Intermatic E1020

Intermatic E1020 24-Hour Mechanical Timer User Manual

Model: E1020 | Brand: Intermatic

1. Producte acabatview

The Intermatic E1020 is a heavy-duty in-wall mechanical time switch designed for controlling lights, fans, pumps, and other heavy-duty electrical loads. It provides energy savings, enhanced security, and convenience by automating the operation of connected devices. This timer features a multiple program dial and is capable of accommodating up to 12 ON and 12 OFF trippers for precise scheduling.

Intermatic E1020 24-Hour Mechanical Timer

Figura 1: Frontal view of the Intermatic E1020 24-Hour Mechanical Timer, showing the dial and manual override switch.

2. Informació de seguretat

ADVERTIMENT: Risk of electric shock. Disconnect power at the circuit breaker or fuse box before installation or servicing. Installation should be performed by a qualified electrician or in accordance with local electrical codes.

For detailed safety guidelines and electrical diagrams, refer to the official installation manual: Intermatic E1020 Installation Manual (PDF).

3. Contingut del paquet

The Intermatic E1020 package typically includes:

4. Instal·lació

Follow these steps for proper installation of your Intermatic E1020 timer. It is highly recommended to consult the full installation manual for detailed diagrams and safety instructions.

Installation instructions for Intermatic E1020 timer

Figure 2: Diagram and text outlining the installation steps for the Intermatic E1020 timer.

Passos d'instal·lació:

  1. Desconnecteu l'energia elèctrica: For safety, disconnect your electrical power at the circuit breaker or fuse box before beginning installation.
  2. Remove Wall Plate and Disconnect Light Switch: Carefully remove the existing wall plate and disconnect the light switch. Ensure both "hot" (usually black or red) and "neutral" (usually white) wires are present in the junction box. If not, additional wiring may be necessary.
  3. Connect Timer Wires:
    • Connect the red timer wire to the wire from the fixture using a wire connector.
    • Connect the black timer wire to the "hot" wire in the junction box using a wire connector.
    • Cut the white wire in the junction box (or open splice) and strip 1/2 inch of insulation from both ends. Connect the white timer wire to the white wires in the junction box using a wire connector.
  4. Posada a terra: If the wall switch being replaced had separate grounding conductors connected to a GREEN screw, ensure these wires are now securely connected to the METAL wall box. If your box is non-metallic (plastic), the wires should be securely tied together.
  5. Connexions segures: Comproveu que totes les connexions dels cables estiguin segures.
  6. Fit Timer and Install: Place all wires inside the junction box. Fit the timer over the junction box first, ensuring all wires are neatly tucked and wire connectors are twisted behind the timer motor. NO FORÇAR. Next, install the timer using the provided mounting screws.
  7. Torneu a connectar l'alimentació: Reconnect your electrical power. Proceed to set the timer as per the operating instructions.

5. Configuració i programació

The E1020 timer uses a 24-hour dial with movable trippers to set ON and OFF times. The dial rotates clockwise, completing one full rotation every 24 hours.

Configuració de l'hora actual:

Rotate the outer dial clockwise until the current time aligns with the arrow indicator located on the stationary part of the timer. The dial is marked with AM and PM hours. For example, if it's 3 PM, align '3 PM' with the arrow.

Programació dels horaris d'encesa/apagada:

The timer comes with two ON trippers (gold/brass colored) and two OFF trippers (silver colored). Additional trippers can be purchased if needed, up to a maximum of 12 ON and 12 OFF trippers.

  1. Install Trippers: Locate the small slots around the edge of the dial. Insert the trippers into these slots at the desired ON and OFF times. The ON trippers will activate the connected device, and the OFF trippers will deactivate it. Ensure they are firmly seated.
  2. Adjust Trippers: Trippers can be easily moved by hand to adjust the program schedule. Each segment on the dial represents a specific time interval.
  3. Verify Program: Once trippers are set, manually rotate the dial through a full 24-hour cycle to observe the trippers engaging the internal mechanism, ensuring they are set correctly for your desired schedule.

Nota: There are no official seller videos available for this product demonstrating the setup process. However, customer-submitted videos often show the manual adjustment of the timer dial and trippers. For example, a video titled "Intermatic E1020 24-Hour 15-Amps Multiple Program Heavy Duty Mechanical Timer, Color" (ID: amzn1.vse.video.4215b5f1130a465fa5a0a92541536e25) illustrates a hand rotating the dial and adjusting the small white tabs (trippers) around the perimeter to set the desired on/off times. The video shows the audible click as the internal mechanism engages when the trippers pass the activation point.

6. Instruccions de funcionament

Once installed and programmed, the Intermatic E1020 timer operates automatically according to the set ON and OFF times. The dial continuously rotates, activating and deactivating the connected load as the trippers engage the internal switch.

Anulació manual:

The timer is equipped with an easy-to-use manual override switch (on/off toggle) located on the side of the unit. This allows you to manually turn the connected device ON or OFF, overriding the programmed schedule without affecting the timer's internal clock or program settings. Simply toggle the switch to the desired position.

7. Manteniment

The Intermatic E1020 mechanical timer requires minimal maintenance. To ensure optimal performance and longevity:

8. Solució De Problemes

If you encounter issues with your Intermatic E1020 timer, consider the following:

ProblemaCausa possibleSolució
El dispositiu no s'encén/apaga a les hores programades.
  • Trippers incorrectly placed or loose.
  • L'hora actual no està configurada correctament.
  • Problema d'alimentació.
  • Ensure ON/OFF trippers are firmly inserted at the correct times.
  • Verify the current time on the dial aligns with the indicator arrow.
  • Comproveu el disjuntor i les connexions del cablejat.
Timer makes a loud ticking or grinding noise.
  • Normal operation for mechanical timers (some noise is expected).
  • Internal mechanism wear (especially in older units).
  • A slight ticking sound is normal.
  • If the noise is excessive or new, the unit may be nearing the end of its lifespan. Consider replacement if the noise is disruptive or if the timer's function is affected.
Manual override switch does not work.
  • Mal funcionament de l'interruptor intern.
  • If the manual override fails, the unit may require replacement.

If problems persist after attempting these solutions, contact Intermatic customer support or consult a qualified electrician.

9. Especificacions

CaracterísticaDetall
Número de modelE1020
MarcaIntermatic
TipusTemporitzador mecànic de 24 hores
Voltage125 Volts
Wattage1500 watts
Ampedat15 Amps (implied by wattage / voltage)
MaterialPlàstic
Dimensions del producte (P x A x A)1.38 "P x 3.25" W x 4.25" H
Pes de l'article0.74 lliures (aproximadament 11.8 unces)
Nombre de configuracionsAccommodates up to 12 ON and 12 OFF trippers
Tipus de muntatgeMuntatge de paret
Estil de commutacióToggle Switch (for manual override)
CertificacióCSA

10. Garantia i Suport

Garantia: The Intermatic E1020 comes with a 1-year warranty. This warranty typically covers replacement of the unit but does not include labor costs for removal or reinstallation.

For warranty claims, technical assistance, or further inquiries, please contact Intermatic customer support directly. Refer to the official Intermatic weblloc web per obtenir la informació de contacte més actualitzada.

També podeu trobar recursos addicionals i informació sobre el producte a Botiga Intermatic a Amazon.

Documents relacionats - E1020

Preview Temporitzador automàtic de paret Intermatic E-1020 de 24 hores: Guia d'instal·lació i funcionament
Guia completa per a la instal·lació i el funcionament del temporitzador de programa múltiple automàtic de 24 hores Intermatic E-1020 per a la paret. Inclou instruccions pas a pas, diagrames de cablejat i detalls de la garantia.
Preview Com instal·lar i fer funcionar el temporitzador de paret de 24 hores Intermatic E-1020
Guia completa per a la instal·lació i el funcionament del temporitzador mecànic de paret Intermatic E-1020 de 24 hores amb programa múltiple. Inclou instruccions de cablejat, passos de programació i informació sobre la garantia.
Preview Manual d'usuari i garantia del temporitzador Intermatic TN311
Guia d'usuari i informació sobre la garantia limitada d'un any per al temporitzador de presa de corrent amb connexió a terra Intermatic TN311. Apreneu a configurar el programa, l'hora del dia i la anul·lació automàtica.
Preview Interruptor horari de marcatge de 24 hores Intermatic T105: guia d'instal·lació, cablejat i funcionament
Guia completa per a l'interruptor temporitzador mecànic de 24 hores Intermatic T105. Cobreix les especificacions del model, els avisos de seguretat, les instruccions de cablejat per a diverses configuracions (SPNO, SPNC, SPDT), els procediments de programació i el funcionament manual. Inclou una taula detallada de les classificacions elèctriques i les recomanacions de calibre de cable.
Preview Temporitzador digital de 7 dies per a exteriors Intermatic HB880R: instruccions d'ús i guia de configuració
Manual d'usuari complet per al temporitzador digital de 7 dies per a exteriors Intermatic HB880R. Apreneu a instal·lar, programar, configurar horaris i solucionar problemes d'aquest interruptor horari versàtil.
Preview Guia d'instal·lació i funcionament del temporitzador de paret de 24 hores Intermatic E-1010
Instruccions detallades per instal·lar i fer funcionar el temporitzador automàtic de paret Intermatic E-1010 de 24 hores. Cobreix el cablejat, el funcionament manual, la configuració automàtica i la informació de garantia per a ús residencial.