APC AP9562

Manual d'usuari de la PDU de muntatge en rack d'APC

Model: AP9562

Introducció

This manual provides essential information for the safe and efficient use of your APC Rack Mount PDU, Basic 100V-120V/15A, with 10 outlets and 1U horizontal rackmount design (Model AP9562). This Power Distribution Unit is designed to provide reliable power distribution to equipment within a rack environment.

For a complete PDF version of this manual, please refer to the Manual d'usuari oficial (PDF).

Informació de seguretat

Observeu sempre les precaucions de seguretat següents:

Contingut del paquet

Verifiqueu que tots els components siguin presents:

Configuració i instal·lació

The APC Rack Mount PDU (AP9562) is designed for 1U horizontal mounting within a standard 19-inch rack.

Muntatge de la PDU

  1. Identify an available 1U space in your rack.
  2. Attach the provided rack mounting brackets to the PDU using the included screws. Ensure they are securely fastened.
  3. Align the PDU with the rack posts and secure it using appropriate rack screws (not included).
APC Rack Mount PDU, front view showing 10 outlets and power cord

Figura 1: Frontal view of the APC Rack Mount PDU (AP9562) showing the 10 NEMA 5-15R outlets and the attached power cord on the left side.

Potència de connexió

  1. Ensure all equipment to be connected is powered off.
  2. Connect the PDU's integrated 11.8-foot power cord (NEMA 5-15P) to a dedicated 100V-120V/15A power source.
  3. Connect your rack-mounted equipment's power cords to the 10 available NEMA 5-15R outlets on the PDU.
  4. Verify all connections are secure before powering on equipment.

Instruccions de funcionament

The APC Rack Mount PDU (AP9562) is a basic power distribution unit. It does not feature individual outlet switching or advanced monitoring capabilities. Power is continuously supplied to all outlets when the unit is connected to a live power source.

Powering On/Off Connected Equipment

To power on or off equipment connected to the PDU, use the power switches or controls on the individual equipment units. The PDU itself does not have a master power switch for all outlets.

Protecció de sobrecàrrega

The PDU is equipped with a 15A circuit breaker. In the event of an overload (total current draw exceeding 15A), the circuit breaker will trip to protect connected equipment and the PDU. If this occurs:

  1. Disconnect some equipment to reduce the load.
  2. Wait a few moments for the breaker to cool.
  3. Press the circuit breaker reset button (typically located near the power cord input) to restore power.

Manteniment

The APC Rack Mount PDU (AP9562) requires minimal maintenance. Follow these guidelines to ensure optimal performance and longevity:

Resolució de problemes

ProblemaCausa possibleSolució
No power from PDU outlets.PDU power cord is disconnected or not fully inserted.Ensure the PDU's power cord is securely plugged into a live power source.
Circuit breaker has tripped due to overload.Reduce the total load by disconnecting some equipment, then reset the circuit breaker.
Power source issue (e.g., wall outlet not working).Test the power source with another device to confirm it is supplying power.
Equipment not powering on when connected to PDU.Equipment's own power switch is off.Ensure the power switch on the connected equipment is in the 'On' position.
Faulty equipment power cord.Try a different power cord for the equipment.

If the problem persists after attempting these solutions, contact APC customer support for further assistance.

Especificacions

CaracterísticaDetall
Número de modelAP9562
Entrada Voltage100V-120V
Corrent d'entrada (màx.)15A
Connexió d'entradaNEMA 5-15P
Receptacles de sortida10 x NEMA 5-15R
Factor de forma1U Horizontal Rackmount
Longitud del cable11.8 peus (3.6 metres)
Dimensions del producte (A x A x P)1.73 x 17.6 x 2.24 polzades (4.4 x 44.7 x 5.7 cm)
Pes de l'article5.05 lliures (2.29 kg)
FabricantAPC

Informació de la garantia

APC products typically come with a standard manufacturer's warranty. For specific warranty terms and conditions applicable to your AP9562 PDU, please refer to the warranty card included with your product or visit the official APC weblloc web. Conserveu el comprovant de compra per a reclamacions de garantia.

Atenció al client

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact APC customer support:

When contacting support, please have your product model number (AP9562) and serial number ready.

Documents relacionats - AP9562

Preview APC Switched Rack Power Distribution Unit Installation Guide
Installation and operation guide for APC Switched Rack Power Distribution Units (PDUs), covering features, installation, configuration, access, warranty, and support.
Preview Guia d'instal·lació de substitució de la PDU APC SMT2200/SMT3000 | Schneider Electric
Aquesta guia proporciona instruccions per instal·lar un panell PDU de recanvi opcional per als sistemes UPS APC SMT2200 i SMT3000. Inclou missatges de seguretat importants, directrius de manipulació del producte i procediments d'instal·lació pas a pas.
Preview Guia d’instal·lació de la unitat de distribució de potència en rack APC
Instruccions d'instal·lació per a les unitats de distribució d'alimentació (PDU) en rack d'APC, incloent-hi les precaucions de seguretat, els procediments de muntatge i la informació de la interfície de la pantalla.
Preview Manual d'instal·lació i usuari d'APC NetShelter AR1000, AR1001, AR1100
This manual provides detailed instructions for the installation, setup, and maintenance of American Power Conversion (APC) NetShelter rack enclosures, including models AR1000, AR1001, and AR1100. It covers product inventory, warnings, configuration, leveling, stabilization, and warranty information.
Preview Guia de productes de sistemes de rack i PDU avançats d'APC NetShelter Rack
Comprehensive guide to APC NetShelter Rack PDUs, including the advanced 4-in-1 outlet models, basic, metered, switched, and metered-by-outlet options for data center power management. Features specifications, accessories, and rack system solutions.
Preview Guia d'instal·lació d'APC Smart-UPS: de SMT750RMI2UC a SMT3000RMI2UC
Aquesta guia proporciona instruccions d'instal·lació per als models SAI Smart d'APC SMT750RMI2UC, SMT1000RMI2UC, SMT1500RMI2UC, SMT2200RMI2UC i SMT3000RMI2UC. Cobreix el muntatge en bastidor, les connexions i la configuració de SmartConnect.