, meeting diverse load requirements.
  • Rated power: 2300W (at 12VDC) and 4200W (at 24VDC).
  • Sortida d'ona sinusoidal pura per a electrònica sensible.
  • Vol d'entrada seleccionabletage range for utility grid (household appliances/personal computers).
  • Customizable charging current via LCD display.
  • Simultaneous power supply from solar energy and utility grid.
  • AC input compatible with both mains and generators.
  • Automatic restart function upon mains power restoration.
  • Protecció contra sobrecàrrega, sobretemperatura i curtcircuit.
  • Intelligent battery charging design for extended battery life.
  • RS485 port for communication with Battery Management Systems (BMS).
  • Funció d'arrencada en fred.
  • Built-in MPPT with an operating voltage range of 55V~500V and open circuit voltage of 500Voc.
  • Optional WiFi remote monitoring and Bluetooth near-end sampllengüeta
  • Kit antipols integrat per a entorns durs.

2. Configuració i instal·lació

2.1 Instal·lació física

The inverter should be installed in a well-ventilated area, away from direct sunlight, heat sources, and flammable materials. Ensure sufficient clearance around the unit for proper airflow. Refer to the product display image for dimensions and port locations.

Product Display with dimensions and rear panel connections
Figure 2: Product dimensions (530mm H, 390mm W, 130mm D) and rear panel connections including AC IN, AC OUT, Input Breaker, Battery terminals, and PV IN.

2.2 Connexions de cablejat

All wiring should be performed by a qualified electrician in accordance with local electrical codes and regulations. Ensure all connections are secure and properly insulated.

2.2.1 Connexió de la bateria

The inverter supports both 12VDC and 24VDC battery systems. Ensure your battery bank matches the selected operating voltage of the inverter. The inverter is compatible with various battery types including Flooded (FLD), GEL, AGM, Lithium (LI), Sealed (SLD), and User Custom Battery (USER).

Battery Connection Diagram for 12V Parallel and 24V Series
Figure 3: Diagram showing parallel connection for 12V batteries (for 12V inverter mode) and series connection for 24V batteries (for 24V inverter mode). Also lists supported battery types.

2.2.2 Solar Panel, Generator, and Load Connections

Connect your solar panel array, generator (if used), and household loads to the designated terminals on the inverter. Follow the wiring diagram carefully to ensure correct and safe operation.

Hybrid Power System Wiring Diagram
Figure 4: Comprehensive wiring diagram for a hybrid power system, illustrating connections for solar panels, combiner box, DC disconnect, AC breaker panel, AC disconnect, inverter, kWh meter, generator, external battery packs, and various home appliances.

2.3 Configuració inicial

After all physical connections are made, power on the inverter. Use the LCD display to set the desired operating parameters, including battery type, charging current, and utility grid input voltage range, according to your system's requirements.

3. Instruccions de funcionament

3.1 Engegada/apagada

  1. Ensure all wiring is correct and secure before powering on.
  2. Turn on the battery breaker first, then the solar array breaker (if applicable).
  3. Finally, turn on the inverter's main power switch.
  4. To power off, reverse the sequence: inverter switch off, then solar, then battery.

3.2 Pantalla LCD i configuració

The integrated LCD display provides real-time system status and allows for configuration of various parameters. Navigate through the menus using the control buttons to adjust settings such as:

  • Corrent de càrrega de la bateria: Adjust the charging current to suit your battery bank's specifications.
  • Utility Grid Input Voltage Rang: Select the appropriate range for your connected loads (e.g., for personal computers or home appliances).
  • Mode de funcionament: Choose between different priority modes for solar, utility, and battery power.

3.3 Dual Power Source Operation

The inverter is designed to intelligently manage power from both solar panels and the utility grid. It can power loads simultaneously from both sources, prioritizing solar power when available to reduce reliance on the grid.

3.4 Automatic Restart Function

In the event of a utility grid outage, the inverter will automatically switch to battery/solar power. When mains power is restored, the inverter will automatically restart and resume normal operation, including battery charging.

3.5 WiFi Monitoring (Optional)

If equipped with the optional WiFi module, the inverter's operation can be remotely monitored via a mobile application or computer. This allows for convenient tracking of system performance and status from anywhere.

WI-FI Monitoring setup diagram
Figure 5: Diagram illustrating the connection of the inverter to a WiFi module for remote monitoring via computer or mobile phone.

4. Manteniment

Regular maintenance ensures the longevity and optimal performance of your Anern Hybrid Solar Inverter.

  • Neteja: Periodically clean the exterior of the inverter with a dry, soft cloth. Ensure ventilation openings are free from dust and debris. The built-in anti-dust kit helps in harsh environments, but regular checks are still recommended.
  • Connexions: Inspeccioneu anualment totes les connexions elèctriques (bateria, solar, entrada/sortida de CA) per comprovar si estan ben ajustades i si hi ha signes de corrosió. Estrenyeu qualsevol connexió solta.
  • Medi ambient: Ensure the inverter remains in a cool, dry, and well-ventilated environment within the specified operating temperature and humidity ranges.
  • Salut de la bateria: Monitor your battery bank's health and perform maintenance as recommended by the battery manufacturer.

5. Solució De Problemes

The inverter is equipped with protection features to prevent damage. If you encounter issues, refer to the following common troubleshooting steps:

  • Sense potència de sortida: Check all input power sources (solar, utility, battery) and their respective breakers/fuses. Ensure the inverter is properly switched on.
  • Protecció de sobrecàrrega: If the inverter shuts down due to overload, reduce the connected load and restart the unit. Ensure the total load does not exceed the inverter's rated power.
  • Protecció de sobretemperatura: If the inverter overheats, it will shut down. Check for obstructions around the ventilation openings and ensure the ambient temperature is within the operating range. Allow the unit to cool down before restarting.
  • Protecció contra curtcircuits: The inverter will protect itself from short circuits. Identify and resolve any short circuits in the wiring or connected loads before restarting.
  • Codis d'error: Refer to the inverter's LCD display for any error codes. Consult the full product manual (if available) for specific error code interpretations and solutions.
  • BMS Communication Issues: If using a BMS, ensure the RS485 connection is secure and the BMS is functioning correctly.

Si els problemes persisteixen després de seguir aquests passos, poseu-vos en contacte amb l'atenció al client.

6. Especificacions

Below are the detailed technical specifications for the Anern AN-FGI-DU4200 Hybrid Solar Inverter:

Product Data Sheet with detailed specifications
Figure 6: Detailed Product Data Sheet outlining specifications for 12V and 24V modes.
Anern AN-FGI-DU4200 Technical Specifications
ParàmetreSistema 12VSistema 24V
Número de modelAN-FGI-DU4200
Potència de sortida nominal2300VA/2300W4200VA/4200W
Entrada Voltage230 VCA
Vol. Seleccionabletage Range (PC)170-280VAC
Vol. Seleccionabletage Range (Home Appliances)90-280VAC
Interval de freqüència50 Hz/60Hz (Auto Sensing)
Vol. ACtagRegulació electrònica (mode bateria)230VAC ± 5%
Potència de sobretensió4600W8400W
Eficiència (màxima) de la bateria a INV94%
Transfer Time (PC)10 ms
Transfer Time (Home Appliances)20 ms
Voltage12 V24 V
Càrrega flotant Voltage13.5 V27 V
Protecció de sobrecàrrega16VDC32VDC
Corrent de càrrega màxima100A
Potència màxima de matriu fotovoltaica4000W
Interval MPPT @ Voltage55-500VDC
Volum màxim de circuit obert de la matriu fotovoltaicatage500VDC
Mida (H*W*D)405*305*108 mm
Pes net6.7 kg
Interfície de comunicacióRS485/RS232, BMS/WiFi/Bluetooth
Humitat5% a 95% d'humitat relativa (sense condensació)
Temperatura de funcionament-20 °C ~ 55 °C
Temperatura d'emmagatzematge-20 °C ~ 60 °C

7. Garantia i Suport

The Anern AN-FGI-DU4200 Hybrid Solar Inverter comes with a 2 any de garantia des de la data de compra. Aquesta garantia cobreix els defectes de materials i de fabricació en condicions d'ús i manteniment normals.

For technical support, warranty claims, or any questions regarding the operation or maintenance of your inverter, please contact the seller or authorized service center. Provide your product model number (AN-FGI-DU4200) and purchase details when seeking assistance.

8. Consells d'usuari

  • Col·locació òptima: Install the inverter in a location that allows for good air circulation to prevent overheating, especially during peak operation.
  • Coincidència de bateries: Always ensure your battery bank voltage (12V or 24V) is correctly configured on the inverter and matches the physical battery setup (parallel for 12V, series for 24V).
  • Gestió de càrrega: Be mindful of the total power consumption of your connected appliances to avoid overloading the inverter, particularly when operating at 12VDC (2300W rated power).
  • Seguiment periòdic: Utilize the LCD display or the optional WiFi monitoring feature to keep track of your system's performance, battery status, and energy flow.
  • Connexions netes: Periodically check and clean all electrical terminals to ensure efficient power transfer and prevent potential issues.

Documents relacionats - AN-FGI-DU4200

Preview ANERN FGI-S12000 Hybrid Solar Inverter User Manual
User manual for the ANERN FGI-S12000 Hybrid Solar Inverter. This guide details the installation, operation, safety, and specifications of the 12KW solar energy storage system, featuring MPPT charge control and UPS functionality.
Preview Anern MPPT Solar Inverter Product Manual: AN-FGI-AS12000 & AN-FGI-AS12000P
Comprehensive product manual for Anern AN-FGI-AS12000 and AN-FGI-AS12000P MPPT solar inverters. Covers installation, operation, safety, troubleshooting, and technical specifications for efficient solar energy management.
Preview Anern AN-FGI-AS7200/AS7200P MPPT Solar Inverter Product Manual | Installation & Operation Guide
Comprehensive product manual for Anern AN-FGI-AS7200 and AN-FGI-AS7200P MPPT Solar Inverters. Learn about installation, operation, features, safety, and technical specifications for hybrid solar energy systems.
Preview Manual d'usuari de l'inversor híbrid d'ona sinusoidal pura d'Anern: Guia d'instal·lació, seguretat i funcionament
This user manual provides comprehensive safety, installation, and operation guidelines for the Anern Pure Sine Wave Hybrid Inverter. It covers essential information on tools, wiring, and system setup for reliable power solutions.
Preview Anern FGI-S4000 MPPT Solar Inverter User Manual
User manual for the Anern FGI-S4000 MPPT Solar Inverter, detailing installation, operation, safety, and troubleshooting for solar energy storage systems.
Preview AN-FGI-AS10000P MPPT Solar Inverter User Manual
This comprehensive product manual from Guangzhou Anern Energy Technology Co., Ltd. details the assembly, installation, operation, and troubleshooting of their AN-FGI-AS10000P MPPT Solar Inverter. It provides essential guidance for users and qualified personnel, highlighting advanced MPPT technology, dual battery support, and flexible operation modes for efficient energy management.