Littelfuse SC-30

Manual d'instruccions del fusible Littelfuse Bussmann SC-30

1. Introducció

This manual provides essential information for the safe and effective use of the Littelfuse Bussmann SC-30 Fuse. It covers product overview, safety guidelines, installation, and specifications. Please read this manual thoroughly before handling or installing the fuse.

2. Informació de seguretat

WARNING: Electrical shock hazard. Always disconnect power before installing or replacing fuses. Installation should only be performed by qualified personnel.

  • Ensure the power supply is completely disconnected and locked out before any work involving fuses.
  • Never touch electrical components with wet hands or while standing on wet surfaces.
  • Utilitzeu sempre fusibles amb el volum correctetage i amperage ratings for the circuit they are protecting. Using an incorrect fuse can lead to equipment damage, fire, or personal injury.
  • No salteu ni tamper with fuses.
  • Utilitzeu equips de protecció individual (EPI) adequats, com ara guants aïllants i ulleres de seguretat, quan treballeu amb sistemes elèctrics.

3. Producte acabatview

The Littelfuse Bussmann SC-30 is a Class G, time-delay cartridge fuse designed for general purpose basic protection against overcurrents. It is rated for 30 Amperes and suitable for both AC (480V) and DC (300V) applications. The time-delay characteristic allows for temporary overcurrents, such as motor starting surges, without blowing, while still providing protection against sustained overloads and short circuits.

Bussmann SC-30 Class G Time-Delay Fuse with green label

Figura 3.1: Frontal view of the Bussmann SC-30 fuse, showing the green label with "BUSS Class G Fuse Type Ampere SC-30 Time-Delay" markings.

Bussmann SC-30 General Purpose Time-Delay Class G Fuse with white label

Figura 3.2: lateral view of the Bussmann SC-30 fuse, displaying detailed specifications including "General Purpose Basic Protection Time-Delay Class G Fuse SC-30 480Vac AC IR 100kA 300Vdc DC IR 10kA".

4. Instal·lació

Follow these steps for proper installation of the SC-30 fuse:

  1. Verificar la compatibilitat: Ensure the SC-30 fuse matches the required ampera i voltage ratings for your specific electrical circuit and equipment. Refer to your equipment's documentation.
  2. Desconnecteu l'alimentació: Absolutely ensure all power to the circuit where the fuse will be installed is turned off and locked out. Use a voltagun provador per confirmar que el circuit està desenergitzat.
  3. Remove Old Fuse (if applicable): Carefully remove the existing fuse from its holder. Note its orientation if it's a specific type.
  4. Inseriu un fusible nou: Insert the Bussmann SC-30 fuse into the fuse holder. Ensure it is seated firmly and correctly. Do not force the fuse.
  5. Restaura l'alimentació: Once the fuse is securely in place and all safety checks are complete, restore power to the circuit.
  6. Funcionalitat de prova: Verify that the protected equipment operates as expected.

Note: Fuses are designed for one-time use. A blown fuse must be replaced with a new one of the identical type and rating.

5. Principi de funcionament

The Bussmann SC-30 fuse functions as a sacrificial device designed to protect electrical circuits from overcurrent conditions. When the current flowing through the circuit exceeds the fuse's 30 Ampere rating for a sustained period (due to an overload) or instantaneously (due to a short circuit), the metallic element inside the fuse melts, creating an open circuit. This action interrupts the flow of electricity, preventing damage to wiring, equipment, and reducing the risk of fire.

As a time-delay fuse, the SC-30 is engineered to withstand temporary current surges that are common during the startup of motors or other inductive loads. This prevents nuisance blowing while still providing reliable protection against harmful overcurrents.

6. Manteniment

Fuses are generally maintenance-free components. However, periodic visual inspection of the fuse and its holder is recommended, especially in environments prone to vibration, dust, or extreme temperatures. Look for any signs of physical damage, discoloration, or loose connections. If any issues are observed, disconnect power and address them immediately.

7. Solució De Problemes

If a circuit protected by an SC-30 fuse stops functioning, the fuse may have blown. Follow these troubleshooting steps:

  • Identificació del fusible fundit: Disconnect all power to the circuit. Visually inspect the fuse for a broken filament or discoloration, which indicates it has blown. Some fuse holders may have an indicator.
  • Determinar la causa: A blown fuse indicates an overcurrent condition. Investigate the circuit for potential causes such as:
    • Overloaded circuit (too many devices drawing power).
    • Curtcircuit en el cablejat o en l'equipament.
    • Faulty equipment connected to the circuit.
  • Substituïu el fusible: Once the cause of the overcurrent is identified and rectified, replace the blown fuse with a new Littelfuse Bussmann SC-30 fuse. Never replace it with a fuse of a different rating.
  • Repeated Blowing: If the fuse blows repeatedly after replacement, it indicates a persistent problem in the circuit or equipment. Consult a qualified electrician to diagnose and repair the issue.

8. Especificacions

EspecificacióValor
MarcaLittelfuse (Bussmann)
Número de modelSC-30
AmpErage Rating30 Amps
Vol. ACtage Classificació480 Vac
DC Voltage Classificació300 V CC
Interrupting Rating (AC)100 kA
Interrupting Rating (DC)10 kA
Tipus de fusibleClass G, Time-Delay
Materialcoure
Tipus de muntatgeSurface Mount (Cartridge)
Pes de l'article0.317 unces
Dimensions del paquet2.56 x 1.1 x 0.43 polzades

9. Garantia i Suport

For warranty information and technical support regarding your Littelfuse Bussmann SC-30 fuse, please refer to the official Littelfuse weblloc web o contacteu directament amb el servei d'atenció al client. Conserveu el rebut de compra per a qualsevol reclamació de garantia.

Littelfuse Official Weblloc: www.littelfuse.com

Documents relacionats - SC-30

Preview Fusibles Littelfuse JLLN de classe T | Acció ràpida i alta capacitat d'interrupció
Exploreu els fusibles de classe T de la sèrie JLLN de Littelfuse, que ofereixen un disseny compacte, protecció contra sobrecàrregues i curtcircuits d'acció ràpida i altes classificacions d'interrupció de fins a 200,000 AIR. Ideals per a variadors, inversors i fonts d'alimentació. View especificacions, informació de comanda i dimensions.
Preview Fusibles d'alta velocitat Littelfuse POWR-SPEED sèrie L70QS: dades tècniques
Exploreu els fusibles d'alta velocitat de la sèrie Littelfuse POWR-SPEED® L70QS. Aquesta fitxa tècnica proporciona especificacions detallades, dimensions, corbes de temps-corrent i informació d'aplicació per a aquests fusibles de 700 V CA/CC, dissenyats per protegir dispositius semiconductors de potència en aplicacions industrials.
Preview Instruccions d'instal·lació del fusible Littelfuse Sealed M10 ZCASE
Instruccions d'instal·lació per al fusible Littelfuse Sealed M10 ZCASE, incloent-hi especificacions, informació de comanda i guia de muntatge pas a pas.
Preview Guia de modificació de la relació de voltes del TC: Nota tècnica de Littelfuse
Apreneu a modificar la relació de voltes dels transformadors de corrent (CT) Littelfuse amb aquesta nota tècnica, que inclou mètodes per sumar i restar voltes i exemples pràctics.ampComprendre els principis de funcionament del TC i els ajustos de relació.
Preview Portafusibles de cargol Littelfuse MEGA® Flex Series
Descobreix el portafusibles de cargol de 32 V de la sèrie MEGA® Flex de Littelfuse, dissenyat per a aplicacions d'alt corrent de fins a 500 amps. Coneix les seves característiques, avantatges i informació de comanda per a aquest portafusibles versàtil.
Preview Relés de protecció Littelfuse: catàleg complet per a la seguretat i l'eficiència industrial
Exploreu la gamma de relés de protecció Littelfuse, que inclou solucions avançades per a la protecció contra fallades a terra, la mitigació d'arcs elèctrics, la monitorització de motors i bombes, la protecció d'alimentadors i els sistemes de connexió a terra neutra. Milloreu la seguretat industrial i l'eficiència operativa.