This instruction manual provides essential information for the safe and effective use, installation, and maintenance of your FIRST ALERT PRO5 Rechargeable Heavy Duty Fire Extinguisher. This extinguisher is UL rated 3-A:40-B:C and is designed to combat various types of fires, including those involving wood, paper, fabric, flammable liquids, and live electrical equipment.
ADVERTÈNCIA: Aquest producte conté substàncies químiques que l'estat de Califòrnia sap que causen càncer i defectes congènits o altres danys reproductius. Per a més informació, visiteu www.P65Warnings.ca.gov.
Informació de seguretat
Always prioritize safety when handling fire extinguishing equipment. Read and understand all instructions before use.
- Ensure the pressure gauge is in the green area before use. If the needle is in the red area, the extinguisher is not adequately pressurized and must be recharged by a certified professional.
- Do not break the safety seal until ready for immediate use.
- Store the extinguisher in a dry place where the temperature does not go above 120°F (49°C) or below -40°F (-40°C).
- Mantenir fora de l'abast dels nens petits.
Configuració i instal·lació
Proper placement and installation are crucial for quick access during an emergency.
Ubicació recomanada:
- Near a potential source of heat (e.g., kitchen, garage, workshop).
- In a location that is easy to reach, near an exit, or an escape route from the room.
- Mount the extinguisher high enough to keep it out of the reach of small children, typically 3-1/2 to 5 feet (1 to 1.5 meters) above the floor.
Mounting the Extinguisher:
The FIRST ALERT PRO5 Fire Extinguisher comes with a mounting bracket for secure placement. Follow these steps to install it:
- Select a sturdy surface (wood stud or plaster with wood support) that can support the weight of the extinguisher.
- Install the mounting bracket using appropriate screws (not included). Ensure the bracket is firmly secured to the wall.
- After installing the mounting bracket, place the extinguisher into the bracket. The bracket features a strap that wraps around the cylinder to hold it securely. Snap the buckle to secure the extinguisher in place.

Image: The First Alert PRO5 Fire Extinguisher with its mounting bracket.

Image: Key features of the PRO5 extinguisher, including its commercial grade metal valve and rechargeable compliance unit.
Instruccions de funcionament
In the event of a fire, remember the P.A.S.S. method:
- Pull the pin: Break the safety seal and pull the pin from the handle.
- Aim at the base of the fire: Stand back approximately 6 feet (1.8 meters) from the fire.
- Squeeze the lever: Depress the operating lever to discharge the extinguishing agent.
- Sweep from side to side: Move the nozzle from side to side, aiming at the base of the fire until it is extinguished.

Image: A family discussing fire safety, emphasizing the importance of preparedness.
Manteniment
Regular inspection and proper maintenance ensure your fire extinguisher is ready when needed.
- Comprovar la pressió: Inspect the pressure gauge monthly. The needle should always be in the green "CHARGE" area. If it's in the red "RECHARGE" or "OVERCHARGE" area, the extinguisher needs professional servicing.
- Neteja: Keep the extinguisher clean and free from obstructions. Wipe down the exterior with a damp tela si cal.
- Recarregabilitat: This extinguisher is rechargeable by certified professionals after use. Do not attempt to refill it yourself.
- Safety Seal: Assegureu-vos que tamper indicator (safety seal) is intact. If it's broken or missing, the extinguisher may have been tampered with or discharged and should be inspected.
Resolució de problemes
If your fire extinguisher is not functioning as expected, consider the following:
- Sense pressió: If the pressure gauge needle is in the red "RECHARGE" area, the extinguisher has lost pressure and will not operate effectively. It must be recharged by a certified professional.
- Components danyats: If the nozzle, hose, or operating lever appears damaged, do not attempt to use the extinguisher. Contact a certified professional for inspection or replacement.
- Accidental Discharge: If the safety pin is removed and the lever is accidentally squeezed, even briefly, the extinguisher will gradually lose pressure. It must be recharged.
Especificacions
| Atribut | Detall |
|---|---|
| Marca | PRIMERA ALERTA |
| Model | PRO5 (1039896) |
| Classificació UL | 3-A:40-B:C |
| Agent extintor | Mono Ammonium Phosphate |
| Material | Metall |
| Color | Vermell |
| Dimensions del producte | 4.8 "P x 6" W x 16.2" H |
| Pes de l'article | 9 lliures |
| Font d'alimentació | ac_dc (Not applicable for operation, refers to general product category) |
| Certificació | not_applicable (UL Rated) |
Garantia i Suport
Informació de la garantia:
The FIRST ALERT PRO5 Fire Extinguisher comes with a Garantia limitada d'12 any. Please refer to the warranty card included with your purchase for full terms and conditions.

Image: Visual representation of the 12-year limited warranty for the First Alert PRO5 Fire Extinguisher.
Atenció al client:
For further assistance, technical support, or to inquire about recharging services, please contact First Alert customer service. Refer to the product packaging or the official First Alert weblloc per obtenir dades de contacte.
També podeu visitar l'oficial First Alert Store on Amazon per a més informació i productes.