Honeywell MT200 T4360A1009

Honeywell MT200 T4360A1009 Frost Protection Room Thermostat User Manual

Model: MT200 T4360A1009

1. Introducció

The Honeywell MT200 T4360A1009 is a robust room thermostat designed primarily for frost protection. This device automatically safeguards your heating system, including boilers and pipework, against freezing temperatures. It is capable of directly switching a circulation pump or boiler to maintain a safe minimum temperature.

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Honeywell MT200 T4360A1009 thermostat.

2. Informació important de seguretat

  • Risc elèctric: Installation and wiring must be performed by a qualified electrician or competent person in accordance with all local and national electrical codes. Ensure the main power supply is disconnected before commencing any installation or maintenance work.
  • Live Terminals: The internal terminals of the thermostat carry live voltage. Do not remove the protective cover or attempt to adjust internal components while power is connected.
  • Ús previst: This thermostat is designed for frost protection and general room temperature control within its specified range. Do not use it for purposes other than its intended application.
  • Càrrega màxima: Do not exceed the specified maximum electrical load of 10 A resistive or 3 A inductive. Overloading can cause damage to the unit and create a fire hazard.

3. Contingut del paquet

Please check the package contents upon receipt. It should include:

  • Honeywell MT200 T4360A1009 Frost Protection Room Thermostat Unit
  • Funda protectora
  • Mounting Screws (may vary by region)

No batteries are required for the operation of this corded electric thermostat.

4. Instal·lació

The Honeywell MT200 T4360A1009 thermostat should be installed in a location that accurately reflects the room temperature and is not subject to direct sunlight, drafts, or heat sources. For optimal performance, mount the unit on an interior wall, approximately 1.5 meters (5 feet) from the floor.

4.1. Muntatge

  1. Desconnecteu l'alimentació: Ensure the main power supply to the heating system is switched off at the consumer unit/fuse box before proceeding.
  2. Traieu la coberta: Traieu amb cura la coberta frontal del termòstat per accedir als forats de muntatge i als terminals de cablejat.
  3. Posicionament: Hold the thermostat base against the wall at the desired mounting location. Mark the positions for the mounting screws.
  4. Forats: Drill pilot holes if necessary and insert wall plugs suitable for your wall type.
  5. Base segura: Fasten the thermostat base securely to the wall using the provided screws.

4.2. Cablatge

ADVERTIMENT: All wiring must comply with local electrical regulations and be carried out by a qualified professional.

  • Connect the electrical supply wires to the appropriate terminals as indicated in the wiring diagram provided with your unit (refer to the diagram on the back of the thermostat or in the full installation guide).
  • Assegureu-vos que totes les connexions estiguin segures i correctament aïllades.
  • The thermostat is designed to switch a maximum electrical load of 10 Amperes (resistive) or 3 Amperes (inductive). Do not exceed these ratings.

4.3. Torneu a muntar

  1. Once wiring is complete and verified, carefully replace the front cover onto the thermostat base.
  2. Restore power to the heating system at the consumer unit/fuse box.
Honeywell MT200 T4360A1009 Frost Protection Room Thermostat

Figure 1: Honeywell MT200 T4360A1009 Frost Protection Room Thermostat with rotary dial and protective cover.

5. Funcionament

The Honeywell MT200 T4360A1009 thermostat features a simple rotary dial for setting the desired temperature. The primary function is frost protection, ensuring your system does not freeze.

5.1. Configuració de la temperatura

  1. Locate the rotary dial on the front of the thermostat.
  2. Rotate the dial to align the desired temperature setting with the indicator mark. The temperature range for this thermostat is typically 0°C to 20°C.
  3. For frost protection, set the dial to a low temperature, typically around 5°C to 7°C, to prevent freezing without excessive heating.
  4. The thermostat will automatically switch the connected heating device (boiler or pump) on or off to maintain the set temperature.

The protective cover helps prevent accidental changes to the temperature setting once it has been established.

6. Manteniment

The Honeywell MT200 T4360A1009 thermostat is designed for reliable, long-term operation with minimal maintenance.

6.1. Neteja

  • To clean the exterior of the thermostat, wipe it with a soft, damp tela.
  • Do not use abrasive cleaners, solvents, or chemical sprays, as these can damage the plastic casing i components interns.
  • Ensure no liquid enters the thermostat housing.

6.2. Atenció general

  • No hi ha peces que l'usuari pugui reparar dins del termòstat. No intenteu obrir ni reparar la unitat vosaltres mateixos.
  • Ensure the thermostat is not obstructed by furniture or curtains, which could affect its ability to sense room temperature accurately.

7. Solució De Problemes

If you experience issues with your Honeywell MT200 T4360A1009 thermostat, please consult the following common problems and solutions before contacting support.

ProblemaCausa possibleSolució
Thermostat not switching heating on/offNo power to the unit; Incorrect wiring; Set temperature not reached.Check main power supply; Verify wiring connections (consult a qualified electrician); Adjust set temperature to be above/below current room temperature to test.
Inaccurate temperature sensingUbicació del termòstat afectada per corrents d'aire, llum solar directa o fonts de calor.Relocate the thermostat to a more suitable position away from external influences.
Protective cover difficult to remove/replaceImproper alignment or debris.Ensure proper alignment of the cover with the base; Clean any debris from the edges.

If the problem persists after attempting these solutions, please contact Honeywell customer support or a qualified heating engineer.

8. Especificacions

CaracterísticaDetall
MarcaHoneywell
Número de modelT4360A1009
Nom del producteMT200 Frost Protection Room Thermostat
Font d'alimentacióElèctric amb cable
Tipus de control de temperaturaManual (Rotary Dial)
Interval de temperatura de funcionament0 °C a 20 °C
Maximum Electrical Load (Resistive)10 A
Maximum Electrical Load (Inductive)3 A
Piles necessàriesNo
ColorBlanc

9. Garantia i Suport

Honeywell products are manufactured to high standards and are backed by a manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation included with your purchase or visit the official Honeywell weblloc.

For technical support, troubleshooting assistance beyond what is provided in this manual, or to inquire about replacement parts, please contact Honeywell customer service. Contact details can typically be found on the Honeywell weblloc web o a l'embalatge del producte.

When contacting support, please have your product model number (T4360A1009) and purchase date readily available.

Documents relacionats - MT200 T4360A1009

Preview Guia d'usuari del termòstat d'habitació programable Honeywell CM901
Guia d'usuari completa per al termòstat d'ambient programable Honeywell CM901. Aprèn sobre les característiques, la instal·lació, la programació, el funcionament, la resolució de problemes i consells d'estalvi d'energia per a un confort òptim a la llar.
Preview Honeywell CM927 Wireless Programmable Room Thermostat User Guide | Efficient Heating Control
Discover how to install, program, and operate the Honeywell CM927 wireless programmable room thermostat for optimal home comfort and energy savings. This user guide covers features, setup, and troubleshooting.
Preview Manual del producte del termòstat d'habitació sense fil Honeywell Home DTS92E
Manual complet del producte per al termòstat d'ambient sense fil Honeywell Home DTS92E. Aquesta guia cobreix la instal·lació, l'emparellament amb el sistema Link Plus, el funcionament bàsic, el mode ECO i les especificacions tècniques.
Preview Guia d'usuari del termòstat d'habitació programable Honeywell CM907
Guia d'usuari completa per al termòstat d'ambient programable de 7 dies Honeywell CM907, que detalla la configuració, la programació, el funcionament i la resolució de problemes per a un confort òptim a la llar i un estalvi d'energia.
Preview Guia de l'usuari del termòstat digital programable Honeywell FocusPRO sèrie 6000
Guia d'usuari del termòstat digital programable Honeywell FocusPRO sèrie 6000, que cobreix la instal·lació, la programació, funcions com la recuperació intel·ligent adaptativa, la protecció del compressor i la resolució de problemes.
Preview Guia de l'usuari del termòstat programable Honeywell T6 Pro
Obteniu instruccions detallades per al vostre termòstat programable Honeywell T6 Pro (model TH6220U2000). Aquesta guia de l'usuari cobreix la configuració, els horaris de programació, el funcionament del sistema i del ventilador, les funcions avançades com la recuperació adaptativa, la resolució de problemes i la informació de garantia per a un control eficient del clima a la llar.