Intermàtic E1010

Intermatic E1010 24-Hour Heavy Duty Mechanical Timer User Manual

Model: E1010 | Marca: Intermatic

1. Introducció

The Intermatic E1010 is a heavy-duty in-wall mechanical timer designed for controlling electrical loads such as lights, fans, and pumps. This 24-hour timer provides energy savings, enhanced security, and convenience by automating the operation of connected devices. It features a robust design suitable for continuous use and is programmable in 30-minute intervals, allowing for precise scheduling of one ON/OFF cycle per 24-hour period.

2. Informació de seguretat

ADVERTIMENT: Per reduir el risc d'incendi, descàrrega elèctrica o lesions personals, seguiu sempre aquestes precaucions de seguretat:

  • Always disconnect power at the circuit breaker or fuse box before installing or servicing the timer.
  • La instal·lació l'ha de dur a terme un electricista qualificat d'acord amb totes les normes elèctriques locals i nacionals.
  • Do not exceed the maximum electrical ratings of the timer (15 Amps, 125 VAC, 1500 Watts).
  • This device is intended for indoor use only. Do not expose to water or extreme humidity.
  • Assegureu-vos que totes les connexions dels cables estiguin segures i correctament aïllades.
  • Keep children away from electrical devices and wiring.

Avís de la Proposició 65: Aquest producte pot contenir substàncies químiques que l'estat de Califòrnia sap que causen càncer i defectes congènits o altres danys reproductius.

3. Contingut del paquet

Verifiqueu que tots els components siguin presents abans de començar la instal·lació:

  • Intermatic E1010 Mechanical Timer Unit
  • One (1) permanently attached ON/OFF tripper
  • Cargols d'instal·lació
  • Manual d'usuari (aquest document)

4. Configuració i instal·lació

The Intermatic E1010 timer is designed for in-wall mounting in a standard junction box. Follow these steps for proper installation:

  1. Desconnecteu l'alimentació: Locate the circuit breaker or fuse that controls the power to the junction box where the timer will be installed. Turn off the power completely. Verify power is off using a voltage provador.
  2. Preparació del cablejat: Carefully remove the existing switch or outlet from the junction box. Identify the line (hot), load, and ground wires.
  3. Connexions de cable: Connect the timer's wires to the household wiring according to the wiring diagram provided with the product (refer to product-specific wiring diagrams for detailed instructions). Typically, this involves connecting:
    • Line (incoming power) to the timer's line terminal.
    • Load (to the device being controlled) to the timer's load terminal.
    • Ground wire to the timer's ground screw.
    Assegureu-vos que totes les connexions estiguin estretes i segures.
  4. Temporitzador de muntatge: Gently push the wired timer into the junction box. Secure the timer to the junction box using the provided mounting screws.
  5. Instal·leu la placa frontal: Attach the decorative faceplate (not included, typically part of the wall plate) over the timer.
  6. Restaura l'alimentació: Torneu a connectar l'alimentació a l'interruptor o a la caixa de fusibles.
Intermatic E1010 24-Hour 15-Amps Heavy Duty Mechanical Timer, front view showing the time dial and trippers.

This image displays the front of the Intermatic E1010 mechanical timer, featuring a circular dial with hour markings (AM/PM, Noon/Night) and two adjustable trippers (one orange, one black) for setting ON/OFF times. The 'Intermatic' logo is visible at the bottom.

5. Instruccions de funcionament

The E1010 timer allows for one ON/OFF cycle within a 24-hour period using its permanently attached trippers. The dial is marked with AM/PM and Noon/Night indicators.

  1. Estableix l'hora actual: Rotate the central dial clockwise until the current time aligns with the stationary orange pointer located at the top of the dial. Ensure you differentiate between AM and PM hours (e.g., 3 PM is different from 3 AM).
  2. Estableix l'hora d'encesa: The orange tripper indicates the ON time. Slide this tripper around the dial to the desired time you want the connected device to turn ON. The timer is programmable in 30-minute intervals.
  3. Hora d'apagada: The black tripper indicates the OFF time. Slide this tripper around the dial to the desired time you want the connected device to turn OFF.
  4. Anulació manual: The timer can be manually turned ON or OFF by pushing the small lever located above the dial. Pushing it one way will turn the device ON, and pushing it the other way will turn it OFF, overriding the set program until the next scheduled event.

The timer will automatically cycle through the set ON and OFF times daily. The internal mechanism will continue to rotate the dial, advancing the time.

6. Manteniment

The Intermatic E1010 mechanical timer is designed for long-term, reliable operation with minimal maintenance. Follow these guidelines to ensure optimal performance:

  • Neteja: Periodically wipe the exterior of the timer with a soft, dry cloth. Do not use liquid cleaners, sprays, or abrasive materials, as these can damage the unit or cause electrical hazards.
  • Inspecció: From time to time, visually inspect the timer for any signs of damage, loose connections, or unusual wear. If any issues are observed, disconnect power and consult a qualified electrician.
  • Condicions ambientals: Ensure the timer is installed in a dry, indoor location within its specified operating temperature range. Avoid exposing the unit to excessive dust, moisture, or extreme temperatures.

7. Solució De Problemes

If you experience issues with your Intermatic E1010 timer, refer to the following common problems and solutions:

ProblemaCausa possibleSolució
Timer does not turn ON/OFF at set times.
  • Configuració de l'hora incorrecta.
  • Trippers are not correctly positioned.
  • Problema d'alimentació.
  • Fallada del mecanisme intern.
  • Ensure the current time is accurately set on the dial.
  • Verify the orange (ON) and black (OFF) trippers are securely placed at the desired times.
  • Check the circuit breaker for the connected circuit.
  • If the issue persists, the unit may require replacement.
Timer dial is not moving or losing time.
  • No hi ha alimentació al temporitzador.
  • Internal motor failure.
  • Check power supply at the circuit breaker.
  • The internal motor is not user-serviceable. The unit will need to be replaced.
Manual override not working.
  • Lever mechanism is stuck or damaged.
  • Gently attempt to move the lever. Do not force it. If it remains stuck or broken, the unit may need replacement.

For issues not listed above, or if troubleshooting steps do not resolve the problem, contact Intermatic customer support or a qualified electrician.

8. Especificacions

Número de modelE1010
MarcaIntermatic
Tipus24-Hour Mechanical In-Wall Timer
Voltage Classificació125 VCA, 60 Hz
Ampedat15 Amps
Wattage1500 watts
Max. Number of Operations12 per day (one ON/OFF cycle)
Min. ON Time1/2 Hour (30 minutes)
Programmable IntervalsIncrements d'30 minut
Dimensions (A x A x P)4-1/4" H x 3-1/4" W x 1-3/8" D (Product Description) / 5.75" H x 3.6" W x 3.35" D (Specifications)
Note: Dimensions may vary slightly based on measurement method.
MaterialPlàstic
Tipus de muntatgeWall Mount (Standard Junction Box)
CertificacionsCSA (Canada and US)
Pes de l'article0.7 Pounds / 11.2 ounces
UPC078275440005

9. Garantia i Suport

Garantia: The Intermatic E1010 timer comes with a 1-year limited warranty. This warranty covers replacement of the unit but does not include labor costs for installation or removal.

Atenció al client: For technical assistance, warranty claims, or further information, please contact Intermatic customer support. Refer to the official Intermatic weblloc web o l'embalatge del producte per obtenir les dades de contacte més actualitzades.

Si us plau, conserveu el comprovant de compra per motius de garantia.

Documents relacionats - E1010

Preview Com instal·lar i fer funcionar el temporitzador de paret de 24 hores Intermatic E-1020
Guia completa per a la instal·lació i el funcionament del temporitzador mecànic de paret Intermatic E-1020 de 24 hores amb programa múltiple. Inclou instruccions de cablejat, passos de programació i informació sobre la garantia.
Preview Manual d'usuari i garantia del temporitzador Intermatic TN311
Guia d'usuari i informació sobre la garantia limitada d'un any per al temporitzador de presa de corrent amb connexió a terra Intermatic TN311. Apreneu a configurar el programa, l'hora del dia i la anul·lació automàtica.
Preview Interruptor horari de marcatge de 24 hores Intermatic T105: guia d'instal·lació, cablejat i funcionament
Guia completa per a l'interruptor temporitzador mecànic de 24 hores Intermatic T105. Cobreix les especificacions del model, els avisos de seguretat, les instruccions de cablejat per a diverses configuracions (SPNO, SPNC, SPDT), els procediments de programació i el funcionament manual. Inclou una taula detallada de les classificacions elèctriques i les recomanacions de calibre de cable.
Preview Temporitzador automàtic de paret Intermatic E-1020 de 24 hores: Guia d'instal·lació i funcionament
Guia completa per a la instal·lació i el funcionament del temporitzador de programa múltiple automàtic de 24 hores Intermatic E-1020 per a la paret. Inclou instruccions pas a pas, diagrames de cablejat i detalls de la garantia.
Preview Temporitzador digital de 7 dies per a exteriors Intermatic HB880R: instruccions d'ús i guia de configuració
Manual d'usuari complet per al temporitzador digital de 7 dies per a exteriors Intermatic HB880R. Apreneu a instal·lar, programar, configurar horaris i solucionar problemes d'aquest interruptor horari versàtil.
Preview Guia d'instal·lació i funcionament del temporitzador de paret de 24 hores Intermatic E-1010
Instruccions detallades per instal·lar i fer funcionar el temporitzador automàtic de paret Intermatic E-1010 de 24 hores. Cobreix el cablejat, el funcionament manual, la configuració automàtica i la informació de garantia per a ús residencial.