1. Introducció

The Intermatic PX100 Safety Transformer is engineered to provide safe and reliable low-voltage power for pool and spa lighting, submersible fixtures, and outdoor garden lights. This manual provides essential information for the proper installation, operation, and maintenance of your PX100 transformer, ensuring compliance with safety standards and optimal performance.

2. Informació important de seguretat

ADVERTÈNCIA: Risc de descàrrega elèctrica o electrocució.

Installation must be performed by qualified personnel in accordance with all local, state, and national electrical codes, including NEC Code 680.23 for underwater luminaries. Always disconnect power at the circuit breaker before installation or servicing.

The transformer features a grounded shield between the primary and secondary windings to ensure safe operation. Built-in circuit protection will temporarily disconnect power in case of an overload. Allow approximately 15 minutes for the internal protector to reset after an overload or short circuit. Do not attempt to service any internal parts.

This equipment is not for use with self-contained portable spas or hot tubs. Do not install this equipment within 5 feet (1.5 meters) of the pool/spa wall.

3. Característiques del producte

  • Designed to supply 12-14 VAC to pool/spa lights, submersible fixtures, and outdoor garden lights.
  • Grounded shield between the primary and secondary windings for enhanced safety.
  • Built-in circuit protection with automatic reset to prevent damage from overload or short circuits.
  • Durable 3R Beige metal enclosure suitable for outdoor use.
  • Features 10 combination 1/2" - 3/4" knockouts for flexible wiring (2 right side, 2 left side, 2 back, 4 bottom).
  • Compact dimensions: 7.25" (H) x 5.25" (W) x 4.5" (D).
  • Reduces electronic noise and interference in low-voltage aplicacions d'il·luminació.
  • Constructed with super quiet stainless steel for minimal audible hum.
Intermatic PX100 100W Pool Light Transformer

Image: The Intermatic PX100 100W Pool Light Transformer, designed to supply power for pool/spa lights, submersible fixtures, and landscape lights.

Intermatic PX100 Low Voltage Converter Input and Output

Image: Diagram illustrating the low voltage conversion of the PX100 transformer, showing 120V AC input and 12V/13V/14V AC output.

Internal components of Intermatic PX100 transformer

Imatge: Una imatge interna view of the Intermatic PX100 transformer, highlighting premium construction, super quiet stainless steel, automatic breaker reset, and wiring flexibility.

4. Configuració i instal·lació

The Intermatic PX100 transformer is designed for straightforward installation. Always ensure power is disconnected before beginning any work.

  1. Mounting the Transformer:

    Fix the transformer securely to a wall or suitable surface using the included top and bottom mounting brackets. Ensure it is mounted at least 1 foot above ground and with the arrows on the label pointing up.

    Step 1: Fix the transformer on the wall

    Image: Step 1 of installation, showing how to fix the transformer to the wall using mounting screws.

  2. Connecting Input Power (120V AC):

    Connect the black (live) and white (neutral) wires from your 120V AC power source to the designated input terminals inside the transformer. Ensure connections are secure and insulated.

    Wiring diagram for Intermatic PX100 transformer

    Image: A simplified wiring diagram showing 120V AC input connected to the transformer, and the low voltage output connected to lights.

  3. Connecting Output Power (12V/13V/14V AC):

    Choose the appropriate output wire (12V, 13V, or 14V) based on your lighting requirements and connect it to your low voltage lighting system. The transformer provides flexibility for various wattage needs up to 100W max.

  4. Posada a terra:

    Ensure the transformer is properly grounded to prevent electrical hazards. Connect the ground wire to the designated ground terminal.

  5. Testing and Enclosure:

    After all connections are made and verified, test the system. Once confirmed operational, install the metal cover securely to protect the internal components from the elements.

Video: An official video from Intermatic demonstrating the features and installation aspects of their safety transformers, including the PX100 model. This video highlights the product's quiet operation, circuit protection, and ease of wiring.

5. Instruccions de funcionament

The Intermatic PX100 transformer operates automatically once properly installed and powered. It is designed for continuous operation to provide consistent low-voltage power to your connected lights.

  • Ensure the power supply to the transformer is always on for your lights to function.
  • The internal circuit protection will automatically reset after approximately 15 minutes if an overload or short circuit occurs. No manual reset is required.
  • The transformer is designed to operate quietly, minimizing noise interference with your outdoor environment.

6. Manteniment

The Intermatic PX100 transformer requires minimal maintenance due to its robust construction and sealed design. However, periodic checks are recommended to ensure longevity and safe operation:

  • Periodically inspect the transformer's enclosure for any signs of physical damage, corrosion, or loose connections.
  • Ensure the area around the transformer is clear of debris and allows for adequate ventilation.
  • Do not attempt to open the transformer or service any internal parts. Refer to qualified personnel for any repairs.

7. Solució De Problemes

If your Intermatic PX100 transformer or connected lights are not functioning as expected, consider the following:

ProblemaCausa possibleSolució
Lights are off or flickering.Overload or short circuit detected by internal protector.Disconnect power, check for shorts or excessive load. Allow 15 minutes for the internal protector to reset. Reconnect power.
Sense alimentació al transformador.Circuit breaker tripped or loose input wiring.Check the circuit breaker and ensure it is in the "ON" position. Verify input wiring connections are secure (consult qualified electrician).
Les llums són tènues.Vol incorrectetage tap selected or excessive wire length/gauge.Assegureu-vos que el volum correctetage tap (12V, 13V, or 14V) is used for your lights. Consult a professional to check wire gauge and length for voltage gota.

If issues persist after troubleshooting, contact a qualified electrician or Intermatic customer support.

8. Especificacions

CaracterísticaDetall
Número de modelPX100
Entrada Voltage120 VAC
Vol. De sortidatage12 VAC, 13 VAC, or 14 VAC
Wat màxtage100 watts
Freqüència60 Hz
Valoració actual1 Amp
Tipus de tancament3R Rainproof Metal Enclosure
Dimensions (A x A x P)7.25" x 5.25" x 4.5" (19.4 cm x 13.3 cm x 11.4 cm)
Pes de l'article5 lliures (2.27 kg)
ComplimentNEC Code 680.23, UL Listed

9. Garantia i Suport

The Intermatic PX100 Safety Transformer comes with a 1-year warranty from the date of purchase, covering defects in materials and workmanship. For warranty claims or technical support, please contact Intermatic customer service.

For additional information or to download the official user manual, please refer to the following resource:

Documents relacionats - PX100

Preview Manual d'instal·lació i funcionament dels transformadors d'il·luminació per a piscines i spas Intermatic
Aquest manual proporciona instruccions d'instal·lació, funcionament i seguretat per als compressors de baix volum Intermatic de la sèrie PX.tagTransformadors de llum per a jardins i piscines/spa, inclosos els models PX100, PX100S, PX300 i PX300S. Cobreix el cablejat, les precaucions de seguretat, les especificacions i la informació de garantia.
Preview Sèrie Intermatic PX de baix volumtagTransformadors electrònics: Manual d'instal·lació, funcionament i servei
Manual d'instal·lació, funcionament i servei per a Intermatic PX100, PX100S, PX300 i PX300S de baix volumtagtransformadors electrònics. Cobreix la seguretat, les especificacions, les pautes d'instal·lació, les taules de cablejat i la garantia per a la il·luminació de jardins, piscines i spas.
Preview Intermatic ML44T 44 Watts de baix volumtagGuia d'instal·lació del paquet d'alimentació d'il·luminació de paisatge
Guia d'instal·lació i usuari de l'Intermatic ML44T de 44 watts de baix volumtagPaquet d'alimentació per a il·luminació de paisatges. Cobreix els avisos de seguretat, la configuració, el funcionament del temporitzador i la resolució de problemes.
Preview Intermatic PF1103T PF1103MT Freeze Protection Control Installation Operation Service Manual
This manual provides detailed installation, operation, and troubleshooting instructions for the Intermatic PF1103T and PF1103MT freeze protection controls, designed for pool and spa equipment. Includes wiring diagrams and warranty information.
Preview Guia d'instal·lació i ús del paquet d'alimentació d'il·luminació de paisatge Intermatic ML44T de 44 watts
Aquesta guia proporciona instruccions per instal·lar i utilitzar el paquet d'alimentació per a il·luminació exterior Intermatic ML44T de 44 watts. Inclou avisos de seguretat, especificacions tècniques, procediments d'instal·lació pas a pas, configuració del temporitzador, consells per a la resolució de problemes i informació sobre la garantia.
Preview Manual d'instal·lació de la caixa de connexions elèctriques Intermatic PJB2175 i PJB4175
Installation, operation, and service manual for the Intermatic PJB2175 and PJB4175 electrical junction boxes designed for pool and spa luminaires. Includes safety instructions, general information, installation steps, troubleshooting, and warranty details.