FRYMASTER GF14

Frymaster GF14 Commercial Gas Fryer User Manual

Model: GF14

Introducció

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Frymaster GF14 16" GF Series Commercial Gas Fryer. This floor model fryer features a 40 lb. oil capacity, an open-pot design, and millivolt controls. It is equipped with a master jet burner, a temperature probe, and a 1-1/4" IPS ball type drain valve for easy oil management. The unit includes a rack-type basket support, basket hanger, flue deflector, and twin baskets. Constructed with stainless steel frypot, door, and cabinet, it is designed for commercial use with 100,000 BTU/hr output.

Please read these instructions thoroughly before installation or operation to ensure proper use and to prevent potential hazards.

Precaucions de seguretat

Always follow local and national codes for gas appliance installation. Ensure adequate ventilation. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Keep the area around the fryer clear and free from combustible materials.

Configuració i instal·lació

Proper installation is crucial for the safe and efficient operation of your Frymaster GF14 fryer.

Desembalatge

Carefully remove the fryer from its packaging. Inspect for any shipping damage. Report any damage to the carrier immediately.

Ubicació

Place the fryer on a level, non-combustible surface. Ensure sufficient clearance from walls and other equipment for proper ventilation and maintenance access. The fryer requires adequate ventilation to dissipate heat and exhaust combustion byproducts. Consult local codes for specific ventilation requirements.

Frymaster GF14 Commercial Gas Fryer with optional casters

Figura 1: Frontal view of the Frymaster GF14 Commercial Gas Fryer. This image shows the stainless steel construction, the top section with two fry baskets, and the lower cabinet. The unit is depicted with optional casters for mobility.

Connexió de gas

Connect the fryer to the appropriate gas supply (natural gas or propane) as indicated on the appliance rating plate. All gas connections must be made by a qualified technician and comply with all local and national gas codes. Ensure all connections are leak-tested before operation.

Connexió elèctrica

The GF14 model uses millivolt controls and typically does not require an external electrical connection for basic operation, as the pilot light generates the necessary millivolts. However, if your model includes optional accessories (e.g., filtration systems), ensure they are connected to a grounded electrical supply according to local codes.

Instruccions de funcionament

Filling the Frypot

Before lighting the pilot, ensure the frypot is filled with cooking oil or solid shortening to the MIN OIL LEVEL mark. If using solid shortening, melt it slowly at a low temperature setting before increasing to desired frying temperature.

Il·luminació del pilot

  1. Gireu el botó del termòstat a la posició OFF posició.
  2. Push in and hold the thermostat knob, then turn it to the PILOT posició.
  3. While holding the knob in, light the pilot burner with a match or lighter. Hold the knob in for approximately 30-60 seconds after the pilot lights to allow the thermocouple to heat up.
  4. Release the knob. If the pilot goes out, repeat the process.

Funcionament del cremador principal

Once the pilot is lit, turn the thermostat knob to the desired frying temperature. The main burner (master jet burner) will ignite automatically and cycle on and off to maintain the set temperature, monitored by the temperature probe. The auto high temperature shut-off feature will activate if the oil temperature exceeds safe limits.

Fregir

Place food items into the twin baskets and carefully lower them into the hot oil. Do not overload the baskets, as this can lower oil temperature and result in soggy food. Use the basket hanger to drain excess oil after frying.

Manteniment i Neteja

Regular cleaning and maintenance extend the life of your fryer and ensure food quality.

Neteja diària

Manteniment setmanal/mensual

Resolució de problemes

This section provides solutions to common operational issues. For problems not listed here, contact a qualified service technician.

ProblemaCausa possibleSolució
Pilot will not light or stay lit.No gas supply; Thermocouple not heating sufficiently; Pilot orifice clogged.Check gas valve; Hold thermostat knob in longer; Clean pilot orifice.
El cremador principal no s'encén.Pilot not lit; Thermostat set too low; Gas valve closed; Main burner orifice clogged.Light pilot; Increase thermostat setting; Open gas valve; Clean burner orifice.
Oil not heating to desired temperature.Thermostat malfunction; Low gas pressure; Excessive food load.Contact service technician; Verify gas supply pressure; Reduce batch size.
High temperature shut-off activates frequently.Thermostat calibration issue; Overheating due to poor ventilation; Sensor malfunction.Ensure proper ventilation; Contact service technician for calibration or sensor check.

Especificacions

CaracterísticaDetall
ModelGF14
MarcaFRYMASTER
TipusCommercial Gas Fryer, Floor Model
Capacitat d'oli40 lliures
Entrada BTU100,000 BTU/hora
ControlsMillivolt Controls, Temperature Probe
Característiques de seguretatAuto High Temperature Shut Off
Vàlvula de drenatge1-1/4" IPS Ball Type
Material de construccióStainless Steel (Frypot, Door, Cabinet)
Dimensions (L x A x A)91.44 cm x 55.88 cm x 118.11 cm (36" ​​x 22" x 46.5")
Pes de l'article68.95 kg (152 lliures)
CertificacionsNSF, CSA

Garantia i Suport

Warranty information for the Frymaster GF14 Commercial Gas Fryer is typically provided by the manufacturer at the time of purchase. Please refer to the documentation included with your fryer or contact Frymaster directly for specific warranty terms and conditions.

For technical support, parts, or authorized service, please contact Frymaster customer service or an authorized service agent in your region. Ensure you have your model number (GF14) and serial number ready when contacting support.

Documents relacionats - GF14

Preview Guia d'operació i manteniment de la fregidora Frymaster sèrie GF
Una guia per a la posada en marxa inicial, el funcionament diari i el manteniment preventiu de les fregidores Frymaster de la sèrie GF, models GF14 i GF40.
Preview Instruccions d'instal·lació del kit d'orifici per a fregidora de gas Frymaster GF14 GF40 per a gran altitud
Instruccions detallades per instal·lar el kit d'orificis per a gran altitud a les fregidores de gas Frymaster GF14 i GF40. Inclou números de peça, mides d'orificis, precaucions de seguretat i guia d'instal·lació pas a pas.
Preview Frymaster GF14 i GF40 Series Freidoras a Gas: Manual d'Instal·lació, Operació i Manteniment
Manual detallado para la instalación, operación y mantenimiento de las freidoras a gas Frymaster GF14 y GF40. Incluye información de seguridad, procedimientos de arranque, limpieza, solución de problemas y requisitos de código.
Preview Manual d'instal·lació i funcionament de la fregidora de gas Frymaster Super Runner SR42, SR52, SR62
Manual complet d'instal·lació i funcionament de les fregidores de gas Frymaster Super Runner, models SR42, SR52 i SR62. Cobreix els procediments de seguretat, instal·lació, conversió de gas, funcionament i manteniment.
Preview Frymaster Chipotle Equipment Start-up Guide and Checklist
Official Frymaster equipment start-up form and checklist for Chipotle locations. Covers installation, safety, gas, electric, and filtration system checks for commercial fryers.
Preview Frymaster FilterQuick Controller Version 2 Operation Manual
This operation manual provides comprehensive instructions for the Frymaster FilterQuick Controller Version 2, covering setup, operation, menu navigation, troubleshooting, and Oil Quality Sensor (OQS) functions. It includes model number FRY_IOM_8197206 and details on maintaining optimal oil quality for food service operations.