Red Lion RL-WC50TA

Red Lion RL-WC50TA Cast Iron Sewage Pump User Manual

Model: RL-WC50TA (Part Number: 14942748)

1. Introducció

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Red Lion RL-WC50TA Cast Iron Sewage Pump. Please read all instructions carefully before use to ensure proper function and longevity of the product.

The Red Lion RL-WC50TA is a robust 1/2 HP submersible pump designed for high-volume transfer of sewage or effluent. It is capable of handling semi-solids up to 2 inches in diameter, making it suitable for applications such as basement washrooms, sewage systems, or holding tanks. This pump is equipped with a piggyback tethered float switch for automatic operation.

Important: This pump is not recommended for pond use.

2. Informació de seguretat

Always prioritize safety during installation, operation, and maintenance. Failure to follow safety guidelines can result in serious injury or property damage.

  • Seguretat elèctrica: Ensure the power supply matches the pump's requirements (115 Volts). Always disconnect power before servicing the pump. Use a ground fault circuit interrupter (GFCI) for electrical connections.
  • Equips de protecció individual (EPI): Wear appropriate PPE, including gloves and eye protection, when handling the pump or working with wastewater.
  • Instal·lació correcta: Install the pump according to local plumbing and electrical codes. Ensure the pump is placed on a solid, level surface in the basin.
  • Materials perillosos: Be aware that sewage and effluent contain hazardous biological materials. Avoid direct contact and ensure proper disposal.
  • Nens i animals de companyia: Keep children and pets away from the pump and installation area.

3. Producte acabatview

The Red Lion RL-WC50TA is engineered for durability and reliable performance in demanding wastewater applications.

Red Lion RL-WC50TA Cast Iron Sewage Pump

Figure 1: Red Lion RL-WC50TA Cast Iron Sewage Pump with tethered float switch.

Característiques principals:

  • Construcció resistent: Cast iron housing and vortex-style impeller for durability and efficient solids handling.
  • Manipulació de sòlids: Capable of passing semi-solids up to 2 inches in diameter, preventing clogs.
  • Funcionament automàtic: Piggyback tethered float switch for automatic activation and deactivation based on water levels.
  • Protecció del motor: 1/2 HP PSC dual bearing motor with thermal overload protection for extended life.
  • CSA Listed: Certified for safety in both USA and Canada.

Components interns:

Diagram of Red Lion RL-WC50TA internal components

Figure 2: Diagram illustrating the internal components of the RL-WC50TA, including the 1/2 HP high-efficiency PSC motor with thermal overload protection, dual ball bearings, cast iron housing, stainless steel rotor shaft, cast iron vortex style impeller, and 2-inch FNPT threaded discharge.

4. Configuració i instal·lació

Proper installation is critical for the performance and safety of your sewage pump. If you are unsure about any step, consult a qualified professional.

Llista de verificació prèvia a la instal·lació:

  • Verifiqueu la font d'alimentació (115 volts).
  • Assegureu-vos que la basin diameter is at least 18 inches.
  • Gather necessary tools and plumbing fittings (2-inch FNPT discharge).
  • Confirm the installation area is clear and accessible.

Passos d'instal·lació:

  1. Prepare the Basin: Assegureu-vos que el càrter basin is clean and free of debris. The pump should rest on a solid, level surface at the bottom of the basin.
  2. Connecteu la canonada de descàrrega: Attach a 2-inch FNPT discharge pipe to the pump outlet. Use appropriate sealant or tape to ensure a watertight connection.
  3. Instal·leu la vàlvula antiretorn: Install a check valve in the discharge line above the pump to prevent backflow of water into the basin.
  4. Posició de la bomba: Carefully lower the pump into the basin. Ensure the float switch can move freely without obstruction from the pump, basin walls, or piping.
  5. Connexió elèctrica: Connect the pump's 10-ft. power cord to a dedicated 115 Volt, GFCI-protected outlet. The piggyback plug allows for automatic or manual operation.

Understanding Pump Types (Video):

For a better understanding of different pump types and their applications, including sewage and effluent pumps, please watch the following informational video:

Video 1: This video explains the differences between sump, sewage, effluent, and utility pumps, helping users understand the correct application for each type. Provided by Franklin Electric - Little Giant.

5. Instruccions de funcionament

The Red Lion RL-WC50TA operates automatically via its tethered float switch. It can also be manually tested.

Funcionament automàtic:

  • The pump will activate when the water level reaches approximately 17.5 inches.
  • The pump will continue to run until the water level falls to approximately 7.5 inches, at which point it will shut off.
  • Ensure the float switch has a clear path of travel and is not restricted by any objects in the basin.
Red Lion RL-WC50TA automatic operation with piggyback float switch

Figure 3: Illustration of the piggyback float switch and its activation/deactivation levels for automatic operation. The piggyback plug allows for switching to manual mode for testing or maintenance.

Manual Operation/Testing:

The piggyback plug design allows for manual testing of the pump. To operate manually, simply unplug the float switch plug from the wall outlet, then plug the pump's main power cord directly into the wall outlet. The pump will run continuously. To return to automatic operation, unplug the pump's main power cord and re-insert the float switch plug into the wall outlet.

Caution: Do not run the pump dry for extended periods in manual mode, as this can cause damage.

6. Manteniment

Un manteniment regular garanteix un rendiment òptim i allarga la vida útil de la bomba.

  • Inspecció mensual: Check the sump basin for excessive debris. Remove any large objects that could obstruct the float switch or pump intake.
  • Float Switch Check: Periodically test the float switch by manually raising it to ensure the pump activates and deactivates correctly.
  • Impulsor net: If the pump's performance decreases, disconnect power and inspect the impeller for clogs or buildup. Clean as necessary.
  • Inspecció del cable d'alimentació: Examine the power cord for any signs of damage, fraying, or wear. Replace if damaged.
  • Hivernització (si escau): Si la bomba es troba en una zona amb temperatures de congelació i no s'utilitzarà, traieu-la de la base.asin, clean it thoroughly, and store it in a dry, frost-free location.

7. Solució De Problemes

Consulteu la taula següent per veure els problemes habituals i les seves possibles solucions.

ProblemaCausa possibleSolució
La bomba no funcionaNo power; tripped breaker; faulty float switch; clogged impellerCheck power supply and breaker; test float switch; clear impeller
La bomba funciona contínuamentFloat switch stuck in ON position; faulty float switchCheck float switch for obstructions; replace float switch if faulty
Pump runs but no water is dischargedClogged intake or discharge pipe; air lock; low water levelClear clogs; prime pump if air locked; ensure sufficient water level
La bomba circula amb massa freqüènciaBasin too small; check valve not holding; float switch differential too narrowConsult a professional for basin size; inspect/replace check valve; adjust float switch if possible (refer to specifications)

8. Especificacions

Detailed technical specifications for the Red Lion RL-WC50TA Sewage Pump.

Red Lion RL-WC50TA Dimensions Diagram

Figure 4: Dimensions diagram for the Red Lion RL-WC50TA Sewage Pump. Height (A): 15.8" (401 mm), Length (B): 9" (229 mm), Width (C): 6" (152 mm), Weight: 30 lbs (13.6 kg).

EspecificacióValor
ModelRL-WC50TA
Número de part14942748
MarcaRed Lion
Potència (HP)0.5 (1/2 CV)
Voltage115 Volts
Ampedat9 Amps
Wattage950 watts
Caudal màxim5600 GPH (93 galons per minut)
Alçada màxima d'elevació (tancament)22 peus
Mida de descàrregaFNPT de 2 polzades
Manipulació de sòlidsUp to 2-inch diameter semi-solids
Tipus d'interruptor de flotadorPiggyback Tethered
Float Switch ON Level17.5 polzades
Float Switch OFF Level7.5 polzades
Longitud del cable d'alimentació10 peus
Mínim Basin Diàmetre18 polzades
MaterialFerro colat
Dimensions del producte (L x A x A)9" x 6" x 15.8"
Pes de l'article29.8 lliures
Red Lion RL-WC50TA Performance Curve and Table

Figure 5: Performance curve and table for the Red Lion RL-WC50TA, showing Gallons Per Hour (GPH) at various lift heights and the shut-off point.

9. Garantia

The Red Lion RL-WC50TA Sewage Pump comes with a Garantia del fabricant de 2 anys. Please retain your proof of purchase for warranty claims. For specific terms and conditions, refer to the warranty documentation included with your product or contact Red Lion customer support.

10. Suport

For technical assistance, product inquiries, or warranty support, please contact Red Lion customer service. You can also visit the official Red Lion weblloc per a recursos addicionals i preguntes freqüents.

  • Red Lion Weblloc: Visit the Red Lion Store on Amazon
  • Suport tècnic: Refer to your product packaging or the Red Lion weblloc web per obtenir la informació de contacte més actualitzada.

Documents relacionats - RL-WC50TA

Preview Red Lion RLWA Series Sewage Pumps Owner's Manual
Official owner's manual for Red Lion RLWA Series sewage pumps, including models RL50WA and RL75WA. Provides detailed information on installation, operation, safety guidelines, maintenance, troubleshooting, and warranty.
Preview Red Lion Pump Troubleshooting Guide: Solutions for Jet, Submersible, and Transfer Pumps
Comprehensive troubleshooting guide for Red Lion water pumps, including Shallow Well Jet Pumps (e.g., RJS-50-PREM), Convertible Jet Pumps (e.g., RJC-50), 4" Submersible Well Pumps (e.g., RL12G10-3W2V), Submersible Utility & Sump Pumps, RL-S Cast Iron Surface Effluent Pumps, RL-50 Transfer Pumps, and RLSP/RLHE Sprinkler Pumps. Find solutions for common issues like motor failure, priming problems, low pressure, and more.
Preview Red Lion RL-SPRK Series Sprinkler Pump Owner's Manual - Installation, Operation, Maintenance Guide
This manual provides comprehensive instructions for the Red Lion RL-SPRK Series Sprinkler Pumps, covering installation, voltage settings, operation, maintenance, troubleshooting, and replacement parts. Designed for residential and commercial lawn and turf sprinkler systems.
Preview Red Lion RL-MP25A Utility Pump Owner's Manual and Specifications
Comprehensive owner's manual for the Red Lion RL-MP25A Utility Pump, detailing specifications, safety instructions, installation, operation, maintenance, and troubleshooting. Includes flow rate charts and technical data.
Preview Red Lion 4-Inch Deep Well Submersible Pump Owner's Manual & Installation Guide
Comprehensive guide for Red Lion 4-inch deep well submersible pumps (RL-series and RS-series), covering specifications, safety, installation, maintenance, and troubleshooting for rural water supply. Includes model details, electrical requirements, and operational advice.
Preview Red Lion CUB5 Miniature Electronic 8-Digit Dual Counter and Rate Indicator
Detailed specifications, installation guide, and programming manual for the Red Lion CUB5 miniature electronic 8-digit dual counter and rate indicator. Features include selectable LCD or LED backlighting, optional relay and serial communication modules, and NEMA 4X/IP65 sealing.