ACI 82293

ACI 82293 Power Window Motor and Regulator Assembly User Manual

1. Introducció

This manual provides essential information for the proper installation, operation, and maintenance of your ACI 82293 Power Window Motor and Regulator Assembly. ACI power window motors are engineered to meet or exceed original equipment performance standards, ensuring quality, durability, and reliability. This assembly includes original equipment style connectors for seamless integration.

Les característiques principals d'aquest producte inclouen:

  • Engineered to match original equipment regulator mounting points.
  • Designed for advanced torque and speed performance.
  • Integrated circuit breaker to prevent overheating.
  • Constructed with hardened steel gears for enhanced durability.
ACI 82293 Power Window Motor and Regulator Assembly

Figure 1: ACI 82293 Power Window Motor and Regulator Assembly. This image displays the complete assembly, including the metal track, cables, motor, and electrical connector, ready for installation.

2. Configuració i instal·lació

Installation of the ACI 82293 Power Window Motor and Regulator Assembly requires mechanical aptitude and basic automotive tools. It is recommended that installation be performed by a qualified technician. Always refer to your vehicle's specific service manual for detailed instructions regarding panel removal and component access.

2.1 Precaucions de seguretat

  • Disconnect the vehicle's battery before beginning any electrical work to prevent accidental power surges or short circuits.
  • Utilitzeu l'equip de protecció individual adequat, incloent-hi ulleres i guants de seguretat.
  • Ensure the window glass is properly supported during removal and installation to prevent breakage or injury.

2.2 Passos generals d'instal·lació

  1. Carefully remove the interior door panel and any other components obstructing access to the old window regulator.
  2. Disconnect the electrical connector from the old window motor.
  3. Unbolt and remove the old window regulator assembly from the door frame. Note the mounting points and orientation.
  4. Attach the window glass to the new ACI 82293 regulator assembly, ensuring it is securely fastened.
  5. Mount the new regulator assembly into the door frame, aligning it with the original mounting points. Secure all bolts.
  6. Connect the electrical connector of the new motor to the vehicle's wiring harness.
  7. Torneu a connectar la bateria del vehicle.
  8. Test the window's operation (up and down) to ensure smooth movement and proper alignment before reassembling the door panel.
  9. Reinstall the interior door panel and any other removed components.

3. Instruccions de funcionament

Once installed, the ACI 82293 Power Window Motor and Regulator Assembly operates in conjunction with your vehicle's existing power window switch. Pressing the switch in the 'up' or 'down' direction will activate the motor, causing the window glass to move accordingly. Ensure no obstructions are present in the window path during operation.

4. Manteniment

The ACI 82293 Power Window Motor and Regulator Assembly is designed for long-term, maintenance-free operation. However, periodic checks can help ensure optimal performance:

  • Inspect Window Seals: Ensure window seals are clean and free of debris. Worn or dirty seals can increase friction, putting strain on the motor.
  • Lubricació: If the window movement becomes stiff, a silicone-based lubricant can be applied to the window tracks and rubber seals. Avoid petroleum-based lubricants as they can damage rubber components.
  • Connexions elèctriques: Periodically check the electrical connector for corrosion or looseness.

5. Solució De Problemes

Si teniu problemes amb l'elevador de finestres elèctric, tingueu en compte els passos habituals següents per resoldre problemes:

  • La finestra no es mou:
    • Check the vehicle's fuse box for a blown fuse related to the power windows.
    • Verify that the electrical connector to the motor is securely attached.
    • Test the power window switch. A faulty switch can prevent the motor from receiving power.
  • La finestra es mou lentament o de manera brusca:
    • Inspect window tracks and seals for obstructions or excessive friction. Clean and lubricate as necessary.
    • Check for any binding in the regulator mechanism.
  • Sorolls de grinyols o clics:
    • This may indicate an issue with the gears in the motor or the regulator mechanism. Professional inspection is recommended.

Si aquests passos no resolen el problema, pot ser necessari un diagnòstic i una reparació professionals.

6. Especificacions

FabricantACI
MarcaACI
Número de model82293
Pes de l'article3.7 lliures
Dimensions del producte2.4 x 10.6 x 24 polzades
Acabat exteriorMecanitzat
Número de peça del fabricant82293
ASINB006OVT8LQ
Data de primera disponibilitat22 de desembre de 2011

Què hi ha a la caixa: Main component only (ACI 82293 Power Window Motor and Regulator Assembly).

7. Informació de la garantia

Specific warranty details for the ACI 82293 Power Window Motor and Regulator Assembly are not provided within this manual. Please refer to the product packaging, your purchase receipt, or contact ACI customer support for comprehensive warranty information.

8. Suport

For technical assistance, installation questions, or further product information, please contact ACI customer support. Contact details are typically available on the product packaging or the official ACI weblloc.

Documents relacionats - 82293

Preview Guia d'instal·lació dels aires condicionats de casset de la sèrie ACI
Instruccions d'instal·lació detallades per als aparells d'aire condicionat de cassette de la sèrie ACI, incloent-hi les precaucions de seguretat, les dimensions de muntatge i els procediments de connexió. Cobreix models com ACI-25HRDC1C, ACI-35HRDC1C, ACI-53HRDC1C, ACI-71HRDC1A, ACI-105HRDC3A, ACI-140HRDC3A i ACI-180HRDC3A.
Preview ACI Duct Humidity Temperature Transmitter Series Sensor Installation and Operation
Installation and operation instructions for ACI's Duct Humidity Temperature Transmitter Series Sensors (A/TT and A/RH). Covers general information, mounting, wiring, calibration, troubleshooting, and product specifications for HVAC building management systems.
Preview ACI Averaging Series Temperature Transmitter: Installation and Operation Guide
Comprehensive user's guide for the ACI Averaging Series Temperature Transmitter, detailing installation, operation, wiring, troubleshooting, and product specifications. Includes essential information for proper setup and maintenance.
Preview ACI BACnet/Modbus Room Series Sensor Installation and Operation Manual
Comprehensive installation and operation guide for the ACI BACnet MS/TP and Modbus RTU Room Series temperature and humidity sensors. Covers wiring, mounting, configuration, and specifications for building management systems.
Preview ACI RR2552 Spread Spectrum Repeater: Installation and Operation Instructions
Comprehensive guide to installing and operating the ACI RR2552 Spread Spectrum Repeater, covering setup, network ID configuration, mounting, wiring, troubleshooting, and product specifications.
Preview ACI Mini Adjustable Status Switch Series A/MCS-A, A/MSCS-A Installation and Operation Manual
Installation and operation instructions for the ACI Mini Adjustable Status Switch Series (A/MCS-A, A/MSCS-A). Covers features, precautions, mounting, wiring, calibration, troubleshooting, and product specifications for AC current monitoring.