1. Introducció
This manual provides essential information for the safe and effective use of the EYE JCR12V100W10H/G1/IR Dichroic Infrared Lamp. This high-quality halogen bulb is designed for various professional applications requiring precise illumination and infrared output, including medical, scientific, industrial, and photographic equipment.
Important Note: Please ensure you have the correct model. This lamp is the JCR12V100W10H/G1/IR (Infrared Dichroic) version. Do not confuse it with the JCR12V100W10H/G1/AL (Aluminum Reflector) version, as their optical properties and applications differ significantly.

Figure 1: EYE JCR12V100W10H/G1/IR Dichroic Infrared Lamp en el seu embalatge.
2. Especificacions
2.1 Especificacions generals
- Model: JCR12V100W10H/G1/IR
- Tipus: Dichroic Infrared Halogen Lamp
- Voltage: 12 V
- Wattage: 100W
- Lamp Base: GZ6.35
- Vida nominal: Aproximadament 1000 hores
- Origen: Fabricat al Japó
2.2 Característiques físiques

Figure 2: Close-up of the JCR12V100W10H/G1/IR lamp with GZ6.35 pins.
2.3 Compatible Lamp Holders (Exampells)

Figura 3: Examples of compatible AMP Holders and OEM Kit specifications.
El lamp is compatible with GZ6.35 lamp holders. Examples of compatible AMP Holders include (but are not limited to) models such as BJB, VS32400, VS32700, B+W 901, C18A003, B+W 913, B+W 830, OEW-1, and OEW-0, with corresponding G4, G4-G6.35, GX5.3, GZ6.35, and GY9.5 sizes/bases.
2.4 Application-Specific Specifications

Figure 4: Specifications for AOI, PCB, Photo, and Enlarge Lamps.
The JCR12V100W10H/G1/IR lamp is suitable for various applications. For instance, in AOI (Automated Optical Inspection) and PCB (Printed Circuit Board) industries, similar 12V 100W lamps with 50h life are used. In photography and enlarging, lamps with various ANSI codes, voltages (e.g., 36V, 230V, 12V, 24V, 120V, 150V), wattages (e.g., 300W, 100W, 150W, 36W, 55W, 120W, 150W), bases (e.g., GX6.35, GZ6.35, G22, GZ4), and life hours (e.g., 25h, 15h, 20h, 50h, 8000h, 4000h) are common.

Figure 5: Specifications for Medical Operation Room and Dental Lamps.
In medical and dental fields, lamps with similar characteristics are utilized. For example, medical operation room lamps can have ANSI codes like 13938, JM, 6424V, 64F42, BLUF 64F42, 567901947, CZ, with voltages ranging from 22.8V to 24V, wattages from 40W to 150W, and bases like GX5.3, G4, G6.35. Dental lamps, including models like JCR/M10V52W, JCR12V75W, JCR/M12V100W, JCR/M14V36W, feature voltages from 10V to 14V, wattages from 36W to 100W, and GZ4/G6.35 bases, often used for curing applications.
3. Configuració i instal·lació
3.1 Precaucions de seguretat
- Always disconnect power to the fixture before installing or replacing the lamp.
- Allow the old lamp to cool completely before handling to prevent burns.
- Avoid touching the glass envelope of the new lamp with bare hands. Oils from your skin can create hot spots, reducing lamp life. Use a clean, lint-free cloth or gloves.
- Assegureu-vos que lamp is securely seated in the lamp titular.
- Comproveu que el voltage i wattage de la lamp match the requirements of your fixture.
3.2 Passos d'instal·lació
- Turn off the power supply to the lighting fixture and allow it to cool down.
- Traieu amb cura l'antiga lamp from its GZ6.35 socket.
- Holding the new EYE JCR12V100W10H/G1/IR lamp with a clean cloth or gloves, align its two pins with the holes in the GZ6.35 lamp titular.
- Empenyeu suaument la lamp into the socket until it is firmly seated. Do not force it.
- Un cop lamp is installed, restore power to the fixture.
- Prova la lamp per garantir un funcionament correcte.
4. Funcionament
The EYE JCR12V100W10H/G1/IR lamp operates by converting electrical energy into light and infrared radiation. Once properly installed and powered, the lamp will illuminate and emit its characteristic infrared spectrum. This lamp is commonly used in:
- Equip mèdic: Such as operating room lights and dental curing lights.
- Scientific Instruments: For microscopy, endoscopy, and other analytical applications.
- Aplicacions industrials: Including Automated Optical Inspection (AOI) and PCB manufacturing.
- Photography and Projection: For specialized lighting and enlarging equipment.
Ensure that the equipment housing the lamp has adequate ventilation to dissipate heat generated during operation, as halogen lamps can reach high temperatures.
5. Manteniment
5.1 Neteja
Si la lamp's glass envelope becomes dirty or smudged, turn off the power and allow the lamp to cool completely. Gently wipe the glass with a clean, lint-free cloth moistened with isopropyl alcohol. Ensure the lamp is completely dry before re-applying power.
5.2 Substitució
El lamp has a rated life of approximately 1000 hours. When the lamp reaches the end of its life or fails, follow the installation steps in Section 3.2 to replace it. Always dispose of old lamps according to local regulations for electronic waste.
6. Solució De Problemes
| Problema | Causa possible | Solució |
|---|---|---|
| Lamp no s’encén | Sense poder per fixar Lamp not seated correctly Lamp has reached end of life Faulty fixture/socket | Check power supply and switch Torneu a col·locar la lamp fermament Substituïu la lamp Inspect fixture wiring and socket |
| Reduced brightness or flickering | Lamp a prop del final de la vida Vol incorrectetage subministrament Brut lamp superfície Connexió fluixa | Substituïu la lamp Comproveu la font d'alimentació voltage Netegeu la lamp surface (see 5.1) Comprova lamp seating and fixture connections |
| Lamp burns out quickly | Sobrevoltage Cicle d'encesa/apagada freqüent Touching glass with bare hands Poca ventilació | Assegureu-vos que el vol correctetage subministrament Minimize frequent switching Mànec lamp with gloves/cloth Assegureu-vos un flux d'aire adequat al voltant de lamp |
7. Consells d'usuari
- Manejar amb cura: Halògen lamps are delicate. Always handle them by the base or with a clean cloth/gloves to avoid damage and contamination.
- Verificar la compatibilitat: Before purchase and installation, double-check that the lamp's voltage, vatage, and base type (GZ6.35) are compatible with your specific equipment.
- Eliminació adequada: En substituir la lamp, dispose of the old bulb responsibly according to local environmental regulations.
- Avoid Over-Voltage: Funcionament de lamp en un voltage higher than its rated 12V can significantly shorten its lifespan.
8. Garantia i Suport
For any questions regarding the EYE JCR12V100W10H/G1/IR lamp, including technical support or warranty inquiries, please contact your original point of purchase or the manufacturer's authorized distributor. Keep your purchase receipt as proof of purchase.