Red Lion 97101001

Red Lion RL-SPRK100 Sprinkler Pump User Manual

Model: 97101001

1. Producte acabatview

The Red Lion RL-SPRK100 is a 1 HP sprinkler pump designed for residential and light commercial lawn and turf sprinkling systems. It features a rugged cast iron casing and a high-efficiency thermoplastic impeller and diffuser. This pump is engineered for reliable performance and ease of use.

Red Lion RL-SPRK100 Sprinkler Pump

Image 1.1: The Red Lion RL-SPRK100 Sprinkler Pump, showcasing its red cast iron housing.

Característiques principals:

  • Construcció duradora: Features a rugged cast iron pump housing and a glass-filled thermoplastic impeller, suitable for various water sources including well water and lake water.
  • Dual Voltage Motor: Operates on either 115 Volts or 230 Volts. The pump is factory-set to 230 Volts but can be easily reconfigured to 115 Volts. It is crucial to match the pump's voltage setting to the power source voltage per a un bon funcionament.
  • Capacitat d'autoaspirant: Requires only a one-time initial prime. No additional priming is necessary after the initial fill, simplifying setup.
  • Alt rendiment: Delivers up to 63 Gallons Per Minute (GPM) at 10 PSI and 38 GPM at 30 PSI. Capable of supporting up to 12 sprinkler heads with 1/2-inch fittings or 6 sprinkler heads with 3/4-inch fittings per zone.
  • Standard Connections: Equipped with a 2-inch Female NPT threaded intake and a 1.5-inch Female NPT threaded discharge.
Red Lion RL-SPRK100 Sprinkler Pump Features

Image 1.2: Diagram highlighting key features of the pump, including the 2-inch FNPT intake, 1-1/2-inch FNPT discharge, cast iron casing, capacitor start, and thermally protected motor.

2. Configuració i instal·lació

Proper installation is essential for the safe and efficient operation of your Red Lion RL-SPRK100 Sprinkler Pump. Refer to the complete installation manual included with your pump for detailed instructions and safety warnings.

2.1 voltage Configuració

The pump motor is factory-set to 230 Volts. If your power supply is 115 Volts, you must adjust the motor's voltage setting before operation. Failure to match the pump's voltage to the source voltage will prevent the pump from performing to specifications and may cause damage.

Red Lion RL-SPRK100 Dual Voltage Motor Setting

Image 2.1: Instructions for setting the dual voltage motor. The pump is factory preset to 230V. To switch to 115V, insert a flat screwdriver into the black voltage change indicator and twist counter-clockwise.

2.2 Cebament de la bomba

The RL-SPRK100 is a self-priming pump, meaning it only requires an initial prime. After the initial fill, no additional priming is typically required. Follow these general steps for initial priming:

  1. Assegureu-vos que totes les connexions de fontaneria siguin segures i no tinguin fuites.
  2. Traieu el tap d'encebament (normalment situat a la part superior de la bomba c)asing).
  3. Ompliu la bomba casing completely with water until it overflows.
  4. Substituïu i estrenyeu el tap d'encebament.
  5. Open any discharge valves to allow air to escape the system.
  6. Start the pump. It should begin pumping water within a few minutes. If not, turn off the pump, re-prime, and check for air leaks in the suction line.
Red Lion RL-SPRK100 Self-Priming Feature

Image 2.2: The Red Lion Sprinkler Pump positioned in a lawn setting, illustrating its self-priming capability up to 25 feet after the initial prime.

3. Instruccions de funcionament

Once properly installed and primed, the Red Lion RL-SPRK100 Sprinkler Pump is ready for operation. Ensure all connections are tight and there are no obstructions in the intake or discharge lines.

3.1 Engegada de la bomba

Activate the power supply to the pump. The pump will begin to draw water and build pressure. Monitor the system for any unusual noises or leaks during initial startup.

Red Lion RL-SPRK100 Sprinkler Pump in operation

Image 3.1: The Red Lion Sprinkler Pump operating in a residential setting, drawing water from a well, lake, pond, or ditch for irrigation.

3.2 Pautes de rendiment

The pump is designed to deliver consistent water flow and pressure for various sprinkler system configurations. Refer to the performance chart below for expected output based on dynamic head and flow rate.

Red Lion Sprinkler Pump Performance Chart

Image 3.2: Performance curve chart for Red Lion Centrifugal Sprinkler Pumps, including the RL-SPRK100, showing Total Dynamic Head (ft) versus Capacity (US gpm).

3.3 Apagat de la bomba

To turn off the pump, deactivate the power supply. If the pump will be inactive for an extended period or during freezing temperatures, follow the maintenance guidelines for winterization.

4. Manteniment

Regular maintenance ensures the longevity and optimal performance of your Red Lion RL-SPRK100 Sprinkler Pump.

4.1 Comprovacions rutinàries

  • Inspect the pump and plumbing for leaks, especially at connections.
  • Check for unusual noises or vibrations during operation, which may indicate a problem.
  • Ensure the pump's ventilation openings are clear of debris to prevent overheating.

4.2 Hivernització

In regions subject to freezing temperatures, it is crucial to properly winterize the pump to prevent damage:

  1. Desconnecteu l'alimentació de la bomba.
  2. Drain all water from the pump casing traient el tap de drenatge.
  3. Disconnect the intake and discharge pipes and drain them thoroughly.
  4. Store the pump in a dry, frost-free location if possible. If not, ensure all water is completely removed and consider using RV antifreeze in the pump casing if recommended by a professional.

5. Solució De Problemes

This section provides general guidance for common issues. For complex problems, consult a qualified technician or contact Red Lion customer support.

5.1 La bomba no arrenca

  • Sense energia: Check circuit breaker or fuse. Ensure power cord is securely plugged in.
  • Vol incorrectetage Configuració: Verify the pump's voltage setting matches the power supply (115V or 230V).
  • Motor Overload: Allow the motor to cool down if the thermal overload protector has tripped. Check for obstructions in the impeller.

5.2 Pump Runs But Delivers No Water or Low Pressure

  • Pèrdua de Prime: Re-prime the pump as described in Section 2.2. Check for air leaks in the suction line or loose connections.
  • Clogged Intake/Impeller: Inspect the intake screen and impeller for debris.
  • Low Water Source: Ensure the water source level is adequate for the pump's suction lift capabilities.
  • Discharge Obstruction: Check for closed valves or blockages in the discharge piping or sprinkler heads.

5.3 Excessive Noise or Vibration

  • Aire al sistema: Ensure the pump is fully primed and there are no air leaks.
  • Muntatge solt: Check that the pump is securely mounted to a stable surface.
  • Foreign Object: Turn off power and inspect the impeller for any foreign objects.

6. Especificacions

Detailed technical specifications for the Red Lion RL-SPRK100 Sprinkler Pump.

Red Lion RL-SPRK100 Sprinkler Pump Dimensions

Image 6.1: Technical drawing illustrating the dimensions of the SPRK Series Sprinkler Pumps, including height (A), length (B), and width (C).

EspecificacióValor
MarcaRed Lion
Número de model97101001
Cavalls de força1 CV
Voltage115/230 volts
Wattage4848 watts
Caudal màxim63 galons per minut (GPM)
Pressió màxima45 PSI
Alçada màxima d'elevació25 peus
Intake Thread SizeNPT femella d'2 polzada
Discharge Thread SizeNPT femella d'1.5 polzada
MaterialCast Iron, Thermoplastic
Dimensions del producte (L x A x A)21.85" x 11.42" x 10.2"
Pes de l'article53 lliures
Font d'alimentacióElèctric amb cable
Components inclososPump with thermoplastic impeller
UPC010121124868, 010121001398

7. Garantia i Suport

7.1 Garantia del fabricant

The Red Lion RL-SPRK100 Sprinkler Pump is covered by a Garantia del fabricant de 2 anys. Please retain your proof of purchase for warranty claims. For specific terms and conditions, refer to the warranty information provided with your product packaging.

7.2 Suport tècnic

For technical assistance, troubleshooting guidance, or questions regarding your Red Lion product, please contact our support team:

  • Telèfon d'assistència tècnica: 1-888-885-9254

Our staff are available to assist with troubleshooting or installation assistance.

Documents relacionats - 97101001

Preview Red Lion RL-SPRK Series Sprinkler Pump Owner's Manual - Installation, Operation, Maintenance Guide
This manual provides comprehensive instructions for the Red Lion RL-SPRK Series Sprinkler Pumps, covering installation, voltage settings, operation, maintenance, troubleshooting, and replacement parts. Designed for residential and commercial lawn and turf sprinkler systems.
Preview Red Lion Pump Troubleshooting Guide: Solutions for Jet, Submersible, and Transfer Pumps
Comprehensive troubleshooting guide for Red Lion water pumps, including Shallow Well Jet Pumps (e.g., RJS-50-PREM), Convertible Jet Pumps (e.g., RJC-50), 4" Submersible Well Pumps (e.g., RL12G10-3W2V), Submersible Utility & Sump Pumps, RL-S Cast Iron Surface Effluent Pumps, RL-50 Transfer Pumps, and RLSP/RLHE Sprinkler Pumps. Find solutions for common issues like motor failure, priming problems, low pressure, and more.
Preview Red Lion RLHE-300 Cast Iron Industrial Sprinkler Pump Owner's Manual
Comprehensive owner's manual for the Red Lion RLHE-300 industrial sprinkler pump, covering installation, operation, maintenance, and troubleshooting. Features include heavy-duty iron casing, high-efficiency impeller, and automatic thermal protector.
Preview Red Lion CUB5 Miniature Electronic 8-Digit Dual Counter and Rate Indicator
Detailed specifications, installation guide, and programming manual for the Red Lion CUB5 miniature electronic 8-digit dual counter and rate indicator. Features include selectable LCD or LED backlighting, optional relay and serial communication modules, and NEMA 4X/IP65 sealing.
Preview Red Lion RJSE-75SS Sprinkler Utility Pump - Operation and Maintenance Manual
Comprehensive guide for the Red Lion RJSE-75SS Sprinkler Utility Pump, covering safety warnings, electrical precautions, application, installation, operation, maintenance, and troubleshooting. Includes detailed diagrams and warranty information.
Preview Red Lion RL-MP25A Utility Pump Owner's Manual and Specifications
Comprehensive owner's manual for the Red Lion RL-MP25A Utility Pump, detailing specifications, safety instructions, installation, operation, maintenance, and troubleshooting. Includes flow rate charts and technical data.