Bristan CART 06734B

Bristan Brass Thermostatic Cartridge User Manual

Model: CART 06734B

1. Introducció

This user manual provides essential information for the installation, maintenance, and troubleshooting of your Bristan Brass Thermostatic Cartridge, model CART 06734B. This cartridge is a critical component designed to regulate water temperature in compatible Bristan shower systems, ensuring a consistent and safe showering experience. Please read these instructions carefully before proceeding with installation or maintenance.

2. Informació de seguretat

  • Always turn off the main water supply before attempting any installation or maintenance on your shower system.
  • Si no esteu segurs de cap pas, consulteu un lampista qualificat.
  • Durant la instal·lació, utilitzeu l'equip de protecció individual (EPI) adequat, com ara guants i ulleres de protecció.
  • Assegureu-vos que totes les connexions estiguin ben fixades per evitar fuites.
  • Do not use harsh chemicals or abrasive cleaners on the cartridge or surrounding components.

3. Producte acabatview

The Bristan Brass Thermostatic Cartridge (CART 06734B) is a precision-engineered component responsible for mixing hot and cold water to achieve a desired, stable temperature. It is specifically designed for Bristan 1901 series thermostatic showers and is characterized by its non-threaded design.

Bristan Brass Thermostatic Cartridge, upright view

Imatge 1: Frontal view of the Bristan Brass Thermostatic Cartridge, showing the top spline and the spring at the base. This view highlights the overall shape and key connection points.

Bristan Brass Thermostatic Cartridge, side view

Imatge 2: Lateral view of the Bristan Brass Thermostatic Cartridge, illustrating its cylindrical body and the internal components, including the spring mechanism. This angle provides a clearer perspective of its length and seals.

4. Instal·lació

This cartridge is a replacement part. Installation should only be performed after the existing cartridge has been safely removed.

4.1. Preparació

  1. Turn off the main water supply to your property or the specific shower unit.
  2. Drain any residual water from the shower system by opening the shower valve.
  3. Remove the shower controls (handles, faceplate) to access the cartridge housing.
  4. Carefully remove the old cartridge. Note its orientation for correct installation of the new one.

4.2. Cartridge Installation

  1. Ensure the cartridge housing is clean and free of debris.
  2. Apply a small amount of silicone grease (often supplied with the cartridge) to the O-rings of the new cartridge to facilitate smooth insertion and ensure a good seal.
  3. Carefully insert the new Bristan Brass Thermostatic Cartridge into the housing, ensuring it is correctly aligned. The non-threaded design means it will slide into place.
  4. Secure the cartridge in place using the retaining nut or clip, as per your shower model's design. Do not overtighten.
  5. Reattach the shower controls (handles, faceplate). Ensure handles are correctly aligned for temperature and flow control.

4.3. Comprovació posterior a la instal·lació

  1. Slowly turn the main water supply back on.
  2. Check for any leaks around the cartridge housing and connections.
  3. Test the shower's temperature and flow controls to ensure proper operation and temperature stability.

5. Principis de funcionament

Once installed, the Bristan Brass Thermostatic Cartridge automatically maintains the desired water temperature. It contains a wax element that expands and contracts in response to temperature changes, adjusting the mix of hot and cold water to compensate for fluctuations in either supply. This ensures a constant, comfortable, and safe water temperature, preventing scalding or sudden cold shocks.

6. Manteniment

  • Neteja: The cartridge itself does not require regular cleaning. However, if water quality is poor (e.g., hard water), mineral deposits can build up over time.
  • Calç: In hard water areas, limescale can affect cartridge performance. If you notice temperature fluctuations or reduced flow, the cartridge may need descaling. This typically involves removing the cartridge and soaking it in a suitable descaling solution designed for brass components, following the descaler's instructions.
  • Lubricació: Periodically, the O-rings can be re-lubricated with silicone grease to ensure smooth operation and prevent wear. This is usually done during descaling or if the shower controls become stiff.

7. Solució De Problemes

ProblemaCausa possibleSolució
Temperatura de l'aigua inconsistentLimescale buildup on cartridge, faulty cartridge, fluctuating water pressure.Descale cartridge, check water pressure, replace cartridge if necessary.
Sense aigua calenta o fredaBlocked cartridge, supply issue, cartridge installed incorrectly.Check water supply, remove and inspect cartridge for blockages or incorrect installation.
Water leaking from shower controlsDamaged O-rings, loose retaining nut, faulty cartridge.Inspect and replace O-rings, tighten retaining nut, replace cartridge.
Stiff or difficult to turn controlsLack of lubrication on O-rings, limescale.Lubricate O-rings with silicone grease, descale cartridge.

If problems persist after attempting these solutions, it is recommended to contact a qualified plumber or Bristan customer support.

8. Especificacions

  • Model: CART 06734B
  • Tipus: Thermostatic Cartridge (not threaded)
  • Material: Llautó
  • Fabricant: Bristan
  • Dimensions del paquet: 14.4 x 5.4 x 5.4 cm
  • Pes de l'article: 200 g
  • Compatibilitat: Designed for specific Bristan 1901 series thermostatic showers (e.g., Bristan 1901 3 Control Thermostatic Shower, Bristan 1901 Easytherm Thermostatic Shower Adjustable Riser, Bristan 1901 Thermostatic Shower - Chrome - N TSHCVO C, Bristan 1901 Thermostatic Shower - Gold).

9. Garantia i Suport

For specific warranty information regarding your Bristan Brass Thermostatic Cartridge (CART 06734B), please refer to the documentation provided with your original Bristan shower unit or visit the official Bristan weblloc. Els termes de la garantia solen cobrir els defectes de fabricació.

For technical support, spare parts, or further assistance, please contact Bristan customer service directly. Contact details can usually be found on the Bristan website or in your original product packaging.

Documents relacionats - CART 06734B

Preview Bristan Altum 2 Tap Hole Wall Mounted Basin Mixer Brushed Brass (AL 2TH WMBAS BB) - Technical Specification
Detailed technical specifications and features for the Bristan Altum 2 Tap Hole Wall Mounted Basin Mixer in Brushed Brass (Model AL 2TH WMBAS BB). Includes dimensions, flow rates, materials, and certifications.
Preview Guia d'instal·lació i manual d'usuari de la vàlvula de dutxa Bristan RS2 SHCDIV C
Instruccions d'instal·lació completes, guia d'usuari i consells per a la resolució de problemes de la vàlvula de dutxa Bristan RS2 SHCDIV C. Més informació sobre les especificacions, el manteniment i el funcionament.
Preview Vàlvula mescladora termostàtica Bristan TS4753ECP: instal·lació, guia d'usuari i manteniment
Instruccions completes d'instal·lació, guia d'usuari, posada en marxa i procediments de manteniment per a la vàlvula mescladora termostàtica Bristan TS4753ECP. Inclou especificacions i resolució de problemes.
Preview Bristan TMV2 Service Installation Instructions and User Guide
Comprehensive installation instructions and user guide for Bristan's TMV2 Service thermostatic mixing valves, covering general information, conditions of use, commissioning, and in-service testing.
Preview Bristan Qubo Basin Guia d'instal·lació i usuari de l'aixeta mescladora QB BAS C
Guia completa d'instal·lació, funcionament, manteniment i resolució de problemes del Bristan Qubo Basin Aixeta mescladora (model QB BAS C). Inclou instruccions pas a pas, llista de peces i consells generals de cura.
Preview Guia d'instal·lació i ús de la dutxa termostàtica Bristan Power 1000
Comprehensive installation and user guide for the Bristan Thermostatic Power Shower 1000 (Model HY POWSHX10 W), covering safety, water and electrical requirements, product features, operation, dimensions, specification, installation steps, commissioning, maintenance, troubleshooting, and spare parts.