Introducció
This manual provides comprehensive instructions for the safe installation, operation, and maintenance of the Lewmar 68000348 50 Amp Thermal Circuit Breaker. This device is specifically designed for use in marine electrical systems, particularly with Lewmar electric winches and windlasses, to protect circuits from overcurrent conditions.
Informació de seguretat
WARNING: Electrical shock hazard. Always disconnect power before installation or servicing.
- Ensure all power sources are disconnected before beginning installation or maintenance.
- Installation should be performed by a qualified marine electrician or technician.
- Verify the circuit breaker's current rating (50 Amps) matches the requirements of the protected circuit.
- No feu funcionar l'interruptor si sembla que està danyat.
- This device is designed for DC applications up to 48 Volts.
Producte acabatview
The Lewmar 68000348 is a 50 Amp thermal circuit breaker designed for panel mounting. It features an automatic trip mechanism in response to overcurrent and a manual reset button. Its robust, waterproof design ensures reliable performance in marine environments.
Components clau
- Circuit Breaker Body: The main housing containing the electrical components.
- Botó de restabliment: A red button used to manually reset the breaker after it has tripped.
- Forats de muntatge: Holes for securing the breaker to a panel.
- Terminals elèctrics: Connections for input and output wiring.
Imatge del producte

Figura 1: Frontal view of the Lewmar 68000348 50 Amp Thermal Circuit Breaker, showing the 50 Amp rating, thermal circuit breaker designation, 48 Volts DC maximum, ignition protected, waterproof labels, and the red reset button with a yellow reset lever.
Configuració i instal·lació
Proper installation is crucial for the safe and effective operation of the circuit breaker. Follow these steps carefully:
- Seleccioneu la ubicació de muntatge: Choose a dry, accessible location on a panel, away from excessive heat or vibration. Ensure sufficient space for wiring and access to the reset button.
- Preparació de la superfície de muntatge: Drill appropriate holes for mounting screws and the breaker body, if recess mounting. Refer to the product dimensions for precise measurements (6 x 6 x 6 inches).
- Mount the Breaker: Secure the circuit breaker to the panel using appropriate fasteners through the mounting holes.
- Connexions de cable: Connect the positive (+) input wire from the power source to one terminal and the positive (+) output wire to the protected device (e.g., winch, windlass) to the other terminal. Ensure all connections are tight and secure. This is a 2-pole breaker.
- Verifiqueu el cablejat: Double-check all wiring connections for correctness and polarity before restoring power.
- Restaura l'alimentació: Un cop finalitzada i verificada la instal·lació, restableix l'alimentació del circuit.
Instruccions de funcionament
The Lewmar 68000348 circuit breaker operates automatically to protect your electrical system:
- Funcionament normal: Under normal conditions, current flows through the breaker without interruption.
- Overcurrent Trip: Si el corrent supera els 50 Amps due to an overload or short circuit, the thermal mechanism within the breaker will heat up and automatically trip, interrupting the circuit. The red reset button will typically pop out.
- Resetting the Breaker: To reset the breaker after a trip, first identify and rectify the cause of the overcurrent (e.g., remove the overload, fix the short circuit). Once the issue is resolved, firmly press the red reset button until it clicks back into place. If the breaker immediately trips again, the fault has not been cleared.
Manteniment
The Lewmar 68000348 circuit breaker requires minimal maintenance:
- Inspecció periòdica: Regularly inspect the breaker and its connections for any signs of corrosion, loose wiring, or physical damage.
- Neteja: Keep the breaker clean and free of dirt, dust, and moisture. Use a dry cloth for cleaning.
- Comprovació del terminal: Periodically check the tightness of the electrical terminal connections.
Resolució de problemes
Consulteu la taula següent per veure els problemes habituals i les seves possibles solucions:
| Problema | Causa possible | Solució |
|---|---|---|
| L'interruptor es dispara immediatament després del reinici. | Sobrecàrrega o curtcircuit persistent en el circuit protegit. | Identify and resolve the underlying electrical fault. Do not repeatedly reset the breaker without addressing the cause. |
| Breaker does not trip under overload. | Breaker is faulty or undersized for the application. | Replace the breaker. Ensure the correct amperage rating is used for the circuit. |
| No power to device, breaker not tripped. | Loose connections, faulty wiring, or power source issue. | Check all wiring connections for tightness. Verify power supply to the breaker. Inspect wiring for damage. |
| Physical damage to breaker. | Impacte o manipulació inadequada. | Replace the damaged breaker immediately. |
Especificacions
| Característica | Detall |
|---|---|
| Número de model | 68000348 |
| Fabricant | Lewmar |
| Valoració actual | 50 Amps |
| Tipus d'interruptor | Thermal, Standard |
| Tipus de muntatge | Suport al tauler |
| Nombre de pols | 2 |
| Volum màximtage | 48 Volts DC |
| Característiques de protecció | Ignition Protected, Waterproof |
| Pes de l'article | 2.4 unces |
| Dimensions del producte | 6 x 6 x 6 polzades |
| UPC | 743683305719 |
Informació de la garantia
For detailed warranty information regarding the Lewmar 68000348 50 Amp Thermal Circuit Breaker, please refer to the documentation provided with your purchase or contact Lewmar directly. Warranty terms and conditions may vary.
Atenció al client
If you require further assistance, technical support, or have questions not covered in this manual, please contact Lewmar customer service or visit their official weblloc de recursos de suport.