Zoeller N145

Zoeller N145 Sump & Effluent Pump User Manual

Model: N145 | Part Number: 145-0002

1. Producte acabatview

The Zoeller "Flow-Mate" Sump & Effluent Pump, Model N145, is designed for residential or light commercial applications, including groundwater, septic tank, low pressure pipe (LPP), and enhanced flow STEP systems. This durable cast iron submersible pump features a powder-coated epoxy finish for corrosion prevention and is engineered for efficient heat dissipation, ensuring a long service life. Each unit undergoes rigorous testing to guarantee quality and reliability.

Zoeller N145 Sump and Effluent Pump

Figure 1: Zoeller N145 Sump & Effluent Pump. This image shows the green, cast iron pump unit with its electrical cord and discharge outlet.

Característiques principals:

2. Informació de seguretat

Always disconnect power before servicing or installing the pump. Ensure proper grounding to prevent electrical shock. Do not operate the pump dry. Refer to local codes and regulations for installation requirements. This pump is designed for water and effluent only; do not use for flammable or corrosive liquids.

3. Configuració i instal·lació

  1. Desembalatge: Carefully remove the pump from its packaging. Inspect for any shipping damage.
  2. Ubicació: Place the pump in a sump pit or basin that is clean and free of debris. Ensure the pit is large enough to allow the float switch (if applicable) to operate freely without obstruction.
  3. Tubs de descàrrega: Connect 1½" NPT discharge piping to the pump outlet. Use a check valve in the discharge line to prevent backflow of water into the pit. Ensure all connections are watertight.
  4. Connexió elèctrica: Connect the pump to a dedicated, properly grounded 115 Volt, 60 Hz electrical circuit. The circuit should be protected by a ground fault circuit interrupter (GFCI). Do not remove the ground pin from the plug.
  5. Float Switch (if applicable): If using an external float switch, ensure it is positioned to activate and deactivate the pump at desired water levels. Test its operation before final installation.
  6. Ventilació: Ensure the sump pit is adequately vented according to local plumbing codes.

4. Instruccions de funcionament

  1. Posada en marxa inicial: After installation, ensure the pump is fully submerged in water. Plug the pump into the grounded outlet.
  2. Funcionament automàtic: For models with an automatic float switch, the pump will activate when the water level rises to the "on" level and deactivate when it drops to the "off" level.
  3. Funcionament manual: For manual models, the pump will run continuously when plugged in. Monitor water levels to prevent dry running.
  4. Prova: Periodically test the pump by filling the sump pit with water to ensure it activates and pumps out water correctly.

Opcions del tauler de control:

This pump can be used with the following control panels:

5. Manteniment

Un manteniment regular garanteix un rendiment òptim i allarga la vida útil de la bomba.

6. Solució De Problemes

ProblemaCausa possibleSolució
La bomba no funciona.No power; tripped circuit breaker/GFCI; faulty float switch; motor overload.Check power supply; reset breaker/GFCI; inspect/replace float switch; allow motor to cool and reset.
La bomba funciona però no bomba aigua.Clogged impeller; air lock; discharge line blockage; low water level.Disconnect power and clear impeller; prime pump; clear discharge line; ensure adequate water level.
La bomba funciona contínuament.Interruptor de flotador encallat; fallada de la vàlvula antiretorn; entrada contínua d'aigua.Inspect/free float switch; replace check valve; identify and address source of continuous water.
La bomba circula amb massa freqüència.Sump pit too small; float switch set incorrectly; backflow from discharge line.Consider larger pit; adjust float switch settings; check/replace check valve.

7. Especificacions

AtributValor
MarcaZoeller
Número de modelN145
Número de part145-0002
Font d'alimentacióElèctric amb cable
Voltage115 Volts
Cavalls de força0.75 CV
Caudal màxim61 galons per minut (GPM)
Alçada màxima d'elevació (capçal)74 peus
Mida de descàrrega1½" NPT Vertical
Manipulació de sòlidsPasses ¾" spherical solids
Longitud del cable20 Feet (UL listed neoprene)
MaterialFerro colat
ColorVerd
Pes de l'articleApproximately 0.01 Ounces (Note: This weight seems incorrect based on typical pump weights, likely a data entry error in source. Actual weight would be significantly higher.)
Temperatura de funcionamentUp to 130°F (54°C) in effluent or dewatering applications
UPC053514213411

8. Garantia i Suport

For warranty information and technical support, please contact Zoeller directly or visit their official weblloc web. Conserveu el rebut de compra com a comprovant de compra per a reclamacions de garantia.

Zoeller Company Contact Information:

Documents relacionats - N145

Preview Sistemes de bombes de buidatge premuntades de la sèrie 900 de Zoeller: instal·lació fàcil
Descobreix els sistemes de bombes de buidatge premuntades de la sèrie 900 de Zoeller, dissenyades per a una instal·lació ràpida i senzilla. Les característiques inclouen un interruptor de flotador automàtic, una bomba de ferro colat resistent i diverses...asin opcions per a ús residencial i comercial. Més informació sobre les especificacions i el rendiment del model.
Preview Fitxa tècnica de les bombes submergibles de la sèrie Zoeller Mighty-Mate
Dades tècniques completes, especificacions, comparacions de models i corbes de rendiment per a les bombes submergibles d'efluents i deshidratació de la sèrie Zoeller Mighty-Mate, incloses les versions de ferro colat (models 53, 57) i bronze (models 55, 59).
Preview Fitxa tècnica de la bomba submergible Zoeller Mighty-Mate Series
Especificacions tècniques detallades, corbes de rendiment i comparació de models per a les bombes submergibles d'efluents i deshidratació de la sèrie Zoeller Mighty-Mate, inclosos els models de ferro colat 53, 57 i els models de bronze 55, 59.
Preview Sistemes d'alarma Zoeller APak: Monitorització de nivells alts d'aigua i bombes de buidatge
Coneix els sistemes d'alarma APak de Zoeller, inclosos els models d'interior i exterior amb funcions Z Control® per a notificacions fiables d'aigua alta, alertes d'avaria de la bomba i monitorització remota.
Preview Zoeller Models 63 & 95 Sump Pump Installation Instructions and Manual
Comprehensive installation instructions, pre-installation checklist, safety guidelines, troubleshooting, and limited warranty information for Zoeller Models 63 and 95 sump, effluent, and dewatering pumps.
Preview Zoeller Sump Pump Installation Guide: Models 53, 57, 98, 137, 151, 152, 153, 264, 266, 267, WD, WH
Comprehensive installation instructions, safety warnings, checklists, and troubleshooting guide for Zoeller sump, effluent, dewatering, and sewage pumps. Covers single-phase and three-phase models.