Crouse-Hinds LT400

Crouse-Hinds LT400 4-Inch Liquidtight Straight Connector Instruction Manual

Model: LT400 | Brand: Crouse-Hinds

Producte acabatview

The Crouse-Hinds LT400 is a 4-inch zinc electroplated malleable iron non-insulated liquidtight straight connector. This component is designed to securely connect liquidtight flexible metal conduit (LFMC) or liquidtight flexible non-metallic conduit (LFNC) to an electrical box or enclosure, providing a liquidtight and dust-tight seal. Its robust construction ensures durability and reliable performance in demanding environments.

Crouse-Hinds LT400 4-Inch Liquidtight Straight Connector

Figura 1: Illustration of the Crouse-Hinds LT400 4-inch liquidtight straight connector. This image displays the connector's threaded body, hexagonal nut for tightening, and the conduit entry point, highlighting its straight design for direct conduit connections.

Configuració i instal·lació

Proper installation of the LT400 connector is crucial for maintaining the integrity of the electrical system and ensuring a liquidtight seal. Follow these steps carefully:

  1. La seguretat primer: Ensure all power to the circuit is disconnected at the main service panel before beginning any electrical work. Use appropriate personal protective equipment (PPE).
  2. Prepare Conduit: Cut the liquidtight flexible conduit to the desired length. Ensure the cut is clean and free of burrs.
  3. Insert Conduit: Slide the conduit into the connector's entry point. Ensure the conduit jacket passes fully into the connector's sealing mechanism.
  4. Tighten Sealing Nut: Hand-tighten the sealing nut onto the connector body. Then, use a wrench to tighten it further, ensuring a firm grip on the conduit and a liquidtight seal. Do not overtighten, as this can damage the conduit or the connector.
  5. Attach to Enclosure: Insert the threaded end of the connector through the knockout hole in the electrical box or enclosure.
  6. Secure with Locknut: Thread the locknut onto the connector's threaded end from inside the enclosure. Hand-tighten, then use a wrench to secure it firmly against the enclosure wall.
  7. Verifica la connexió: Visually inspect all connections to ensure they are tight and properly seated.

Note: Always consult local electrical codes and standards for specific installation requirements.

Funcionalitat

Once installed, the Crouse-Hinds LT400 connector serves as a critical link in an electrical conduit system. Its primary function is to:

This connector is a passive component and does not require active operation after installation, beyond periodic inspection.

Manteniment

The Crouse-Hinds LT400 connector is designed for minimal maintenance. However, periodic inspection is recommended to ensure continued performance and safety:

Always ensure power is disconnected before performing any maintenance that involves touching electrical components.

Resolució de problemes

Should issues arise with the LT400 connector, consider the following:

Especificacions

AtributValor
Número de modelLT400
MarcaCrouse-Hinds
Mida4 polzades
MaterialZinc Electroplated Malleable Iron
Acabat exteriorZinc
ColorPlata
Tipus de filNPT
Pes de l'article7.35 lliures
Quantitat de paquet d'articles1
UPC784564304001
FabricantOEST MITJÀ

Informació de la garantia

Specific warranty details for the Crouse-Hinds LT400 connector are typically provided by the manufacturer at the time of purchase or can be found on the official Crouse-Hinds website. It is recommended to retain your proof of purchase for any warranty claims. For detailed warranty terms and conditions, please refer to the official documentation accompanying your product or contact Crouse-Hinds directly.

Suport

For technical assistance, product inquiries, or support regarding the Crouse-Hinds LT400 connector, please contact Crouse-Hinds customer service or visit their official website. Support resources may include FAQs, technical data sheets, and contact information for regional support teams.

Documents relacionats - LT400

Preview Paquet de bateries Crouse-Hinds sèrie NE+ per a ExLin NE+ Instruccions d'ús
Instruccions d'ús per al paquet de bateries Crouse-Hinds de la sèrie NE+, dissenyat per a lluminàries ExLin NE+. Cobreix dades tècniques, seguretat, funcionament, manteniment i instal·lació.
Preview CROUSE-HINDS XB15 Series Xenon Beacon - Hazardous Location Signalling
Datasheet for the CROUSE-HINDS XB15 series GRP xenon beacon, offering 5, 10, 15, and 21 joule options for hazardous and ordinary locations. Features ATEX, IECEx, UL, and INMETRO certifications, weatherproof design, and wide temperature range.
Preview Manual d'instruccions de la lluminària LED amb protecció contra explosions de la sèrie HFL
Manual d'instruccions per a la lluminària LED amb protecció contra explosions Crouse-Hinds sèrie HFL, que inclou dimensions, dades tècniques, instruccions de seguretat, conformitat amb les normes i pautes d'instal·lació.
Preview Crouse-Hinds TMC-K Series Corrosion Protection Kit Installation Guide
Detailed installation and maintenance information for Crouse-Hinds TMC-K Series Cold Shrink Corrosion Protection Kits, designed to protect electrical cable fittings from corrosive environments.
Preview CROUSE-HINDS SERIES eLLB 20.. V-CG-S Explosion Protected Recessed Ceiling Light Fittings - Operating Instructions
Comprehensive operating instructions, technical data, and installation guide for CROUSE-HINDS SERIES eLLB 20.. and eLLB 20.. V-CG-S explosion-protected recessed ceiling light fittings. Designed for hazardous areas, this document details safety, electrical specifications, wiring diagrams, mounting, maintenance, and V-CG-S module configuration.
Preview CROUSE-HINDS ExLin Explosion-Proof Luminaire - Operating Instructions and Technical Data
Comprehensive operating instructions, technical specifications, installation guides, and safety information for the CROUSE-HINDS ExLin and ExLin-L series of explosion-proof LED luminaires, including details on models, dimensions, type codes, wiring, technical data, and maintenance.