Idec RJ1S-C-D12

IDEC RJ1S-C-D12 Slim Power Relay User Manual

Model: RJ1S-C-D12

1. Producte acabatview

The IDEC RJ1S-C-D12 is a compact and efficient RJ Series Slim Power Relay designed for various industrial control applications. This single-pole double-throw (SPDT) relay operates on a 12 VDC coil voltage and features blade terminals for plug-in mounting, typically used with SJ sockets. It is engineered for reliable switching of electrical circuits, handling currents up to 12 Amps at 250 VAC or 30 VDC.

IDEC RJ1S-C-D12 Slim Power Relay, perspective view

Figura 1: Perspectiva view of the IDEC RJ1S-C-D12 Slim Power Relay, showing its compact design and transparent casing.

IDEC RJ1S-C-D12 Slim Power Relay, bottom view amb pinout

Figura 2: A baix view of the IDEC RJ1S-C-D12 relay, illustrating the blade terminals and coil voltage marking (12VDC).

2. Informació de seguretat

Always observe the following safety precautions to prevent injury or damage to the product and associated equipment:

  • Ensure power is disconnected before installation, wiring, or maintenance.
  • Verify that the relay's voltagLes classificacions e i actuals coincideixen amb els requisits de l'aplicació.
  • Do not exceed the specified contact ratings (12 Amps, 250 VAC, 30 VDC).
  • Install the relay in an appropriate enclosure to protect it from environmental factors and accidental contact.
  • Només personal qualificat ha de realitzar la instal·lació i el cablejat.
  • Avoid touching terminals when power is applied.

3. Configuració i instal·lació

The RJ1S-C-D12 relay is designed for plug-in mounting, typically into compatible SJ sockets (sold separately). Follow these steps for proper installation:

  1. Desconnexió d'alimentació: Before beginning, ensure all power to the circuit is turned off and locked out to prevent accidental energization.
  2. Preparació de la presa: If not already installed, mount the appropriate SJ socket securely in your control panel or enclosure. Ensure wiring to the socket terminals is correct according to your circuit diagram.
  3. Inserció de relé: Align the blade terminals of the RJ1S-C-D12 relay with the corresponding slots in the SJ socket. Gently but firmly push the relay into the socket until it is fully seated. The relay should click into place if the socket has a locking mechanism.
  4. Verificació: Double-check that the relay is securely seated and that all terminals are properly engaged.
  5. Restauració d'energia: Once installation is complete and verified, power can be safely restored to the circuit.

Nota: The relay's coil is rated for 12 VDC. Ensure the control voltage applied to the coil terminals matches this specification to prevent damage or improper operation.

4. Principis de funcionament

The IDEC RJ1S-C-D12 is a Single-Pole Double-Throw (SPDT) relay. This means it has one common contact that can switch between two other contacts (normally open and normally closed).

  • Estat desenergitzat: Quan no voltage is applied to the 12 VDC coil, the common contact is connected to the Normally Closed (NC) contact.
  • Estat energitzat: When 12 VDC is applied to the coil, an electromagnetic field is generated, which pulls the common contact away from the NC contact and connects it to the Normally Open (NO) contact.
  • Classificacions del contacte: The relay contacts are rated for switching loads up to 12 Amps. The maximum voltage for AC loads is 250 VAC, and for DC loads, it is 30 VDC. Adhering to these ratings is crucial for the longevity and safe operation of the relay.

5. Manteniment

The RJ1S-C-D12 relay is designed for long-term reliability with minimal maintenance. However, periodic inspection can help ensure optimal performance:

  • Inspecció visual: Periodically inspect the relay and its socket for any signs of physical damage, discoloration, or loose connections. Ensure the transparent casing is intact.
  • Terminal Integrity: Check that the blade terminals are clean and free from corrosion. If necessary, gently clean them with a non-abrasive, electrical contact cleaner (with power off).
  • Condicions ambientals: Assegureu-vos que l'entorn de funcionament es mantingui dins dels rangs de temperatura i humitat especificats per evitar un desgast prematur.
  • Substitució: Relays have a finite mechanical and electrical life. If the relay exhibits inconsistent operation, excessive heat, or visible contact pitting, it should be replaced.

6. Solució De Problemes

If the RJ1S-C-D12 relay is not functioning as expected, consider the following common issues and solutions:

ProblemaCausa possibleSolució
Relay coil does not energize.No 12 VDC power to coil; incorrect voltage; faulty coil.Verify 12 VDC supply to coil terminals. Check wiring. Replace relay if coil is faulty.
Contacts do not switch or are intermittent.Overload condition; worn contacts; insufficient coil voltage; dirty terminals.Check load current against relay rating. Replace relay if contacts are worn. Verify stable 12 VDC coil voltage. Clean terminals.
Relay makes buzzing noise.AC voltage applied to DC coil; loose connection; mechanical issue.Ensure only 12 VDC is applied to the coil. Check for secure seating in socket. Replace relay if mechanical issue persists.
Relay overheats.Overcurrent on contacts; excessive coil voltage; poor ventilation.Reduce load current to within specifications. Verify coil voltage is 12 VDC. Ensure adequate airflow around the relay.

7. Especificacions

AtributValor
MarcaIdec
Número de modelRJ1S-C-D12
Bobina Voltage12 VDC
Tipus de contacteSPDT (Unipolar de Doble Direcció)
Valoració actual12 Amps
Max AC Voltage250 VAC
Max DC Voltage30 VDC
Tipus de muntatgeMuntatge endollat
Tipus de connectorPlug-In (Blade Terminals)
Pes de l'article3.2 unces
FabricantIDEC Corp.
Data de primera disponibilitat16 de març de 2014

8. Garantia i Suport

For information regarding warranty, technical support, or service for your IDEC RJ1S-C-D12 Slim Power Relay, please contact IDEC Corp. directly through their official website or customer service channels. Keep your purchase receipt and product model number (RJ1S-C-D12) available when seeking support.

Documents relacionats - RJ1S-C-D12

Preview IDEC RF1V Force Guided Relays & SF1V Relay Sockets | Safety Circuit Components
Explore IDEC's RF1V Force Guided Relays and SF1V Relay Sockets, designed for flexible and reliable safety circuit construction. Features include EN50205 compliance, fast response, and shock resistance.
Preview Guia de selecció de relés IDEC
A comprehensive guide to selecting IDEC relays, covering various series like RV8H, RJ, RH, RU, RR, RL, RY, RF, and RSC solid-state relays. It details specifications, features, and cross-references for industrial applications.
Preview Interruptors i llums pilot IDEC sèrie YW: catàleg complet de productes
Exploreu la sèrie IDEC YW d'interruptors i llums pilot de Ø22 i Ø30, incloent-hi interruptors d'aturada d'emergència, botons polsadors, interruptors selectors, interruptors selectors de clau i llums pilot. View especificacions, números de peça, dimensions i accessoris.
Preview Relés universals de la sèrie IDEC RU: característiques, especificacions i aplicacions
Una guia completa dels relés miniatura universals de la sèrie IDEC RU, que detalla les seves característiques, especificacions tècniques, corbes de vida elèctrica, dimensions, números de peça, endolls aplicables i precaucions de seguretat per a l'automatització industrial.
Preview IDEC SmartRelay FL1F: IIoT-Ready Compact Programmable Relay
Discover the IDEC SmartRelay FL1F, a versatile and compact IIoT-ready programmable relay designed for efficient automation, control, and remote monitoring. This document details its features, extensive I/O capabilities, communication protocols (Modbus TCP, MQTT), web server functionality, and comprehensive technical specifications.
Preview IDEC XW7E-BS312PK Collector User Manual and Specifications
Comprehensive user manual and technical specifications for the IDEC XW7E-BS312PK Collector, including safety precautions, electrical ratings, dimensions, mounting, wiring, maintenance, and troubleshooting.