Corning PC-420D

Manual d'usuari

Corning PC-420D Stirring Hot Plate with Digital Display

Model: 6795-420D

For laboratory and scientific applications

Producte acabatview

The Corning PC-420D Stirring Hot Plate is a precision instrument designed for heating and stirring various liquids and solutions in laboratory environments. It features a durable Pyroceram top plate, digital displays for both stirring speed (RPM) and temperature (degrees Celsius), and intuitive control knobs for precise adjustments. This unit is suitable for a wide range of applications in chemistry, biology, and other scientific fields.

Corning PC-420D Stirring Hot Plate with digital display

Una sobrecàrrega view of the Corning PC-420D Stirring Hot Plate. The unit features a white Pyroceram top plate, a grey base with two black control knobs (Stir and Heat), and two red LED digital displays for RPM and temperature. A power cord with a three-prong plug is visible on the right side.

Informació de seguretat

Please read and understand all safety precautions before operating the Corning PC-420D Stirring Hot Plate. Failure to follow these instructions may result in injury or damage to the equipment.

Configuració

  1. Desembalatge: Carefully remove the hot plate from its packaging. Inspect the unit for any signs of damage during transit. Retain packaging for future storage or transport.
  2. Col·locació: Position the hot plate on a clean, stable, and level laboratory bench or work surface. Ensure there is sufficient clearance around the unit for ventilation and safe operation.
  3. Connexió d'alimentació: Connect the three-prong power cord to a grounded 120V/60Hz electrical outlet. The unit is designed for U.S. power standards.
  4. Rod Mount Support: If using a support rod (sold separately), attach it to the built-in rod mount support on the rear of the unit.

Instruccions de funcionament

The Corning PC-420D features intuitive controls for both heating and stirring functions.

Controls acabatsview:

Procediment:

  1. Encès: Ensure the unit is plugged in. The power indicator light will illuminate.
  2. Setting Stirring Speed: Place a stir bar into your vessel and position the vessel on the center of the Pyroceram top plate. Turn the "Stir" knob clockwise to the desired RPM. The digital display will show the set speed. Adjust as needed for proper mixing.
  3. Configuració de la temperatura: Turn the "Heat" knob clockwise to the desired temperature in degrees Celsius. The digital display will show the set temperature and will blink until the set temperature is achieved. The temperature can be set in 5-degree C increments, ranging from 5°C to 550°C.
  4. Seguiment: Continuously monitor the process. The microprocessor-based control maintains consistent and repeatable temperature settings within ±2°C.
  5. Apagar: When finished, turn both the "Stir" and "Heat" knobs counter-clockwise to the "Off" position. Unplug the unit from the power source when not in use. Allow the hot plate to cool down completely before cleaning or moving. The "HOT TOP" indicator will remain lit until the surface temperature is below 60°C.
  6. Control de temperatura externa: The unit can be used with an external temperature controller and support rod (sold separately) for enhanced temperature precision. Refer to the external controller's manual for specific instructions.

Manteniment

Proper maintenance ensures the longevity and optimal performance of your Corning PC-420D Stirring Hot Plate.

Resolució de problemes

This section addresses common issues you might encounter with your hot plate.

Problema Causa possible Solució
La unitat no s'encén. No power to outlet; power cord not fully plugged in; unit malfunction. Check power outlet with another device. Ensure power cord is securely connected. If problem persists, contact customer support.
Temperature not reaching set point or fluctuating. Vessel too large for hot plate; insufficient power; external factors (drafts); unit malfunction. Ensure vessel size is appropriate. Minimize drafts. Verify power supply. If issue continues, contact customer support.
Stirrer not working or inconsistent. Stir bar not present or incorrect size; vessel not centered; liquid too viscous; unit malfunction. Ensure a suitable stir bar is in the vessel. Center the vessel on the plate. Reduce liquid viscosity if possible. Contact customer support if problem persists.
Digital display is blinking. Temperature has not yet reached the set point. This is normal operation. The blinking will stop once the set temperature is achieved.

For issues not listed here or if troubleshooting steps do not resolve the problem, please contact Corning customer support.

Especificacions

Característica Detall
Número de model PC-420D (6795-420D)
Material de la placa Pyroceram Glass-Ceramic
Dimensions de la placa 5" x 7" (aprox. 12.7 cm x 17.8 cm)
Interval de temperatura 5 °C a 550 °C
Precisió de la temperatura ±2 °C
Increments de temperatura 5 °C
Rang de velocitat d'agitació Variable (±5% of set speed)
Font d'alimentació 120V/60Hz
Ampedat 5.9 A
Watts 698 W
Dimensions del producte (L x A x A) 7"D x 5"W x 5"H (approx. 17.8 cm x 12.7 cm x 12.7 cm)
Pes de l'article 7.05 lliures (aprox. 3.2 kg)
Components inclosos Stirrer apparatus (stir bar)

Garantia i Suport

The Corning PC-420D Stirring Hot Plate comes with a garantia de dos anys from the date of purchase, covering defects in materials and workmanship under normal use. This warranty meets European Standards (EN).

For technical assistance, warranty claims, or service inquiries, please contact Corning customer support. Please have your model number (PC-420D or 6795-420D) and purchase date available when contacting support.

For the most up-to-date contact information, please visit the official Corning weblloc web o consulteu la documentació inclosa amb el producte.

Documents relacionats - PC-420D

Preview Manual d'instruccions de plaques calefactores, agitadors i agitadors/plaques calefactores Corning
Manual d'instruccions per a plaques calefactores, agitadors i agitadors/plaques calefactores amb pantalles digitals Corning i el controlador de temperatura 6795PR. Inclou instruccions d'ús, informació de seguretat, especificacions tècniques i detalls de la garantia.
Preview Manual d'instruccions de plaques calefactores, agitadors i agitadors/plaques calefactores Corning (120 V)
Manual d'instruccions complet per a les plaques calefactores, agitadors i agitadors/plaques calefactores de 120 V de Corning (sèries PC-200, PC-400, PC-600). Cobreix informació general, funcionament, manteniment, especificacions i seguretat.
Preview Manual d'usuari del sistema Corning Everon 6000 MIMO: configuracions, LED i especificacions de RF
Manual d'usuari detallat per als sistemes MIMO de la sèrie Everon 6000 de Corning Optical Communications. Cobreix configuracions 2x2, 2TO1 i 4TO1 amb components dLRU, DEU, DCU, RIU, BTS, dMRU i dHRU. Inclou definicions d'estat dels LED, versions de llançament i avisos d'exposició crítica a RF per a una instal·lació professional.
Preview Manual d'usuari de Corning MRU i HRU: Guia d'instal·lació i funcionament
Aquest manual d'usuari proporciona instruccions completes per a la instal·lació, configuració i funcionament dels sistemes MRU (Digital Medium-power Remote Unit) i HRU (High Power Remote Unit) de Corning, components essencials per a la infraestructura de xarxa sense fil.
Preview Corning Permeable Supports Selection Guide: Transwell and Falcon Cell Culture Inserts
A comprehensive guide from Corning and Fisher Scientific to select the optimal permeable supports, including Transwell and Falcon cell culture inserts, based on membrane type, pore size, format, and surface treatment for various research applications.
Preview Corning Matribot Bioprinter Instruction Manual
Comprehensive instruction manual for the Corning Matribot Bioprinter, detailing setup, operation, maintenance, and troubleshooting for advanced bioprinting applications in tissue engineering and 3D cell culture.