Intermatic ET8215C Astronomic Electronic Time Switch User Manual

Model: ET8215C | Brand: Intermatic

1. Producte acabatview

The Intermatic ET8215C Astronomic Electronic Time Switch is designed for automated weekly scheduling of electrical loads. It features multi-volt operation, precise to-the-minute programming, and an astronomic function that automatically adjusts ON/OFF times based on local sunrise and sunset. This 2-circuit, 30-Amp time switch is housed in a durable Type 1 steel enclosure, providing reliable control for various lighting and electrical applications.

Intermatic ET8215C Astronomic Electronic Time Switch, front view

Figura 1: Frontal view of the Intermatic ET8215C Astronomic Electronic Time Switch with the cover open, showing the display and control buttons.

Característiques principals:

2. Informació de seguretat

ADVERTÈNCIA: Risc de descàrrega elèctrica. More than one disconnect switch may be required to de-energize the equipment before servicing. Installation and servicing should only be performed by qualified personnel. Always disconnect power at the circuit breaker or fuse box before installing or servicing this device.

3. Contingut del paquet

Verifiqueu que tots els components siguin presents abans de començar la instal·lació:

4. Configuració i instal·lació

4.1 Muntatge de la carcassa

The ET8215C is designed for NEMA 1 indoor applications. Choose a suitable location that is dry, protected from extreme temperatures, and allows for easy access for wiring and programming. Secure the steel enclosure to a flat, stable surface using appropriate mounting hardware (not included).

Intermatic ET8215C Astronomic Electronic Time Switch, closed cover

Figure 2: The Intermatic ET8215C with its steel enclosure cover closed.

4.2 Instruccions de cablejat

The ET8215C supports multi-volt operation (120-277 VAC) and can be configured for two independently operated SPST circuits, one simultaneous operated DPST, or independently pulsed SPST for contactor and bell ringing applications. Refer to the internal wiring diagram and the following guidelines:

  1. Desconnecteu l'alimentació: Ensure all power to the circuit is OFF at the main breaker before proceeding.
  2. Recinte obert: Open the front cover of the time switch to access the wiring terminals and internal components.
  3. Seleccioneu Voltage: Localitza el voltage selection switch inside the unit. Set it to the correct voltage (120V, 208V, 240V, or 277V) corresponding to your electrical supply.
  4. Primer pla del volumtage selection switch inside the Intermatic ET8215C

    Figura 3: Primer pla view of the internal voltage interruptor de selecció.

  5. Connecteu el cablejat: Follow the wiring diagram printed inside the enclosure. The terminals are typically labeled for Timer Power (1, 2), Line 1 (3), Load 1 (4), Line 2 (5), and Load 2 (6).
  6. Interna view of Intermatic ET8215C showing wiring diagram and terminals

    Figura 4: Intern view showing the wiring diagram, terminals, and display.

  7. Connexions segures: Assegureu-vos que totes les connexions dels cables estiguin ajustades i segures.
  8. Tancament tancat: Once wiring is complete and verified, close the front cover securely.

4.3 Initial Power-up and Battery Installation

The unit requires 2 AAA batteries for memory backup and initial setup. These are typically included. If not already installed, open the battery compartment and insert the batteries, observing correct polarity.

Close-up of the battery compartment and control buttons on the Intermatic ET8215C

Figura 5: Primer pla view of the battery compartment and control buttons.

After wiring and battery installation, restore power to the circuit. The display should illuminate, and the unit will be ready for programming.

5. Instruccions de funcionament

The ET8215C is programmed using the buttons located below the display. The primary buttons are MODE, DIA, RESET, ENTER NEXT, +, -, i ON/OFF.

5.1 Configuració de la data i l'hora actuals

  1. Premeu el botó MODE button repeatedly until the clock icon appears on the display.
  2. Utilitza el + or - botons per ajustar l'hora i, a continuació, premeu ENTER NEXT.
  3. Repeat for minutes, AM/PM, year, month, and day.
  4. Premeu ENTER NEXT per guardar i sortir.

5.2 Programació d'esdeveniments ON/OFF

The time switch allows for up to 28 ON/OFF events. Each event can be programmed for specific days of the week or daily.

  1. Premeu el botó MODE button repeatedly until 'PROG' appears on the display.
  2. The display will show 'ON 1'. Use + or - to select the desired event number (1-28).
  3. Premeu ENTER NEXT. Ús DIA to select the day(s) for this event (e.g., MO, TU, WE, TH, FR, SA, SU, or ALL DAYS).
  4. Premeu ENTER NEXT. Ús + or - to set the ON time for the event.
  5. Premeu ENTER NEXT. The display will show 'OFF 1'. Use + or - to set the OFF time for the event.
  6. Premeu ENTER NEXT to save the event. Repeat for additional events.

5.3 Using the Astronomic Feature

The astronomic feature allows the time switch to automatically adjust ON/OFF times based on local sunrise and sunset. This eliminates the need for manual adjustments due to seasonal changes.

  1. Premeu el botó MODE button repeatedly until 'ASTRO' appears on the display.
  2. Ús + or - to set your geographical location (e.g., by entering your latitude/longitude or a pre-defined zone). Refer to the full manual for detailed location setup.
  3. When programming an event, you can select 'SUNRISE' or 'SUNSET' instead of a specific time for the ON or OFF event.
  4. You can also set an offset (e.g., 15 minutes before sunset) if desired.

5.4 Anulació manual

To manually turn the load ON or OFF, press the ON/OFF button. This will temporarily override the programmed schedule until the next scheduled event occurs.

6. Manteniment

The Intermatic ET8215C is designed for minimal maintenance. The primary maintenance task is battery replacement.

6.1 Substitució de la bateria

The unit uses 2 AAA alkaline batteries for memory backup. If the display becomes dim or the unit loses its programming during a power outage, the batteries may need replacement. It is recommended to replace batteries every 3-5 years, or as needed.

  1. Desconnecteu l'alimentació: For safety, turn off power to the time switch at the circuit breaker.
  2. Recinte obert: Open the front cover of the time switch.
  3. Traieu les piles velles: Locate the battery compartment and remove the old AAA batteries.
  4. Instal·leu piles noves: Introduïu dues piles alcalines AAA noves, assegurant-vos de la polaritat correcta (+/-).
  5. Tancament tancat: Tanqueu la coberta frontal de manera segura.
  6. Restaura l'alimentació: Torneu a encendre l'alimentació al disjuntor.

7. Solució De Problemes

This section addresses common issues you might encounter with your ET8215C time switch.

ProblemaCausa possibleSolució
La pantalla està en blanc o tènue.No power to the unit or dead batteries.Check circuit breaker. Ensure unit is wired correctly. Replace AAA batteries.
Unit does not switch loads ON/OFF at programmed times.Incorrect programming, manual override active, or wiring issue.Review programming steps carefully. Check if manual override is active. Verify load wiring connections.
Astronomic feature not working correctly.Incorrect location setting.Ensure the correct geographical location (latitude/longitude or zone) is entered in the astronomic settings.
Difficulty with initial programming.Desconeixement de la seqüència de botons.Carefully follow the programming steps in Section 5. Practice the sequence without connecting loads if necessary.
Wiring seems confusing.Complex electrical setup or unclear diagram interpretation.Consult a qualified electrician for assistance with wiring. Refer to the internal wiring diagram and ensure all connections match your specific application.

If problems persist after attempting these solutions, contact Intermatic customer support.

8. Especificacions

Número de modelET8215C
Voltage120-277 VAC, 50 / 60 Hz
Circuits2-Circuit
AmpErage Rating30-Amp
Tipus de tancamentTancament d'acer tipus 1
Dimensions (A x A x P)7.75" x 5" x 3"
MaterialAcer d'aliatge
ColorGris
Tipus de bateria2 piles alcalines AAA (incloses)
Estil de commutacióSPST/DPST
AprovacionsCSA (Canada and US)
UPC078275089761

9. Garantia i Suport

9.1 Informació de la garantia

This Intermatic ET8215C Astronomic Electronic Time Switch comes with a Garantia limitada d'1 any. The warranty covers replacement of the unit due to manufacturing defects. It does not cover labor costs associated with removal or reinstallation of the unit.

9.2 Atenció al client

For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact Intermatic customer support directly. Refer to the official Intermatic weblloc web o l'embalatge del producte per obtenir la informació de contacte més actualitzada.

També podeu visitar el Botiga Intermatic a Amazon per obtenir més informació sobre el producte i recursos.

Documents relacionats - ET8215C

Preview Intermatic sèrie ET8000 Intermatic Intermatic Interlock astronòmic electrònic de 7 dies: instruccions d'instal·lació i ús
Guia completa d'instal·lació i ús del commutador horari astronòmic electrònic de 7 dies Intermatic sèrie ET8000, que detalla les característiques, les especificacions, el cablejat, la programació i el manteniment.
Preview Intermatic sèrie ET8000 Intermatic Intermatic Interlock astronòmic electrònic de 7 dies: instruccions d'instal·lació i ús
Comprehensive installation and user guide for the Intermatic ET8000 Series Electronic Astronomic 7-Day Time Switch. Learn about its features, programming, and specifications for efficient load control.
Preview Control temporitzador electrònic Intermatic ET8215C - Dades tècniques
Especificacions tècniques detallades per al control temporitzador electrònic Intermatic ET8215C, un control electrònic astronòmic de 7 dies i 2 circuits adequat per a aplicacions de 120-277 VAC en una carcassa metàl·lica interior.
Preview Intermatic ET8000 Series Electronic Astronomic 7-Day Time Switch Owner/Installer Instruction Manual
This manual provides comprehensive instructions for the Intermatic ET8000 Series Electronic Astronomic 7-Day Time Switch. It covers essential specifications, detailed installation procedures, programming steps for astronomic and fixed events, wiring diagrams for various models (ET8015C, ET8115C, ET8215C), general safety information, and a one-year limited warranty. The time switch offers flexible 7-day scheduling with up to 224 set points, automatic sunset/sunrise adjustments, and battery carryover for continuous operation.
Preview Guia d'instal·lació i configuració del commutador horari astronòmic electrònic de 7 dies d'1 circuit Intermatic ET2805C/CR/CP
Manual detallat d'instal·lació i configuració dels interruptors horaris astronòmics de 7 dies Intermatic ET2805C, ET2805CR, ET2805CP. Cobreix la programació, la programació, l'horari d'estiu i les funcions operatives per al control automatitzat de la càrrega.
Preview Guia d'instal·lació i configuració del commutador horari astronòmic electrònic de 7 dies Intermatic ET2805C/CR/CP
Guia completa d'instal·lació, configuració i programació dels interruptors horaris astronòmics electrònics de 7 dies d'1 circuit Intermatic ET2805C, ET2805CR i ET2805CP, que inclou el cablejat, la programació i les especificacions.