Intermatic 2T2502GA

Manual d'instruccions del temporitzador de carcassa de plàstic per a piscina/spa Intermatic 2T2502GA

Model: 2T2502GA

Introducció

This manual provides essential information for the proper installation, operation, and maintenance of the Intermatic 2T2502GA Pool/Spa Plastic Enclosure. This enclosure is designed to house compatible Intermatic T100 series time switches, offering protection in various environmental conditions.

Producte acabatview

The Intermatic 2T2502GA is a durable, rainproof plastic enclosure specifically engineered for pool and spa timer applications. Its robust construction ensures longevity and protection for internal electrical components.

  • Material: Heavy-duty industrial grade plastic, beige finish.
  • Classificació ambiental: NEMA 3R rated for both indoor and outdoor installations, providing protection against rain, sleet, and external ice formation.
  • Prevenció de l'òxid: Constructed from plastic to prevent rust, making it ideal for humid or wet environments.
  • Compatibilitat: Designed to house Intermatic T100 series time switches.
  • Nocauts: Features combination 0.5 and 0.75 inch nominal knockouts (one on the back, one on each side, and two on the bottom) for wiring convenience.
Intermatic 2T2502GA Plastic Enclosure, closed front view

Figura 1: Frontal view of the Intermatic 2T2502GA Plastic Enclosure in its closed position. This image displays the beige finish and the Intermatic logo.

Informació de seguretat

WARNING: Risk of electric shock. Installation and servicing must be performed by qualified personnel only.

  • Always disconnect power at the circuit breaker before installing or servicing the enclosure or any internal components.
  • Ensure all wiring complies with national and local electrical codes.
  • This plastic enclosure does not provide grounding for internal components. Proper grounding of the time switch and associated wiring must be established independently according to electrical codes.
  • Do not exceed the maximum electrical ratings of the time switch installed within the enclosure.

Instal·lació i Configuració

  1. Lloc de muntatge: Select a suitable indoor or outdoor location that is easily accessible for servicing and protected from physical damage. Ensure the surface is flat and capable of supporting the enclosure's weight.
  2. Muntatge de la carcassa:
    • Obriu la porta del tancament.
    • Use appropriate screws or fasteners (not included) to secure the enclosure to the mounting surface through the designated mounting holes.
  3. Preparing Knockouts:
    • Identify the required knockout locations (back, sides, bottom) for conduit entry.
    • Carefully remove the desired knockouts using a screwdriver and hammer. Exercise caution to avoid cracking the plastic.
    • Install appropriate conduit connectors and conduits.
  4. Installing the Time Switch:
    • The enclosure is designed for tool-free installation of compatible Intermatic T100 series time switches. The timer mechanism snaps into proprietary clips inside the box.
    • Refer to the specific instruction manual for your Intermatic T100 series time switch for detailed wiring instructions.
    • Assegureu-vos que totes les connexions elèctriques estiguin segures i correctament aïllades.
  5. Posada a terra: As this is a plastic enclosure, it does not provide an inherent ground path. Ensure that the time switch and all associated wiring are properly grounded according to local electrical codes. This may involve using a separate grounding conductor.
  6. Tancament del recinte: Once installation and wiring are complete, securely close the enclosure door. The door features a tongue-in-groove design for a rainproof seal.
Intermatic 2T2502GA Plastic Enclosure, open view mostrant l'interior

Figura 2: Interior view of the Intermatic 2T2502GA Plastic Enclosure with the door open. This image shows the internal mounting clips for the time switch and the knockout locations.

Manteniment

The Intermatic 2T2502GA enclosure requires minimal maintenance to ensure its protective function.

  • Neteja: Netegeu periòdicament l'exterior del recinte amb anuncisamp drap per eliminar la brutícia i les restes. Eviteu productes de neteja abrasius.
  • Inspecció: Regularly inspect the enclosure for any signs of physical damage, such as cracks, loose hinges, or a compromised latch. Ensure the door closes securely to maintain its rainproof rating.
  • Integritat del segell: Verify that the tongue-in-groove seal around the door remains intact and free of debris to prevent water ingress.

Resolució de problemes

This section addresses common issues related to the enclosure itself. For issues with the time switch, refer to its specific manual.

ProblemaCausa possibleSolució
Water inside enclosureDoor not fully closed; damaged seal; improperly installed conduit fittings.Ensure door is latched securely. Inspect door seal for damage and replace if necessary. Verify conduit fittings are tight and sealed.
La porta del recinte no tanca correctamentDamaged latch or hinges; obstruction.Inspect latch and hinges for damage. Clear any obstructions. If damaged, the enclosure may need replacement.
Plàstic esquerdatPhysical impact; improper knockout removal.A cracked enclosure compromises its NEMA 3R rating. Replace the enclosure immediately to maintain protection.

Especificacions

  • Model: 2T2502GA
  • Marca: Intermatic
  • Material: Heavy-duty Industrial Grade Plastic
  • Acabat: Beix
  • Classificació ambiental: NEMA 3R (Resistent a la pluja)
  • Dimensions (A x A x P): 9-3/8 inches (23.8 cm) x 5-1/2 inches (14.0 cm) x 3-5/8 inches (9.2 cm)
  • Nocauts: Combination 0.5 and 0.75 inch nominal (one back, two sides, two bottom)
  • Compatibilitat: Intermatic T100 series time switches

Garantia i Suport

Garantia: This product is covered by a 1-year warranty for replacement of the unit. Labor costs are not included.

For technical support or warranty claims, please contact Intermatic customer service. Refer to the official Intermatic weblloc web per obtenir informació de contacte actualitzada.

Note: Warranty terms are subject to change. Please refer to the official Intermatic warranty statement for the most up-to-date information.

Documents relacionats - 2T2502GA

Preview Instruccions d'instal·lació de la carcassa impermeable per a interruptors temporitzadors Intermatic totalment de plàstic
Guia d'instal·lació detallada per a la carcassa impermeable de plàstic per a interruptors temporitzadors Intermatic, que cobreix el muntatge de la caixa, les connexions de conductes i els requisits de connexió a terra d'acord amb el Codi Elèctric Nacional.
Preview Com utilitzar i configurar els temporitzadors Intermatic de la sèrie T100
Una guia completa per al funcionament i la configuració dels temporitzadors mecànics de la sèrie Intermatic T100, inclosos els models T101, T103, T104, T105 i T106. Apreneu sobre les especificacions del temporitzador, les precaucions de seguretat, la configuració dels disparadors ON/OFF, l'ús de l'accionament manual i la cerca de recursos per a la resolució de problemes i les peces de recanvi.
Preview Guia d'instal·lació i programació de l'interruptor temporitzador d'il·luminació Intermatic EJ341C/EJ343C
Instruccions detallades per instal·lar i programar els interruptors temporitzadors d'il·luminació Intermatic EJ341C (unipolar) i EJ343C (tripolar). Cobreix la configuració, els controls, els mètodes de programació, la resolució de problemes i les especificacions.
Preview Guia d'instal·lació i funcionament del temporitzador de compte enrere electrònic per a la paret Intermatic EI200
Guia detallada per a la instal·lació i el funcionament del temporitzador de compte enrere electrònic Intermatic EI200 per a la paret. Les característiques inclouen rangs de temps de 5 a 30 minuts, mode HOLD continu i classificacions per a motors d'ús general de 15 A, de tungstè de 1000 W i de 1/4 HP. Inclou informació sobre la garantia.
Preview Control temporitzador electrònic Intermatic ET8215C - Dades tècniques
Especificacions tècniques detallades per al control temporitzador electrònic Intermatic ET8215C, un control electrònic astronòmic de 7 dies i 2 circuits adequat per a aplicacions de 120-277 VAC en una carcassa metàl·lica interior.
Preview Intermatic T173 T170 Interruptor temporitzador mecànic - 24 hores, 125 V, 5 CV
Especificacions detallades per a l'interruptor temporitzador mecànic Intermatic T173 T170. Compta amb configuració de 24 hores, 125 V CA, potència del motor de 5 CV, contactes 2NO DPST i carcassa NEMA 1. Apte per a aplicacions comercials, industrials, residencials, exteriors i HVACR.