1. Introducció
This manual provides important instructions for the safe installation, operation, and maintenance of the SIEMENS BQ3B040 40-Amp Three Pole 240-Volt Circuit Breaker. The Siemens Type BQ Circuit Breaker is a cable-in, cable-out, non-interchangeable trip molded case circuit breaker designed for reliable electrical protection. It is rated for 40 Amps, 240 Volts, and has a 10KAIC interrupting rating.
Si us plau, llegiu aquest manual detingudament abans d'intentar qualsevol instal·lació o operació. Conserveu aquest manual per a futures consultes.

Un clar view of the SIEMENS BQ3B040 circuit breaker, showing its compact design and terminal lugs.
2. Informació de seguretat
ADVERTIMENT: Electrical shock hazard. Can cause serious injury or death. Installation and servicing of this circuit breaker must be performed by qualified, licensed electrical personnel only. Always disconnect power at the main service panel before working on or near electrical equipment.
- Always follow all local and national electrical codes.
- Ensure the power supply is completely de-energized and locked out before beginning any work.
- Utilitzeu l'equip de protecció individual (EPI) adequat, incloent-hi guants aïllants i ulleres de seguretat.
- Never attempt to modify the circuit breaker.
- Do not install a circuit breaker that appears damaged.
3. Contingut del paquet
El paquet normalment inclou:
- One (1) SIEMENS BQ3B040 40-Amp Three Pole 240-Volt Circuit Breaker
4. Configuració i instal·lació
IMPORTANT: La instal·lació ha de ser realitzada per un electricista qualificat d'acord amb tots els codis i normes elèctriques aplicables.
- Desconnexió d'alimentació: Ensure all power to the electrical panel is turned OFF at the main disconnect and verified with a voltage tester. Lock out and tag out the main disconnect.
- Accés al panell: Traieu amb cura la coberta del quadre elèctric.
- Col·locació de l'interruptor: Identify the appropriate slot in the panel for a three-pole breaker.
- Connexió: Connect the load wires to the designated terminals on the circuit breaker. The BQ3B040 is a lug-out breaker, meaning wires connect directly to the lugs. Ensure all connections are tight and secure, adhering to torque specifications if provided on the breaker or panel.
- Muntatge: Snap the circuit breaker firmly into place on the bus bar. Ensure it is fully seated.
- Remuntatge del panell: Substituïu la coberta del quadre elèctric.
- Restauració d'energia: Restableix l'alimentació al quadre de servei principal.
5. Instruccions de funcionament
The SIEMENS BQ3B040 circuit breaker operates as a protective device for your electrical circuit. It has three primary states:
- ACTIVITAT: In this position, power is flowing through the circuit breaker to the connected load.
- DESACTIVAT: In this position, power to the connected load is interrupted.
- ENTROPELLAT: If an overload or short circuit occurs, the breaker will automatically move to a tripped position (often midway between ON and OFF, or fully OFF depending on the design). This indicates a fault in the circuit.
To reset a tripped breaker, first move the handle firmly to the OFF position, then push it to the ON position. If the breaker immediately trips again, do not attempt to reset it repeatedly. Investigate the cause of the fault.
6. Manteniment
Els interruptors automàtics generalment requereixen un manteniment mínim. Tanmateix, es recomana una inspecció periòdica:
- Inspecció visual: Anualment, o segons ho exigeixin les normes locals, feu que un electricista qualificat inspeccioni l'interruptor i les seves connexions per detectar qualsevol signe de sobreescalfament, cables solts o danys físics.
- Neteja: Ensure the area around the circuit breaker is free from dust and debris. Do not use liquids for cleaning inside the electrical panel.
- Prova: Do not attempt to test the tripping mechanism yourself. This should only be done by qualified professionals using specialized equipment.
7. Solució De Problemes
If you experience issues with your circuit breaker, consider the following:
- Freqüència de salts de l'interruptor: This indicates an overload or a short circuit on the protected circuit. Disconnect some appliances or devices from the circuit, or inspect for damaged wiring. If the problem persists, consult a qualified electrician.
- Breaker Will Not Reset: If the breaker immediately trips after being reset, a persistent fault (overload or short circuit) is present. Do not force the breaker.
- Sense alimentació al circuit: Check if the breaker is in the OFF or TRIPPED position. If it is ON and there is still no power, check other breakers or consult an electrician.
For any persistent or complex electrical issues, always contact a qualified electrician.
8. Especificacions
| Característica | Especificació |
|---|---|
| Marca | SIEMENS |
| Número de model | BQ3B040 |
| Valoració actual | 40 Amps |
| Voltage | 240 Volts |
| Nombre de pols | 3 |
| Tipus d'interruptor | Standard, Thermal-Magnetic |
| Tipus de muntatge | Muntanya de pols |
| Interrupció de la qualificació | 10KAIC |
| Dimensions del producte | 30 "P x 8" W x 6" H |
| Pes de l'article | 10.7 unces |
| Material | Vidre |
| Components inclosos | BQ3B040 |
9. Garantia i Suport
Siemens recomana fermament no utilitzar interruptors "usats". La instal·lació d'interruptors usats en un quadre Siemens anul·larà la garantia del quadre. Siemens no ven interruptors usats i no ha aprovat cap venedor extern per fer-ho.
For technical support, warranty claims, or further assistance, please contact Siemens customer service or visit the official Siemens website. Always refer to your purchase documentation for specific warranty terms and conditions.
Recursos en línia: Visit the SIEMENS Store on Amazon